These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 15036057)

  • 1. Principal component analysis for reduction of ocular artefacts in event-related potentials of normal and dyslexic children.
    Casarotto S; Bianchi AM; Cerutti S; Chiarenza GA
    Clin Neurophysiol; 2004 Mar; 115(3):609-19. PubMed ID: 15036057
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: a simulation case.
    Romero S; Mañanas MA; Barbanoj MJ
    Comput Biol Med; 2008 Mar; 38(3):348-60. PubMed ID: 18222418
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Automatic removal of high-amplitude artefacts from single-channel electroencephalograms.
    Teixeira AR; Tomé AM; Lang EW; Gruber P; Martins da Silva A
    Comput Methods Programs Biomed; 2006 Aug; 83(2):125-38. PubMed ID: 16876903
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Auditory language comprehension in children with developmental dyslexia: evidence from event-related brain potentials.
    Sabisch B; Hahne A; Glass E; von Suchodoletz W; Friederici AD
    J Cogn Neurosci; 2006 Oct; 18(10):1676-95. PubMed ID: 17014373
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis.
    Mantini D; Perrucci MG; Cugini S; Ferretti A; Romani GL; Del Gratta C
    Neuroimage; 2007 Jan; 34(2):598-607. PubMed ID: 17112747
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Recovering dipole sources from scalp-recorded event-related-potentials using component analysis: principal component analysis and independent component analysis.
    Richards JE
    Int J Psychophysiol; 2004 Nov; 54(3):201-20. PubMed ID: 15331212
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Single-trial evoked potentials study by combining wavelet denoising and principal component analysis methods.
    Zou L; Zhang Y; Yang LT; Zhou R
    J Clin Neurophysiol; 2010 Feb; 27(1):17-24. PubMed ID: 20087208
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-throughput ocular artifact reduction in multichannel electroencephalography (EEG) using component subspace projection.
    Ma J; Bayram S; Tao P; Svetnik V
    J Neurosci Methods; 2011 Mar; 196(1):131-40. PubMed ID: 21236300
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Orthographic and phonological processing in Chinese dyslexic children: an ERP study on sentence reading.
    Meng X; Tian X; Jian J; Zhou X
    Brain Res; 2007 Nov; 1179():119-30. PubMed ID: 17904537
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficiency of visual information processing in children at-risk for dyslexia: habituation of single-trial ERPs.
    Regtvoort AG; van Leeuwen TH; Stoel RD; van der Leij A
    Brain Lang; 2006 Sep; 98(3):319-31. PubMed ID: 16870246
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spatiotemporal dynamics of single-letter reading: a combined ERP-FMRI study.
    Casarotto S; Bianchi AM; Ricciardi E; Gentili C; Vanello N; Guazzelli M; Pietrini P; Chiarenza GA; Cerutti S
    Arch Ital Biol; 2008 Jun; 146(2):83-105. PubMed ID: 18822797
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A model-based objective evaluation of eye movement correction in EEG recordings.
    Kierkels JJ; van Boxtel GJ; Vogten LL
    IEEE Trans Biomed Eng; 2006 Feb; 53(2):246-53. PubMed ID: 16485753
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automatic correction of artifact from single-trial event-related potentials by blind source separation using second order statistics only.
    Ting KH; Fung PC; Chang CQ; Chan FH
    Med Eng Phys; 2006 Oct; 28(8):780-94. PubMed ID: 16406675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous measurement of binocular EOG and bilateral EEG activation patterns in dyslexic children.
    Kris C
    Electroencephalogr Clin Neurophysiol; 1970 Oct; 29(4):413. PubMed ID: 4097229
    [No Abstract]   [Full Text] [Related]  

  • 15. Automatic correction of ocular artifacts in the EEG: a comparison of regression-based and component-based methods.
    Wallstrom GL; Kass RE; Miller A; Cohn JF; Fox NA
    Int J Psychophysiol; 2004 Jul; 53(2):105-19. PubMed ID: 15210288
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Decomposing ERP time-frequency energy using PCA.
    Bernat EM; Williams WJ; Gehring WJ
    Clin Neurophysiol; 2005 Jun; 116(6):1314-34. PubMed ID: 15978494
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Removal of BCG artefact from concurrent fMRI-EEG recordings based on EMD and PCA.
    Javed E; Faye I; Malik AS; Abdullah JM
    J Neurosci Methods; 2017 Nov; 291():150-165. PubMed ID: 28842191
    [TBL] [Abstract][Full Text] [Related]  

  • 18. N1 and P2 components of auditory event-related potentials in children with and without reading disabilities.
    Hämäläinen JA; Leppänen PH; Guttorm TK; Lyytinen H
    Clin Neurophysiol; 2007 Oct; 118(10):2263-75. PubMed ID: 17714985
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Picture perception in Chinese dyslexic children: an eye-movement study.
    Li XH; Jing J; Zou XB; Huang X; Jin Y; Wang QX; Chen XB; Yang BR; Yang SY
    Chin Med J (Engl); 2009 Feb; 122(3):267-71. PubMed ID: 19236802
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A fully automated correction method of EOG artifacts in EEG recordings.
    Schlögl A; Keinrath C; Zimmermann D; Scherer R; Leeb R; Pfurtscheller G
    Clin Neurophysiol; 2007 Jan; 118(1):98-104. PubMed ID: 17088100
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.