BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 15047412)

  • 1. Estimating localized oscillatory tissue motion for assessment of the underlying mechanical modulus.
    Konofagou EE; Ottensmeyer M; Agabian S; Dawson SL; Hynynen K
    Ultrasonics; 2004 Apr; 42(1-9):951-6. PubMed ID: 15047412
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Localized harmonic motion imaging: theory, simulations and experiments.
    Konofagou EE; Hynynen K
    Ultrasound Med Biol; 2003 Oct; 29(10):1405-13. PubMed ID: 14597337
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Single-element focused ultrasound transducer method for harmonic motion imaging.
    Maleke C; Pernot M; Konofagou EE
    Ultrason Imaging; 2006 Jul; 28(3):144-58. PubMed ID: 17147056
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simulation study of amplitude-modulated (AM) harmonic motion imaging (HMI) for stiffness contrast quantification with experimental validation.
    Maleke C; Luo J; Gamarnik V; Lu XL; Konofagou EE
    Ultrason Imaging; 2010 Jul; 32(3):154-76. PubMed ID: 20718245
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Harmonic motion imaging for focused ultrasound (HMIFU): a fully integrated technique for sonication and monitoring of thermal ablation in tissues.
    Maleke C; Konofagou EE
    Phys Med Biol; 2008 Mar; 53(6):1773-93. PubMed ID: 18367802
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Non-contact, ultrasound-based indentation method for measuring elastic properties of biological tissues using harmonic motion imaging (HMI).
    Vappou J; Hou GY; Marquet F; Shahmirzadi D; Grondin J; Konofagou EE
    Phys Med Biol; 2015 Apr; 60(7):2853-68. PubMed ID: 25776065
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Elasticity mapping of murine abdominal organs in vivo using harmonic motion imaging (HMI).
    Payen T; Palermo CF; Sastra SA; Chen H; Han Y; Olive KP; Konofagou EE
    Phys Med Biol; 2016 Aug; 61(15):5741-54. PubMed ID: 27401609
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A mechanical model to compute elastic modulus of tissues for harmonic motion imaging.
    Shan B; Pelegri AA; Maleke C; Konofagou EE
    J Biomech; 2008 Jul; 41(10):2150-8. PubMed ID: 18571182
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI).
    Han Y; Hou GY; Wang S; Konofagou E
    Phys Med Biol; 2015 Aug; 60(15):5911-24. PubMed ID: 26184846
    [TBL] [Abstract][Full Text] [Related]  

  • 10. In vivo feasibility of real-time monitoring of focused ultrasound surgery (FUS) using harmonic motion imaging (HMI).
    Maleke C; Konofagou EE
    IEEE Trans Biomed Eng; 2010 Jan; 57(1):7-11. PubMed ID: 19643703
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimization of real-time acoustical and mechanical monitoring of high intensity focused ultrasound (HIFU) treatment using harmonic motion imaging for high focused ultrasound (HMIFU).
    Hou GY; Marquet F; Wang S; Konofagou EE
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():6281-4. PubMed ID: 24111176
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Real-time Monitoring of High Intensity Focused Ultrasound (HIFU) Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU).
    Grondin J; Payen T; Wang S; Konofagou EE
    J Vis Exp; 2015 Nov; (105):e53050. PubMed ID: 26556647
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Harmonic motion imaging for abdominal tumor detection and high-intensity focused ultrasound ablation monitoring: an in vivo feasibility study in a transgenic mouse model of pancreatic cancer.
    Chen H; Hou GY; Han Y; Payen T; Palermo CF; Olive KP; Konofagou EE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Sep; 62(9):1662-73. PubMed ID: 26415128
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monitored steady-state excitation and recovery (MSSER) radiation force imaging using viscoelastic models.
    Mauldin FW; Haider MA; Loboa EG; Behler RH; Euliss LE; Pfeiler TW; Gallippi CM
    IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Jul; 55(7):1597-610. PubMed ID: 18986950
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Focused Ultrasound Steering for Harmonic Motion Imaging.
    Han Y; Payen T; Wang S; Konofagou E
    IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Feb; 65(2):292-294. PubMed ID: 29424694
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of novel imaging probe for optical/acoustic radiation imaging (OARI).
    Ejofodomi OA; Zderic V; Zara JM
    Med Phys; 2013 Nov; 40(11):111910. PubMed ID: 24320443
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimization of the Tracking Beam Sequence in Harmonic Motion Imaging.
    Liu Y; Saharkhiz N; Hossain MM; Konofagou EE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2024 Jan; 71(1):102-116. PubMed ID: 37917522
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Feasibility of Harmonic Motion Imaging Using a Single Transducer: In Vivo Imaging of Breast Cancer in a Mouse Model and Human Subjects.
    Hossain MM; Saharkhiz N; Konofagou EE
    IEEE Trans Med Imaging; 2021 May; 40(5):1390-1404. PubMed ID: 33523806
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An Efficient and Multi-Focal Focused Ultrasound Technique for Harmonic Motion Imaging.
    Saharkhiz N; Kamimura HAS; Konofagou EE
    IEEE Trans Biomed Eng; 2023 Apr; 70(4):1150-1161. PubMed ID: 36191094
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vivo monitoring of focused ultrasound surgery using local harmonic motion.
    Curiel L; Chopra R; Hynynen K
    Ultrasound Med Biol; 2009 Jan; 35(1):65-78. PubMed ID: 18805626
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.