284 related articles for article (PubMed ID: 15046758)
1. Polyvinylferrocenium modified Pt electrode for the design of amperometric choline and acetylcholine enzyme electrodes.
Sen S; Gülce A; Gülce H
Biosens Bioelectron; 2004 May; 19(10):1261-8. PubMed ID: 15046758
[TBL] [Abstract][Full Text] [Related]
2. Amperometric glucose biosensor based on gold-deposited polyvinylferrocene film on Pt electrode.
Topçu Sulak M; Gökdoğan O; Gülce A; Gülce H
Biosens Bioelectron; 2006 Mar; 21(9):1719-26. PubMed ID: 16198102
[TBL] [Abstract][Full Text] [Related]
3. Polyvinylferrocenium modified Pt electrode for anaerobic glucose monitoring.
Gülce A; Gülce H
J Biochem Biophys Methods; 2005 Jan; 62(1):81-92. PubMed ID: 15656946
[TBL] [Abstract][Full Text] [Related]
4. An amperometric enzyme electrode for creatine determination prepared by the immobilization of creatinase and sarcosine oxidase in poly(vinylferrocenium).
Erden PE; Pekyardimci S; Kiliç E; Arslan F
Artif Cells Blood Substit Immobil Biotechnol; 2006; 34(2):223-39. PubMed ID: 16537176
[TBL] [Abstract][Full Text] [Related]
5. A new amperometric enzyme electrode for alcohol determination.
Gülce H; Gülce A; Kavanoz M; Coşkun H; Yildiz A
Biosens Bioelectron; 2002 Jun; 17(6-7):517-21. PubMed ID: 11959473
[TBL] [Abstract][Full Text] [Related]
6. Pt based enzyme electrode probes assembled with Prussian Blue and conducting polymer nanostructures.
Curulli A; Valentini F; Orlanduci S; Terranova ML; Palleschi G
Biosens Bioelectron; 2004 Dec; 20(6):1223-32. PubMed ID: 15556371
[TBL] [Abstract][Full Text] [Related]
7. Development of amperometric glucose biosensor through immobilizing enzyme in a Pt nanoparticles/mesoporous carbon matrix.
Yu J; Yu D; Zhao T; Zeng B
Talanta; 2008 Feb; 74(5):1586-91. PubMed ID: 18371821
[TBL] [Abstract][Full Text] [Related]
8. Amperometric biosensors based on deposition of gold and platinum nanoparticles on polyvinylferrocene modified electrode for xanthine detection.
Baş SZ; Gülce H; Yıldız S; Gülce A
Talanta; 2011 Dec; 87():189-96. PubMed ID: 22099667
[TBL] [Abstract][Full Text] [Related]
9. A novel two-enzyme amperometric electrode for lactose determination.
Gülce H; Gülce A; Yildiz A
Anal Sci; 2002 Feb; 18(2):147-50. PubMed ID: 11874116
[TBL] [Abstract][Full Text] [Related]
10. An amperometric biosensor for choline determination prepared from choline oxidase immobilized in polypyrrole-polyvinylsulfonate film.
Özdemir M; Arslan F; Arslan H
Artif Cells Blood Substit Immobil Biotechnol; 2012 Aug; 40(4):280-4. PubMed ID: 22471595
[TBL] [Abstract][Full Text] [Related]
11. Amperometric enzyme electrode for organic peroxides determination prepared from horseradish peroxidase immobilized in poly(vinylferrocenium) film.
Gündoğan-Paul M; Celebi SS; Ozyörük H; Yildiz A
Biosens Bioelectron; 2002 Oct; 17(10):875-81. PubMed ID: 12243906
[TBL] [Abstract][Full Text] [Related]
12. Amperometric phenol biosensor based on horseradish peroxidase entrapped PVF and PPy composite film coated GC electrode.
Topcu Sulak M; Erhan E; Keskinler B
Appl Biochem Biotechnol; 2010 Mar; 160(3):856-67. PubMed ID: 19224403
[TBL] [Abstract][Full Text] [Related]
13. Study on enzyme electrode biosensor of choline.
Feng D; Sun S; Zhu F; Zhu S; Wang N; Ge S
Chin J Biotechnol; 1997; 13(2):123-9. PubMed ID: 9343711
[TBL] [Abstract][Full Text] [Related]
14. Amperometric determination of acetylcholine-A neurotransmitter, by chitosan/gold-coated ferric oxide nanoparticles modified gold electrode.
Chauhan N; Pundir CS
Biosens Bioelectron; 2014 Nov; 61():1-8. PubMed ID: 24836212
[TBL] [Abstract][Full Text] [Related]
15. A performance comparison of choline biosensors: anodic or cathodic detections of H2O2 generated by enzyme immobilized on a conducting polymer.
Rahman MA; Park DS; Shim YB
Biosens Bioelectron; 2004 Jul; 19(12):1565-71. PubMed ID: 15142589
[TBL] [Abstract][Full Text] [Related]
16. An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel/chitosan hybrid composite film.
Tan X; Li M; Cai P; Luo L; Zou X
Anal Biochem; 2005 Feb; 337(1):111-20. PubMed ID: 15649383
[TBL] [Abstract][Full Text] [Related]
17. Characterization of redox polymer based electrode and electrochemical behavior for DNA detection.
Kuralay F; Erdem A; Abaci S; Ozyörük H; Yildiz A
Anal Chim Acta; 2009 Jun; 643(1-2):83-9. PubMed ID: 19446067
[TBL] [Abstract][Full Text] [Related]
18. Amperometric biosensor for hydrogen peroxide based on coimmobilized horseradish peroxidase and methylene green in ormosils matrix with multiwalled carbon nanotubes.
Upadhyay AK; Ting TW; Chen SM
Talanta; 2009 Jun; 79(1):38-45. PubMed ID: 19376341
[TBL] [Abstract][Full Text] [Related]
19. Pt nanoparticle-based highly sensitive platform for the enzyme-free amperometric sensing of H2O2.
Chakraborty S; Raj CR
Biosens Bioelectron; 2009 Jul; 24(11):3264-8. PubMed ID: 19442506
[TBL] [Abstract][Full Text] [Related]
20. Ferrocene branched chitosan for the construction of a reagentless amperometric hydrogen peroxide biosensor.
Garcia A; Peniche-Covas C; Chico B; Simpson BK; Villalonga R
Macromol Biosci; 2007 Apr; 7(4):435-9. PubMed ID: 17429804
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]