281 related articles for article (PubMed ID: 14987662)
1. Ionization chamber measurements of the half-lives of 24Na, 42K, 76As and 198Au.
Unterweger MP; Lindstrom RM
Appl Radiat Isot; 2004; 60(2-4):325-7. PubMed ID: 14987662
[TBL] [Abstract][Full Text] [Related]
2. Half-life measurements with ionization chambers--a study of systematic effects and results.
Schrader H
Appl Radiat Isot; 2004; 60(2-4):317-23. PubMed ID: 14987661
[TBL] [Abstract][Full Text] [Related]
3. Comparison of ionization chamber efficiencies for activity measurements.
Schrader H; Svec A
Appl Radiat Isot; 2004; 60(2-4):369-78. PubMed ID: 14987670
[TBL] [Abstract][Full Text] [Related]
4. Activity measurements with radionuclide calibrators in the Czech Republic.
Olsovcová V
Appl Radiat Isot; 2004; 60(2-4):535-8. PubMed ID: 14987698
[TBL] [Abstract][Full Text] [Related]
5. Activity measurement of a 176Lu sample using coincidence peaks and Monte Carlo simulations.
Jutier C; Le Petit G
Appl Radiat Isot; 2006; 64(10-11):1292-6. PubMed ID: 16603370
[TBL] [Abstract][Full Text] [Related]
6. Standardization and decay data determinations of 125I, 54Mn and 203Hg.
da Silva MA; Poledna R; Iwahara A; da Silva CJ; Delgado JU; Lopes RT
Appl Radiat Isot; 2006; 64(10-11):1440-5. PubMed ID: 16621584
[TBL] [Abstract][Full Text] [Related]
7. Calculation of 18F, 99mTc, 111In and 123I calibration factor using the penelope ionization chamber simulation method.
Amiot MN
Appl Radiat Isot; 2004; 60(2-4):529-33. PubMed ID: 14987697
[TBL] [Abstract][Full Text] [Related]
8. LSC measurements of the half-life of 40K.
Kossert K; Günther E
Appl Radiat Isot; 2004; 60(2-4):459-64. PubMed ID: 14987685
[TBL] [Abstract][Full Text] [Related]
9. Developing 152Eu into a standard for detector efficiency calibration.
Castro RM; Vanin VR; Pascholati PR; Maidana NL; Dias MS; Koskinas MF
Appl Radiat Isot; 2004; 60(2-4):283-7. PubMed ID: 14987655
[TBL] [Abstract][Full Text] [Related]
10. Standardization of 65Zn by sum-peak method.
Oliveira EM; Iwahara A; Poledna R; Delgado JU; da Silva CJ; da Silva RL; Lopes RT
Appl Radiat Isot; 2012 Sep; 70(9):2087-90. PubMed ID: 22425414
[TBL] [Abstract][Full Text] [Related]
11. Monte Carlo calculations of calibration and geometry correction factors of a radionuclide calibrator.
Olsovcová V; Havelka M
Appl Radiat Isot; 2006; 64(10-11):1370-4. PubMed ID: 16546399
[TBL] [Abstract][Full Text] [Related]
12. Half-life data--a critical review of TECDOC-619 update.
Woods MJ; Collins SM
Appl Radiat Isot; 2004; 60(2-4):257-62. PubMed ID: 14987652
[TBL] [Abstract][Full Text] [Related]
13. Standardization of a 85Sr solution by three methods.
Broda R; Dziel T; Muklanowicz A
Appl Radiat Isot; 2012 Sep; 70(9):2222-6. PubMed ID: 22425416
[TBL] [Abstract][Full Text] [Related]
14. Radioactivity measurements of 177Lu, 111In and 123I by different absolute methods.
Rezende EA; Correia AR; Iwahara A; da Silva CJ; Tauhata L; Poledna R; da Silva RL; de Oliveira EM; de Oliveira AE
Appl Radiat Isot; 2012 Sep; 70(9):2081-6. PubMed ID: 22401938
[TBL] [Abstract][Full Text] [Related]
15. An approach based on the SIR measurement model for determining the ionization chamber efficiency curves, and a study of 65Zn and 201Tl photon emission intensities.
Michotte C; Pearce AK; Cox MG; Gostely JJ
Appl Radiat Isot; 2006; 64(10-11):1147-55. PubMed ID: 16574424
[TBL] [Abstract][Full Text] [Related]
16. Unexpected bias in NIST 4πγ ionization chamber measurements.
Unterweger MP; Fitzgerald R
Appl Radiat Isot; 2012 Sep; 70(9):1892-3. PubMed ID: 22502945
[TBL] [Abstract][Full Text] [Related]
17. Comparison of radioactivity measurements with radionuclide calibrators in the Republic of Korea.
Kim GY; Lee HK; Jeong HK; Woods MJ;
Appl Radiat Isot; 2005 Aug; 63(2):201-5. PubMed ID: 15916897
[TBL] [Abstract][Full Text] [Related]
18. The coincidence-summing correction of the Compton-suppression spectrometer.
Fan YQ; Wang J; Wang SL; Zhang XJ; Li Q
Appl Radiat Isot; 2012 Sep; 70(9):2124-6. PubMed ID: 22405959
[TBL] [Abstract][Full Text] [Related]
19. Experimental verification of the half-life of 65Zn.
Van Ammel R; Pommé S; Sibbens G
Appl Radiat Isot; 2004; 60(2-4):337-9. PubMed ID: 14987664
[TBL] [Abstract][Full Text] [Related]
20. Standardization of 18F by coincidence and LSC methods.
Roteta M; García-Toraño E; Rodríguez Barquero L
Appl Radiat Isot; 2006; 64(10-11):1199-202. PubMed ID: 16580216
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]