181 related articles for article (PubMed ID: 15036180)
1. Minimal haemodynamic system model including ventricular interaction and valve dynamics.
Smith BW; Chase JG; Nokes RI; Shaw GM; Wake G
Med Eng Phys; 2004 Mar; 26(2):131-9. PubMed ID: 15036180
[TBL] [Abstract][Full Text] [Related]
2. Effects of atrial contraction, atrioventricular interaction and heart valve dynamics on human cardiovascular system response.
Korakianitis T; Shi Y
Med Eng Phys; 2006 Oct; 28(8):762-79. PubMed ID: 16376600
[TBL] [Abstract][Full Text] [Related]
3. A concentrated parameter model for the human cardiovascular system including heart valve dynamics and atrioventricular interaction.
Korakianitis T; Shi Y
Med Eng Phys; 2006 Sep; 28(7):613-28. PubMed ID: 16293439
[TBL] [Abstract][Full Text] [Related]
4. Simulating transient ventricular interaction using a minimal cardiovascular system model.
Smith BW; Chase JG; Shaw GM; Nokes RI
Physiol Meas; 2006 Feb; 27(2):165-79. PubMed ID: 16400203
[TBL] [Abstract][Full Text] [Related]
5. Simulation of cardiovascular system diseases by including the autonomic nervous system into a minimal model.
Smith BW; Andreassen S; Shaw GM; Jensen PL; Rees SE; Chase JG
Comput Methods Programs Biomed; 2007 May; 86(2):153-60. PubMed ID: 17350711
[TBL] [Abstract][Full Text] [Related]
6. Efficient implementation of non-linear valve law and ventricular interaction dynamics in the minimal cardiac model.
Hann CE; Chase JG; Shaw GM
Comput Methods Programs Biomed; 2005 Oct; 80(1):65-74. PubMed ID: 16039750
[TBL] [Abstract][Full Text] [Related]
7. A new computer model of mitral valve hemodynamics during ventricular filling.
Szabó G; Soans D; Graf A; J Beller C; Waite L; Hagl S
Eur J Cardiothorac Surg; 2004 Aug; 26(2):239-47. PubMed ID: 15296878
[TBL] [Abstract][Full Text] [Related]
8. Integral-based identification of patient specific parameters for a minimal cardiac model.
Hann CE; Chase JG; Shaw GM
Comput Methods Programs Biomed; 2006 Feb; 81(2):181-92. PubMed ID: 16413632
[TBL] [Abstract][Full Text] [Related]
9. A multi-scale computational method applied to the quantitative evaluation of the left ventricular function.
Liang F; Taniguchi H; Liu H
Comput Biol Med; 2007 May; 37(5):700-15. PubMed ID: 16914132
[TBL] [Abstract][Full Text] [Related]
10. Numerical simulation of cardiovascular dynamics with healthy and diseased heart valves.
Korakianitis T; Shi Y
J Biomech; 2006; 39(11):1964-82. PubMed ID: 16140309
[TBL] [Abstract][Full Text] [Related]
11. Numerical simulation of cardiovascular dynamics with different types of VAD assistance.
Shi Y; Korakianitis T; Bowles C
J Biomech; 2007; 40(13):2919-33. PubMed ID: 17433816
[TBL] [Abstract][Full Text] [Related]
12. Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data.
Morley D; Litwak K; Ferber P; Spence P; Dowling R; Meyns B; Griffith B; Burkhoff D
J Thorac Cardiovasc Surg; 2007 Jan; 133(1):21-8. PubMed ID: 17198776
[TBL] [Abstract][Full Text] [Related]
13. A closed-loop model of the canine cardiovascular system that includes ventricular interaction.
Olansen JB; Clark JW; Khoury D; Ghorbel F; Bidani A
Comput Biomed Res; 2000 Aug; 33(4):260-95. PubMed ID: 10944405
[TBL] [Abstract][Full Text] [Related]
14. Performance prediction of a percutaneous ventricular assist system using nonlinear circuit analysis techniques.
Yu YC; Simaan MA; Mushi SE; Zorn NV
IEEE Trans Biomed Eng; 2008 Feb; 55(2 Pt 1):419-29. PubMed ID: 18269977
[TBL] [Abstract][Full Text] [Related]
15. Investigation of cardiac and cardio-therapeutical phenomena using a pulsatile circulatory model.
Welp C; Werner J; Böhringer D; Hexamer M
Biomed Tech (Berl); 2004 Nov; 49(11):327-31. PubMed ID: 15624871
[TBL] [Abstract][Full Text] [Related]
16. [Hemodynamics study of cardiovascular system in vitro simulation].
Li H; Qian K
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Aug; 23(4):778-80. PubMed ID: 17002106
[TBL] [Abstract][Full Text] [Related]
17. Valveless pumping in a fluid-filled closed elastic tube-system: one-dimensional theory with experimental validation.
Ottesen JT
J Math Biol; 2003 Apr; 46(4):309-32. PubMed ID: 12673509
[TBL] [Abstract][Full Text] [Related]
18. On the opening mechanism of the aortic valve: some observations from simulations.
Howard IC; Patterson EA; Yoxall A
J Med Eng Technol; 2003; 27(6):259-66. PubMed ID: 14602517
[TBL] [Abstract][Full Text] [Related]
19. Non-linear fluid-coupled computational model of the mitral valve.
Einstein DR; Kunzelman KS; Reinhall PG; Nicosia MA; Cochran RP
J Heart Valve Dis; 2005 May; 14(3):376-85. PubMed ID: 15974533
[TBL] [Abstract][Full Text] [Related]
20. Model-based identification of PEEP titrations during different volemic levels.
Starfinger C; Chase JG; Hann CE; Shaw GM; Lambert P; Smith BW; Sloth E; Larsson A; Andreassen S; Rees S
Comput Methods Programs Biomed; 2008 Aug; 91(2):135-44. PubMed ID: 18466998
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]