These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

448 related articles for article (PubMed ID: 15004629)

  • 1. The value of myocardial contrast echocardiography compared with SPECT in detecting myocardial perfusion abnormalities in patients with anterior acute myocardial infarction.
    Olszowska M; Tracz W; Przewłocki T; Kostkiewicz M; Podolec P; Zalewski J; Zmudka K
    Kardiol Pol; 2004 Jan; 60(1):27-38. PubMed ID: 15004629
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Comparison of myocardial contrast echocardiography and 99mTc MIBI single photon emission computed tomography in the assessment of myocardial perfusion in patients with acute myocardial infarction].
    Olszowska M; Tracz W; Kostkiewicz M; Hlawaty M; Podolec P; Przewłocki T
    Pol Merkur Lekarski; 2006 Mar; 20(117):282-4. PubMed ID: 16780255
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Usefulness of contrast echocardiography in evaluation of myocardial reperfusion in patients with acute anterior myocardial infarction treated with PCI].
    Olszowska M; Tracz W; Kostkiewicz M; Hlawaty M; Przewłocki T; Podolec P
    Kardiol Pol; 2004 Sep; 61 Suppl 2():II19-25. PubMed ID: 20527414
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detecting myocardial salvage after primary PTCA: early myocardial contrast echocardiography versus delayed sestamibi perfusion imaging.
    Sciagrà R; Bolognese L; Rovai D; Sestini S; Santoro GM; Cerisano G; Marini C; Buonamici P; Antoniucci D; Fazzini PF
    J Nucl Med; 1999 Mar; 40(3):363-70. PubMed ID: 10086696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accuracy and feasibility of contrast echocardiography for detection of perfusion defects in routine practice: comparison with wall motion and technetium-99m sestamibi single-photon emission computed tomography. The Nycomed NC100100 Investigators.
    Marwick TH; Brunken R; Meland N; Brochet E; Baer FM; Binder T; Flachskampf F; Kamp O; Nienaber C; Nihoyannopoulos P; Pierard L; Vanoverschelde JL; van der Wouw P; Lindvall K
    J Am Coll Cardiol; 1998 Nov; 32(5):1260-9. PubMed ID: 9809934
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of myocardial perfusion in patients with coronary artery disease. Comparison of myocardial contrast echocardiography and 99mTc MIBI single photon emission computed tomography.
    Olszowska M; Kostkiewicz M; Tracz W; Przewlocki T
    Int J Cardiol; 2003 Jul; 90(1):49-55. PubMed ID: 12821219
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of myocardial contrast echocardiography with NC100100 and (99m)Tc sestamibi SPECT for detection of resting myocardial perfusion abnormalities in patients with previous myocardial infarction.
    Jucquois I; Nihoyannopoulos P; D'Hondt AM; Roelants V; Robert A; Melin JA; Glass D; Vanoverschelde JL
    Heart; 2000 May; 83(5):518-24. PubMed ID: 10768900
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of resting perfusion defects in patients with acute myocardial infarction: comparison of myocardial contrast echocardiography, combined first-pass/delayed contrast-enhanced magnetic resonance imaging and 99mTC-sestamibi SPECT.
    Lombardo A; Rizzello V; Galiuto L; Natale L; Giordano A; Rebuzzi A; Loperfido F; Crea F; Maseri A
    Int J Cardiovasc Imaging; 2006; 22(3-4):417-28. PubMed ID: 16496094
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of resting perfusion defect in patients with acute myocardial infarction: comparison of myocardial contrast echocardiography with contrast-enhanced magnetic resonance imaging.
    Olszowska M; Kostkiewicz M; Podolec P; Rubiś P; Tracz W
    Kardiol Pol; 2009 Aug; 67(8A):1013-8. PubMed ID: 19784906
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The value of the TIMI frame count method in the diagnosis of coronary no-reflow: a comparison with myocardial perfusion SPECT in patients with acute myocardial infarction.
    Sahin M; Basoglu T; Canbaz F; Elcik M; Kosus A
    Nucl Med Commun; 2002 Dec; 23(12):1205-10. PubMed ID: 12464786
    [TBL] [Abstract][Full Text] [Related]  

