80 related articles for article (PubMed ID: 15022478)
1. [Comparison between hemolysis percentage measurement and hemiglobincyanide measurement for standardizing the evaluation of hemolytic properties of biomaterials].
Zhang L; Zhu W; Tan Y; Qu S; Zhang X
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2004 Feb; 21(1):111-4, 137. PubMed ID: 15022478
[TBL] [Abstract][Full Text] [Related]
2. Method for analysis of nanoparticle hemolytic properties in vitro.
Neun BW; Dobrovolskaia MA
Methods Mol Biol; 2011; 697():215-24. PubMed ID: 21116971
[TBL] [Abstract][Full Text] [Related]
3. [The determination of free hemoglobin in blood plasma using the hemiglobincyanide method].
Savel'ev ON; Sukhorukov VP; Kiseleva AV; Koroleva GA
Lab Delo; 1990; (10):45-7. PubMed ID: 1704458
[TBL] [Abstract][Full Text] [Related]
4. Updated Method for In Vitro Analysis of Nanoparticle Hemolytic Properties.
Neun BW; Ilinskaya AN; Dobrovolskaia MA
Methods Mol Biol; 2018; 1682():91-102. PubMed ID: 29039096
[TBL] [Abstract][Full Text] [Related]
5. Spectrophotometry of hemoglobin: a comparison of dog and man.
Zijlstra WG; Buursma A
Comp Biochem Physiol B; 1987; 88(1):251-5. PubMed ID: 3119280
[TBL] [Abstract][Full Text] [Related]
6. An analysis of the bias in red blood cell hemolysis measurement using several analytical approaches.
Acker JP; M Croteau I; Yi QL
Clin Chim Acta; 2012 Nov; 413(21-22):1746-52. PubMed ID: 22750731
[TBL] [Abstract][Full Text] [Related]
7. [Influence of different contact ways and extracting conditions on the hemolytic effect of biomaterials].
Sun J; Gu G; Qian Y
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Mar; 20(1):8-10. PubMed ID: 12744150
[TBL] [Abstract][Full Text] [Related]
8. [Kinetic spectrophotometric study on hemolytic process of polysorbate 80].
Zhang SF; Yan D; Tang HY; Luo Y; Zhang P; Yang M; Wang YS; Xiao XH
Yao Xue Xue Bao; 2010 Apr; 45(4):535-8. PubMed ID: 21355224
[TBL] [Abstract][Full Text] [Related]
9. [Importance of hemolysis on neuron-specific enolase measurement].
Planche V; Brochet C; Bakkouch A; Bernard M
Ann Biol Clin (Paris); 2010; 68(2):239-42. PubMed ID: 20348052
[TBL] [Abstract][Full Text] [Related]
10. In vitro biocompatibility testing of biomaterials and medical devices.
Müller U
Med Device Technol; 2008; 19(2):30, 32-4. PubMed ID: 18605289
[TBL] [Abstract][Full Text] [Related]
11. Purification and characterization of human hemoglobin: effect of the hemolysis conditions.
Andrade CT; Barros LA; Lima MC; Azero EG
Int J Biol Macromol; 2004 Aug; 34(4):233-40. PubMed ID: 15374679
[TBL] [Abstract][Full Text] [Related]
12. [Biocompatibility of graded zirconia-hydroxyapatite composite].
Quan R; Yang D; Miao X
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2006 May; 20(5):569-73. PubMed ID: 16752852
[TBL] [Abstract][Full Text] [Related]
13. Plasma hemoglobin: A method comparison of six assays for hemoglobin and hemolysis index measurement.
Calvaresi EC; La'ulu SL; Snow TM; Allison TR; Genzen JR
Int J Lab Hematol; 2021 Oct; 43(5):1145-1153. PubMed ID: 33449436
[TBL] [Abstract][Full Text] [Related]
14. [Determination of non-erythrocyte hemoglobin of blood plasma (serum) by the hemiglobincyanide method].
Tonkoshkurova OA; Dmitriev AI; Dmitrieva RE
Klin Lab Diagn; 1996; (2):21-2. PubMed ID: 8680762
[TBL] [Abstract][Full Text] [Related]
15. Different substitute biomaterials as potential scaffolds in tissue engineering.
Petrovic L; Schlegel AK; Schultze-Mosgau S; Wiltfang J
Int J Oral Maxillofac Implants; 2006; 21(2):225-31. PubMed ID: 16634492
[TBL] [Abstract][Full Text] [Related]
16. Comparison of photometric cyanmethemoglobin and automated methods for hemoglobin estimation.
Azim W; Parveen S; Parveen S
J Ayub Med Coll Abbottabad; 2002; 14(3):22-3. PubMed ID: 12476859
[TBL] [Abstract][Full Text] [Related]
17. [Quality problems in quantitative determination of hemoglobin in blood].
Pupkova VI; Zhdanova VV; Stepanova EG; Leonova TIa; Palamarchuk MB
Klin Lab Diagn; 2002 Dec; (12):36-9. PubMed ID: 12587554
[TBL] [Abstract][Full Text] [Related]
18. [Industrial output of a hemiglobincyanide reference standard].
Babushkina ZN; Utiamyshev RI
Lab Delo; 1979; (3):147-50. PubMed ID: 85761
[No Abstract] [Full Text] [Related]
19. [Spectrophotometric evaluation of hemolysis tests].
Unger G; Ellinger C; Haberer K
Z Exp Chir Transplant Kunstliche Organe; 1984; 17(6):337-43. PubMed ID: 6516504
[TBL] [Abstract][Full Text] [Related]
20. Hemoglobinometry: A comparison between the hemiglobincyanide method and the Coulter S counter.
Salvati AM; Samoggia P; Taggi F; Tentori L
Clin Chim Acta; 1977 May; 77(1):13-20. PubMed ID: 872420
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]