These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 1498550)

  • 1. Blood component processing technique and plasma quality.
    Suontaka AM; Bremme K; Akerblom O; Blombäck M
    Infusionsther Transfusionsmed; 1992 Jun; 19(3):110-4. PubMed ID: 1498550
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quality of plasma separated from (buffy coat + plasma). An alternative way of blood processing.
    Rácz Z; Baróti C; Hidvégi T; Skopál J; Thék M
    Acta Haematol Pol; 1994; 25(1):47-53. PubMed ID: 8209614
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Blood fractionation based on the extraction of the buffy-coat layer. Analysis of our results].
    Algora M; Torres P; Rodríguez MA; de la Calle C; Biurrún M; Nieto S; Ruiz M; Alonso MV
    Sangre (Barc); 1995 Apr; 40(2):91-6. PubMed ID: 7784953
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Analysis of the quality of hemoderivatives obtained using a buffy-coat extraction system with a top-and-bottom technique (Optipress II)].
    Hurtado C; Bonanad S; Soler MA; Mirabet V; Blasco I; Planelles MD; de Miguel A
    Sangre (Barc); 1999 Oct; 44(5):319-26. PubMed ID: 10618907
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [A new multiple blood bag system with top and bottom drainage. Comparison with the conventional multiple bag system].
    Pietersz RN; Dekker WJ; Reesink HW
    Beitr Infusionsther; 1990; 26():60-4. PubMed ID: 1703902
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Preparation of leukocyte-poor thrombocyte concentrates from buffy coat by using a new quadruple bag system].
    Misterek J; Müller K; Bux J; Mueller-Eckhardt C
    Beitr Infusionsther; 1990; 26():96-8. PubMed ID: 1703911
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technical aspects of buffy coat removal from whole blood and those of platelet production from single buffy coat units.
    Rácz Z; Baróti C
    Biomed Tech (Berl); 1993 Nov; 38(11):266-9. PubMed ID: 8123765
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improvement of the separation of blood by modification of separators Optipress and Biotrans Separator.
    Kretschmer V; Tesche U; Richter P
    Beitr Infusionsther; 1992; 30():112-21. PubMed ID: 1284685
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Method for processing leukocyte- and platelet-poor red cells in closed bags.
    Shimizu T; Ishikawa Y; Tsurumi H; Hibi S; Takakura R; Morishima Y; Hasegawa I; Goto S
    Vox Sang; 1986; 50(4):203-7. PubMed ID: 3727490
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improvement of blood component quality--automatic separation of blood components in a new bag system.
    Kretschmer V; Khan-Blouki K; Biermann E; Söhngen D; Eckle R
    Infusionstherapie; 1988 Dec; 15(6):232-9. PubMed ID: 3235201
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Differences in residual white blood cell subset counts in buffy coat-depleted red cell concentrates prepared with bottom and top or quadruple-bag systems.
    de Wildt-Eggen J; Schrijver JG; Kuiper-Kramer PA; Bins M; van Prooijen HC
    Vox Sang; 1999; 77(2):97-102. PubMed ID: 10516554
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Current methods in blood preservation: recovery of blood components using a multi-bag system].
    Bergmann H; Blauhut B; Gassner W; Haider M
    Wien Med Wochenschr; 1991; 141(21):485-92. PubMed ID: 1781176
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quality analysis of blood components obtained by automated buffy-coat layer removal with a top & bottom system (Optipress (R)II).
    Hurtado C; Bonanad S; Soler Mf; Mirabet V; Blasco I; Planelles Mf; De Miguel A
    Haematologica; 2000 Apr; 85(4):390-5. PubMed ID: 10756365
    [TBL] [Abstract][Full Text] [Related]  

  • 14. New closed system using a sterile connection device and preconnected PRP pack for extended storage of apheresis platelet products.
    Shimizu T; Kouketsu K; Morishima Y; Hasegawa I; Kamiya T
    Tohoku J Exp Med; 1988 Jul; 155(3):303-4. PubMed ID: 3176024
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automated separation of whole blood in top and bottom bags into components using the Compomat G4.
    van der Meer P; Pietersz R; Hinloopen B; Dekker W; Reesink H
    Vox Sang; 1999; 76(2):90-9. PubMed ID: 10085525
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Separation of platelet concentrates (PC) from buffy coat (BC) using the bottom and top drainage (BAT) system.
    Kretschmer V; Biermann E; Loh H
    Beitr Infusionsther; 1990; 26():65-70. PubMed ID: 1703903
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated blood component preparation with the Opti system: three years' experience.
    Högman CF; Eriksson L; Ring M
    Beitr Infusionsther; 1992; 30():100-7. PubMed ID: 1284683
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Evaluation of platelet quality obtained using conventional methods or from buffy-coat and stored at room temperature].
    Dzieciatkowska A; Fuskiewicz M; Ziemba-Zółowska B; Sabliński J
    Acta Haematol Pol; 1994; 25(2):135-43. PubMed ID: 8067184
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of changes in plasma hemoglobin and potassium levels in red cell units during processing and storage.
    Saini N; Basu S; Kaur R; Kaur J
    Transfus Apher Sci; 2015 Jun; 52(3):319-25. PubMed ID: 25665725
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Procedure for production of leukocyte depleted erythrocyte and thrombocyte concentrates (PRP method) using top and bottom bags, Optipress automated separators and a computer controlled Cryofuge 6000].
    Aulmann M; Ullrich R; Iber B; Neppert J
    Beitr Infusionsther; 1992; 30():122-6. PubMed ID: 1284686
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.