These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 15047401)

  • 1. Ultrasonic guided wave parameters for detection of axial cracks in feeder pipes of PHWR nuclear power plants.
    Cheong YM; Lee DH; Jung HK
    Ultrasonics; 2004 Apr; 42(1-9):883-8. PubMed ID: 15047401
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Propagation phenomena of wideband guided waves in a bended pipe.
    Nishino H; Yoshida K; Cho H; Takemoto M
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1139-43. PubMed ID: 16806367
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Circumferential and longitudinal defect detection using T(0,1) mode excited by thickness shear mode piezoelectric elements.
    Liu Z; He C; Wu B; Wang X; Yang S
    Ultrasonics; 2006 Dec; 44 Suppl 1():e1135-8. PubMed ID: 17064749
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Natural beam focusing of non-axisymmetric guided waves in large-diameter pipes.
    Li J; Rose JL
    Ultrasonics; 2006 Jan; 44(1):35-45. PubMed ID: 16182330
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Excitation and scattering of guided waves: relationships between solutions for plates and pipes.
    Velichko A; Wilcox PD
    J Acoust Soc Am; 2009 Jun; 125(6):3623-31. PubMed ID: 19507944
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection and quantification of pipe damage from change in time of flight and phase.
    Amjad U; Yadav SK; Kundu T
    Ultrasonics; 2015 Sep; 62():223-36. PubMed ID: 26096882
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Guided torsional wave generation of a linear in-plane shear piezoelectric array in metallic pipes.
    Zhou W; Yuan FG; Shi T
    Ultrasonics; 2016 Feb; 65():69-77. PubMed ID: 26548525
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The application of synthetic focusing for imaging crack-like defects in pipelines using guided waves.
    Davies J; Cawley P
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Apr; 56(4):759-71. PubMed ID: 19406704
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of mechanical and geometrical properties of a tube with axial and circumferential guided waves.
    Yeh CH; Yang CH
    Ultrasonics; 2011 May; 51(4):472-9. PubMed ID: 21211810
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The reflection of the fundamental torsional mode from cracks and notches in pipes.
    Demma A; Cawley P; Lowe M; Roosenbrand AG
    J Acoust Soc Am; 2003 Aug; 114(2):611-25. PubMed ID: 12942945
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Circumferential SH Wave Piezoelectric Transducer System for Monitoring Corrosion-Like Defect in Large-Diameter Pipes.
    Zhang H; Du Y; Tang J; Kang G; Miao H
    Sensors (Basel); 2020 Jan; 20(2):. PubMed ID: 31947547
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Helical comb magnetostrictive patch transducers for inspecting spiral welded pipes using flexural guided waves.
    Zhang X; Tang Z; Lv F; Pan X
    Ultrasonics; 2017 Feb; 74():1-10. PubMed ID: 27718376
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pipe wall damage detection by electromagnetic acoustic transducer generated guided waves in absence of defect signals.
    Vasiljevic M; Kundu T; Grill W; Twerdowski E
    J Acoust Soc Am; 2008 May; 123(5):2591-7. PubMed ID: 18529178
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The reflection of guided waves from simple dents in pipes.
    Ma S; Wu Z; Wang Y; Liu K
    Ultrasonics; 2015 Mar; 57():190-7. PubMed ID: 25497001
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Edge resonance in semi-infinite thick pipe: numerical predictions and measurements.
    Ratassepp M; Klauson A; Chati F; Léon F; Maze G
    J Acoust Soc Am; 2008 Aug; 124(2):875-85. PubMed ID: 18681580
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wave structure analysis of guided waves in a bar with an arbitrary cross-section.
    Hayashi T; Tamayama C; Murase M
    Ultrasonics; 2006 Jan; 44(1):17-24. PubMed ID: 16125212
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lamb wave tomography of pipe-like structures.
    Leonard KR; Hinders MK
    Ultrasonics; 2005 Jun; 43(7):574-83. PubMed ID: 15950033
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Scattering of the fundamental torsional mode at an axial crack in a pipe.
    Ratassepp M; Fletcher S; Lowe MJ
    J Acoust Soc Am; 2010 Feb; 127(2):730-40. PubMed ID: 20136195
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Superposition model of mode shapes composed of travelling torsional guided waves excited by multiple circular transducer arrays in pipes.
    Niu X; Tee KF; Marques HR
    Ultrasonics; 2021 Sep; 116():106507. PubMed ID: 34216990
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mode-selective excitation and detection of ultrasonic guided waves for delamination detection in laminated aluminum plates.
    Shelke A; Kundu T; Amjad U; Hahn K; Grill W
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Mar; 58(3):567-77. PubMed ID: 21429847
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.