These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 15025814)

  • 21. Evaluation of hemoglobin interference in capillary heel-stick samples collected for determination of neonatal bilirubin.
    Algeciras-Schimnich A; Cook WJ; Milz TC; Saenger AK; Karon BS
    Clin Biochem; 2007 Nov; 40(16-17):1311-6. PubMed ID: 17825810
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Interference in the creatine kinase assay: the "wave" phenomenon].
    Cohen S
    Ann Biol Clin (Paris); 2003; 61(3):328-31. PubMed ID: 12805011
    [No Abstract]   [Full Text] [Related]  

  • 23. [Precision and accuracy of several types of micro pipettes for serum collection].
    Ichida T; Yashiki T
    Rinsho Byori; 1970 May; 18(5):374-8. PubMed ID: 5465513
    [No Abstract]   [Full Text] [Related]  

  • 24. Drug assay interference caused by plasticizer in Vacutainers.
    Shah VP; Knapp G; Skelly JP; Cabana BE
    Am J Hosp Pharm; 1982 Sep; 39(9):1454. PubMed ID: 7137177
    [No Abstract]   [Full Text] [Related]  

  • 25. Effect of serum separator blood collection tubes on drug concentrations.
    Quattrocchi F; Karnes HT; Robinson JD; Hendeles L
    Ther Drug Monit; 1983; 5(3):359-62. PubMed ID: 6356497
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Methaemoglobin does not interfere with the analysis of glucose in Terumo Venosafe Glycaemia™ tubes.
    Jones I; Böttiger AK
    Scand J Clin Lab Invest; 2013 Mar; 73(2):189-91. PubMed ID: 23216260
    [No Abstract]   [Full Text] [Related]  

  • 27. [CRP can never be "35". The measurement unit is part of the measurement results--and should be standardized].
    Nordin G
    Lakartidningen; 2010 Aug 11-24; 107(32-33):1850-2. PubMed ID: 20873333
    [No Abstract]   [Full Text] [Related]  

  • 28. Evaluation of serum separator tubes as a mail transport device in primary health care.
    Sandberg S; Christensen NG; Horgen E; Jacobsen H; Johansen K
    Scand J Prim Health Care; 1988 Nov; 6(4):251-4. PubMed ID: 3231943
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An automated device for aseptically aspirating serum from blood collection tubes.
    Seebaugh WR; Bradley CA; Parl FF
    IEEE Trans Biomed Eng; 1986 Jun; 33(6):610-6. PubMed ID: 3721533
    [No Abstract]   [Full Text] [Related]  

  • 30. Stability of common biochemical analytes in serum gel tubes subjected to various storage temperatures and times pre-centrifugation.
    Tanner M; Kent N; Smith B; Fletcher S; Lewer M
    Ann Clin Biochem; 2008 Jul; 45(Pt 4):375-9. PubMed ID: 18583622
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Pre-analytical factors and measurement uncertainty.
    Kouri T; Siloaho M; Pohjavaara S; Koskinen P; Malminiemi O; Pohja-Nylander P; Puukka R
    Scand J Clin Lab Invest; 2005; 65(6):463-75. PubMed ID: 16179279
    [TBL] [Abstract][Full Text] [Related]  

  • 32. C-reactive protein associated with coronary artery disease in Iranian patients with angiographically defined coronary artery disease.
    Kazemi-Bajestani SM; Ghayour-Mobarhan M; Ebrahimi M; Moohebati M; Esmaeili HA; Ferns GA
    Clin Lab; 2007; 53(1-2):49-56. PubMed ID: 17323825
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Application of microchip assay system for the measurement of C-reactive protein in human saliva.
    Christodoulides N; Mohanty S; Miller CS; Langub MC; Floriano PN; Dharshan P; Ali MF; Bernard B; Romanovicz D; Anslyn E; Fox PC; McDevitt JT
    Lab Chip; 2005 Mar; 5(3):261-9. PubMed ID: 15726202
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [From sample collection to testing. A. A cover effect of a separating agent in a separator-containing vacuum blood-collecting tube].
    Obara T; Chihara J
    Rinsho Byori; 1996 Nov; Suppl 103():8-20. PubMed ID: 9190427
    [No Abstract]   [Full Text] [Related]  

  • 35. SPR-based immunosensor for the CRP detection--a new method to detect a well known protein.
    Meyer MH; Hartmann M; Keusgen M
    Biosens Bioelectron; 2006 Apr; 21(10):1987-90. PubMed ID: 16246542
    [TBL] [Abstract][Full Text] [Related]  

  • 36. C-reactive protein in patients with gallbladder and biliary tract diseases.
    Vaishnavi C; Singh S; Kochhar R; Singh G; Singh K
    Trop Gastroenterol; 2004; 25(2):73-5. PubMed ID: 15471320
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Storage of plasma in primary plasma separator tubes.
    Madira WM; Wilcox AH; Barron JL
    Ann Clin Biochem; 1993 Mar; 30 ( Pt 2)():213-4. PubMed ID: 8466160
    [No Abstract]   [Full Text] [Related]  

  • 38. Nonenzymatic extraction of DNA from blood collected into serum separator tubes.
    Siafakas N; Burnett L; Bennetts B; Proos A
    Clin Chem; 1995 Jul; 41(7):1045-6. PubMed ID: 7600688
    [No Abstract]   [Full Text] [Related]  

  • 39. Fluorescent nanoparticles as labels for immunometric assay of C-reactive protein using two-photon excitation assay technology.
    Koskinen JO; Vaarno J; Meltola NJ; Soini JT; Hänninen PE; Luotola J; Waris ME; Soini AE
    Anal Biochem; 2004 May; 328(2):210-8. PubMed ID: 15113699
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Optimal collection tubes for plasma glucose determination: confusion reigns supreme.
    Pasqualetti S; Szőke D; Birindelli S; Dolci A; Panteghini M
    Clin Chem Lab Med; 2016 Oct; 54(10):e281-3. PubMed ID: 27197134
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.