BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

251 related articles for article (PubMed ID: 15027312)

  • 21. Standardisation of platelet counting accuracy in blood banks by reference to an automated immunoplatelet procedure: comparative evaluation of Cell-Dyn CD4000 impedance and optical platelet counts.
    Johannessen B; Haugen T; Scott CS
    Transfus Apher Sci; 2001 Oct; 25(2):93-106. PubMed ID: 11761280
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Methods for counting platelets in severe thrombocytopenia.
    Segal HC; Harrison P
    Curr Hematol Rep; 2006 Mar; 5(1):70-5. PubMed ID: 16537049
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of two platelet count estimation methodologies for peripheral blood smears.
    Malok M; Titchener EH; Bridgers C; Lee BY; Bamberg R
    Clin Lab Sci; 2007; 20(3):154-60. PubMed ID: 17691671
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Comparison between two methods for the measurement reticulated platelet and their clinical significance--flow cytometry (FCM) method and IPF method Using automated hematology analyzer (XE-2000)].
    Hayashi S; Nishiyama M; Suehisa E; Kashiwagi H; Kurata Y; Tomiyama Y
    Rinsho Byori; 2009 Nov; 57(11):1039-44. PubMed ID: 20030171
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Compare the accuracy and precision of Coulter LH780, Mindray BC-6000 Plus, and Sysmex XN-9000 with the international reference flow cytometric method in platelet counting.
    Sun Y; Hu Z; Huang Z; Chen H; Qin S; Jianing Z; Chen S; Qin X; Ye Y; Wang C
    PLoS One; 2019; 14(5):e0217298. PubMed ID: 31125378
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Immunoplatelet counting: a proposed new reference procedure.
    Harrison P; Horton A; Grant D; Briggs C; MacHin S
    Br J Haematol; 2000 Feb; 108(2):228-35. PubMed ID: 10691847
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of platelet turnover by flow cytometry.
    Salvagno GL; Montagnana M; Degan M; Marradi PL; Ricetti MM; Riolfi P; Poli G; Minuz P; Santonastaso CL; Guidi GC
    Platelets; 2006 May; 17(3):170-7. PubMed ID: 16702044
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Reduction of the platelet review rate using the two-dimensional platelet method.
    Chapman DH; Hardin J; Miers M; Moyle S; Kinney MC
    Am J Clin Pathol; 2001 Jun; 115(6):894-8. PubMed ID: 11392887
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Flow cytometric platelet enumeration utilizing monoclonal antibody CD42a.
    Tanaka C; Ishii T; Fujimoto K
    Clin Lab Haematol; 1996 Dec; 18(4):265-9. PubMed ID: 9054700
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of platelet counts in simultaneous venous and capillary blood samples using an automated platelet analyser.
    Tai DY; Chan KW; Chee YC; Mak KH
    Singapore Med J; 1995 Jun; 36(3):263-6. PubMed ID: 8553087
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Assessment of an immature platelet fraction (IPF) in peripheral thrombocytopenia.
    Briggs C; Kunka S; Hart D; Oguni S; Machin SJ
    Br J Haematol; 2004 Jul; 126(1):93-9. PubMed ID: 15198738
    [TBL] [Abstract][Full Text] [Related]  

  • 32. An interlaboratory study of a candidate reference method for platelet counting.
    Harrison P; Ault KA; Chapman S; Charie L; Davis B; Fujimoto K; Houwen B; Kunicka J; Lacombe F; Machin S; Raynor R; van Hove L; van Assendelft OW;
    Am J Clin Pathol; 2001 Mar; 115(3):448-59. PubMed ID: 11242802
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Relationships between platelet counts, platelet volumes and reticulated platelets in patients with ITP: evidence for significant platelet count inaccuracies with conventional instrument methods.
    Diquattro M; Gagliano F; Calabrò GM; Tommasi M; Scott CS; Mancuso G; Palma B; Menozzi I
    Int J Lab Hematol; 2009 Apr; 31(2):199-206. PubMed ID: 18190589
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Platelet counting with the BD Accuri(TM) C6 flow cytometer.
    Masters A; Harrison P
    Platelets; 2014; 25(3):175-80. PubMed ID: 23772865
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Is automated platelet counting still a problem in thrombocytopenic blood?
    Oliveira RA; Takadachi MM; Nonoyama K; Barretto OC
    Sao Paulo Med J; 2003 Jan; 121(1):19-23. PubMed ID: 12751339
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Reticulated platelet determination: methodologies and applications for the evaluation of thrombocytopenic disorders].
    Hayashi S; Oshida M; Kiyoi T; Tadokoro S; Kashiwagi H; Honda S; Tomiyama Y; Kurata Y
    Rinsho Ketsueki; 1999 Mar; 40(3):205-12. PubMed ID: 10222627
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Reticulated platelets as a screening test to identify thrombocytopenia aetiology.
    Monteagudo M; Amengual MJ; Muñoz L; Soler JA; Roig I; Tolosa C
    QJM; 2008 Jul; 101(7):549-55. PubMed ID: 18400777
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Discrepancy between impedance and immunofluorescence platelet counting has implications for clinical decision making in patients with idiopathic thrombocytopenia purpura.
    Bowles KM; Bloxham DM; Perry DJ; Baglin TP
    Br J Haematol; 2006 Aug; 134(3):320-2. PubMed ID: 16848774
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of low platelet counts by optical, impedance, and CD61-immunoplatelet methods: estimation of possible inappropriate platelet transfusion.
    Cid J; Nascimento JD; Vicent A; Aguinaco R; Escoda L; Ugarriza A; Llorente A
    Transfusion; 2010 Apr; 50(4):795-800. PubMed ID: 19951312
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of a CD61 MoAb method for enumeration of platelets in thrombocytopenic patients and its impact on the transfusion decision-making process.
    Arroyo JL; García-Marcos MA; López A; Menéndez P; Tabernero MD; Sánchez-Abarca LI; Avila-Zarza C; San Miguel JF; Orfao A
    Transfusion; 2001 Oct; 41(10):1212-6. PubMed ID: 11606818
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.