  • 11. NC100100, a new echo contrast agent for the assessment of myocardial perfusion--safety and comparison with technetium-99m sestamibi single-photon emission computed tomography in a randomized multicenter study.
    Binder T; Assayag P; Baer F; Flachskampf F; Kamp O; Nienaber C; Nihoyannopoulos P; Piérard L; Steg G; Vanoverschelde JL; Van der Wouw P; Meland N; Marelli C; Lindvall K
    Clin Cardiol; 1999 Apr; 22(4):273-82. PubMed ID: 10198737
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnostic accuracy of contrast echocardiography during adenosine stress for detection of abnormal myocardial perfusion: a prospective comparison with technetium-99 m sestamibi single-photon emission computed tomography.
    Abdelmoneim SS; Bernier M; Dhoble A; Moir S; Hagen ME; Ness SA; Pellikka PA; Abdel-Kader SS; Mulvagh SL
    Heart Vessels; 2010 Mar; 25(2):121-30. PubMed ID: 20339973
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of infarcted myocardium with real time myocardial contrast echocardiography: comparison with technetium-99m sestamibi single photon emission computed tomography.
    Tousek P; Orban M; Martinoff S; Firschke C
    Heart; 2005 Dec; 91(12):1568-72. PubMed ID: 15774606
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Predictive factors of myocardial reperfusion in patients with anterior wall acute myocardial infarction.
    Olszowska M; Tracz W; Kostkiewicz M; Podolec P
    Cardiol J; 2008; 15(1):57-62. PubMed ID: 18651386
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Early evaluation of coronary microcirculation by echocardiography with contrast medium in patients with acute myocardial infarction treated with primary percutaneous transluminal coronary angioplasty.
    Guiducci V; Fioroni S; Giacometti P; Manari A; Gaddi O
    Minerva Cardioangiol; 2005 Jun; 53(3):157-64. PubMed ID: 16003250
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fractional flow reserve of infarct-related arteries identifies reversible defects on noninvasive myocardial perfusion imaging early after myocardial infarction.
    Samady H; Lepper W; Powers ER; Wei K; Ragosta M; Bishop GG; Sarembock IJ; Gimple L; Watson DD; Beller GA; Barringhaus KG
    J Am Coll Cardiol; 2006 Jun; 47(11):2187-93. PubMed ID: 16750683
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of 99mTc-sestamibi gated SPECT to assess the influence of anterograde flow before primary coronary angioplasty on tissue salvage and functional recovery in acute myocardial infarction.
    Leoncini M; Bellandi F; Sciagrà R; Maioli M; Toso A; Sestini S; Coppola A; Mennuti A; Dabizzi RP; Pupi A
    Eur J Nucl Med Mol Imaging; 2004 Oct; 31(10):1378-85. PubMed ID: 15221297
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sestamibi single photon emission computed tomography immediately after primary percutaneous coronary intervention identifies patients at risk for large infarcts.
    Kaltoft A; Bøttcher M; Sand NP; Rehling M; Andersen NT; Zijlstra F; Nielsen TT
    Am Heart J; 2006 May; 151(5):1108-14. PubMed ID: 16644346
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of sulfur hexafluoride microbubble (SonoVue)-enhanced myocardial contrast echocardiography with gated single-photon emission computed tomography for detection of significant coronary artery disease: a large European multicenter study.
    Senior R; Moreo A; Gaibazzi N; Agati L; Tiemann K; Shivalkar B; von Bardeleben S; Galiuto L; Lardoux H; Trocino G; Carrió I; Le Guludec D; Sambuceti G; Becher H; Colonna P; Ten Cate F; Bramucci E; Cohen A; Bezante G; Aggeli C; Kasprzak JD
    J Am Coll Cardiol; 2013 Oct; 62(15):1353-61. PubMed ID: 23770168
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of myocardial blood flow velocity reserve with myocardial contrast echocardiography in patients with suspected coronary artery disease: comparison with quantitative gated Technetium 99m sestamibi single photon emission computed tomography.
    Dawson D; Rinkevich D; Belcik T; Jayaweera AR; Rafter P; Kaul S; Wei K
    J Am Soc Echocardiogr; 2003 Nov; 16(11):1171-7. PubMed ID: 14608289
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.