These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 14987642)

  • 21. Non-destructive method of characterisation of radioactive waste containers using gamma spectroscopy and Monte Carlo techniques.
    Ridikas D; Feray S; Cometto M; Damoy F
    Radiat Prot Dosimetry; 2005; 115(1-4):113-6. PubMed ID: 16381694
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Optimization of counting times for short-lived gamma-ray emitters in air filter samples.
    Korun M
    Appl Radiat Isot; 2006; 64(10-11):1329-32. PubMed ID: 16554169
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Half-life measurements with ionization chambers--a study of systematic effects and results.
    Schrader H
    Appl Radiat Isot; 2004; 60(2-4):317-23. PubMed ID: 14987661
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The interplay between the statistical correlations of gamma-ray emission probabilities and efficiency calibration.
    Castro RM; Vanin VR; Helene O; Pascholati PR; Maidana NL; Dias MS; Koskinas MF
    Appl Radiat Isot; 2004; 60(2-4):185-90. PubMed ID: 14987640
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Gamma-ray spectrometry of radon in water and the role of radon to representatively sample aquifers.
    Talha SA; Lindsay R; Newman RT; de Meijer RJ; Maleka PP; Hlatshwayo IN; Mlwilo NA; Mohanty AK
    Appl Radiat Isot; 2008 Nov; 66(11):1623-6. PubMed ID: 18515121
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The validity of the virtual point detector concept for absorbing media.
    Presler O; German U; Pelled O; Alfassi ZB
    Appl Radiat Isot; 2004; 60(2-4):213-6. PubMed ID: 14987645
    [TBL] [Abstract][Full Text] [Related]  

  • 27. On-site gamma-ray spectroscopic measurements of fission gas release in irradiated nuclear fuel.
    Matsson I; Grapengiesser B; Andersson B
    Appl Radiat Isot; 2007 Jan; 65(1):36-45. PubMed ID: 16949295
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Crystal rounding and the efficiency transfer method in gamma-ray spectrometry.
    Vidmar T; Gasparro J
    Appl Radiat Isot; 2009 Nov; 67(11):2057-61. PubMed ID: 19679487
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Influence of the background approximation methods on the analysis of gamma-ray spectra.
    Luca A; Morel J
    Appl Radiat Isot; 2004; 60(2-4):233-7. PubMed ID: 14987649
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A method for the comparison of performance of gamma-ray spectrometry calibration cocktails.
    Legarda F; Los Arcos JM; Herranz M
    Appl Radiat Isot; 2004; 60(2-4):547-51. PubMed ID: 14987701
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Fast and accurate approach to gamma-spectrum modelling: a validation study with a shielded/unshielded voluminous uranium sample.
    Berlizov AN; Mayer K
    Appl Radiat Isot; 2010 Sep; 68(9):1822-31. PubMed ID: 20385501
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Secondary standardisation of 95mTc.
    Harms AV; Baker M; Jerome SM; Pearce AK; Woods MJ; Woods SA
    Appl Radiat Isot; 2004; 60(2-4):553-5. PubMed ID: 14987702
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Correction for decay during counting in gamma spectrometry.
    Nir-El Y
    Radiat Prot Dosimetry; 2013 Mar; 153(3):400-1. PubMed ID: 22719043
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Study of XK and gamma photon emission following decay of 154Eu.
    Terechtchenko E; Rasko M; Sepman S; Zanevsky A; Tuan AT; Amiot MN; Bobin C; Morel J
    Appl Radiat Isot; 2004; 60(2-4):329-36. PubMed ID: 14987663
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement of peak and total efficiencies of low-energy gamma-ray detectors with sources emitting photons in cascade.
    Korun M
    Appl Radiat Isot; 2004; 60(2-4):207-11. PubMed ID: 14987644
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Half-life measurement of 95mTc--refinement in the uncertainty value.
    Catterson T; Van Dalsem DJ
    Appl Radiat Isot; 2006; 64(10-11):1425-7. PubMed ID: 16549357
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Development and application of Marinelli beaker standards for monitoring radioactivity in Dairy-Products by gamma-ray spectrometry.
    Lavi N; Alfassi ZB
    Appl Radiat Isot; 2004 Dec; 61(6):1437-41. PubMed ID: 15388145
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Primary standardization of 72Ga.
    Koskinas MF; Moreira DS; Takeda MN; Antônio Seneda J; Dias MS
    Appl Radiat Isot; 2006; 64(10-11):1225-8. PubMed ID: 16556502
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Measurements of short-lived cosmic-ray-produced radionuclides in rainwater.
    Komura K; Kuwahara Y; Abe T; Tanaka K; Murata Y; Inoue M
    J Environ Radioact; 2007; 96(1-3):103-9. PubMed ID: 17428591
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A semi-empirical approach for determination of low-energy gamma-emmiters in sediment samples with coaxial Ge-detectors.
    San Miguel EG; Perez-Moreno JP; Bolivar JP; García-Tenorio R
    Appl Radiat Isot; 2004; 61(2-3):361-6. PubMed ID: 15177372
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.