BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 1502115)

  • 1. Use of a bonding agent to reduce sealant sensitivity to moisture contamination: an in vitro study.
    Hitt JC; Feigal RJ
    Pediatr Dent; 1992; 14(1):41-6. PubMed ID: 1502115
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of one-bottle adhesive as an intermediate bonding layer to reduce sealant microleakage on saliva-contaminated enamel.
    Hebling J; Feigal RJ
    Am J Dent; 2000 Aug; 13(4):187-91. PubMed ID: 11763928
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro shear bond strength of adhesive to normal and fluoridated enamel under various contaminated conditions.
    Benderli Y; Gökçe K; Büyükgökçesu S
    Quintessence Int; 1999 Aug; 30(8):570-5. PubMed ID: 10635272
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Shear bond strength of a sealant to contaminated-enamel surface: influence of erbium : yttrium-aluminum-garnet laser pretreatment.
    Lepri TP; Souza-Gabriel AE; Atoui JA; Palma-Dibb RG; Pécora JD; Milori Corona SA
    J Esthet Restor Dent; 2008; 20(6):386-92; discussion 393-4. PubMed ID: 19120785
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of blood and saliva contamination on bond strength of brackets bonded with a protective liquid polish and a light-cured adhesive.
    Sayinsu K; Isik F; Sezen S; Aydemir B
    Am J Orthod Dentofacial Orthop; 2007 Mar; 131(3):391-4. PubMed ID: 17346596
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of dentin primer on shear bond strength of composite resin to moist and dry enamel.
    Jain P; Stewart GP
    Oper Dent; 2000; 25(1):51-8. PubMed ID: 11203791
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Shear bond strength of pit-and-fissure sealants to saliva-contaminated and noncontaminated enamel.
    Barroso JM; Torres CP; Lessa FC; Pécora JD; Palma-Dibb RG; Borsatto MC
    J Dent Child (Chic); 2005; 72(3):95-9. PubMed ID: 16568912
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of water, saliva and blood contamination on bonding of metal brackets with a 4-META/MMA/TBB resin to etched enamel.
    Itoh T; Fukushima T; Inoue Y; Arita S; Miyazaki K
    Am J Dent; 1999 Dec; 12(6):299-304. PubMed ID: 10850251
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Resin bond strength and micromorphology of human teeth prepared with an Erbium:YAG laser.
    Trajtenberg CP; Pereira PN; Powers JM
    Am J Dent; 2004 Oct; 17(5):331-6. PubMed ID: 15575443
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reducing microleakage of sealants under salivary contamination: digital-image analysis evaluation.
    Borem LM; Feigal RJ
    Quintessence Int; 1994 Apr; 25(4):283-9. PubMed ID: 8058902
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of individual or simultaneous curing on sealant bond strength.
    Torres CP; Balbo P; Gomes-Silva JM; Ramos RP; Palma-Dibb RG; Borsatto MC
    J Dent Child (Chic); 2005; 72(1):31-5. PubMed ID: 16119073
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Microtensile bond strengths and scanning electron microscopic evaluation of self-adhesive and self-etch resin cements to intact and etched enamel.
    Duarte S; Botta AC; Meire M; Sadan A
    J Prosthet Dent; 2008 Sep; 100(3):203-10. PubMed ID: 18762032
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of bonding agents on the microleakage and bond strength of sealant in primary teeth.
    Tulunoğlu O; Bodur H; Uçtaşli M; Alaçam A
    J Oral Rehabil; 1999 May; 26(5):436-41. PubMed ID: 10373092
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Shear bond strength of some sealants under saliva contamination.
    Rirattanapong P; Vongsavan K; Surarit R
    Southeast Asian J Trop Med Public Health; 2011 Mar; 42(2):463-7. PubMed ID: 21710871
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bond strength of brackets cemented with light-cured glass-ionomer cements to contaminated enamel.
    Itoh T; Fukushima T; Inoue Y; Matsuo N; Matsumoto M
    Am J Dent; 2000 Aug; 13(4):181-6. PubMed ID: 11763927
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microleakage and bond strength of sealant to primary enamel comparing air abrasion and acid etch techniques.
    Knobloch LA; Meyer T; Kerby RE; Johnston W
    Pediatr Dent; 2005; 27(6):463-9. PubMed ID: 16532886
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The influence of blood contamination on bond strengths between dentin and an adhesive resin cement.
    Kaneshima T; Yatani H; Kasai T; Watanabe EK; Yamashita A
    Oper Dent; 2000; 25(3):195-201. PubMed ID: 11203816
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro bracket bond strength to acid-etched or air-abraded enamel.
    Mulcahey K; Caputo AA; Duperon DF
    Pediatr Dent; 1999; 21(4):281-4. PubMed ID: 10436484
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Shear bond strength of stainless steel orthodontic brackets with a moisture-insensitive primer.
    Grandhi RK; Combe EC; Speidel TM
    Am J Orthod Dentofacial Orthop; 2001 Mar; 119(3):251-5. PubMed ID: 11244419
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Saliva contamination of dentin bonding agents.
    Johnson ME; Burgess JO; Hermesch CB; Buikema DJ
    Oper Dent; 1994; 19(6):205-10. PubMed ID: 9028238
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.