844 related articles for article (PubMed ID: 15052206)
1. The size of metastatic foci and lymph nodes yielding false-negative and false-positive lymph node staging with positron emission tomography in patients with lung cancer.
Nomori H; Watanabe K; Ohtsuka T; Naruke T; Suemasu K; Uno K
J Thorac Cardiovasc Surg; 2004 Apr; 127(4):1087-92. PubMed ID: 15052206
[TBL] [Abstract][Full Text] [Related]
2. Lymph node staging in lung cancer using [18F]FDG-PET.
Halter G; Buck AK; Schirrmeister H; Aksoy E; Liewald F; Glatting G; Neumaier B; Mühling B; Nüssle-Kügele K; Hetzel M; Sunder-Plassmann L; Reske SN
Thorac Cardiovasc Surg; 2004 Apr; 52(2):96-101. PubMed ID: 15103582
[TBL] [Abstract][Full Text] [Related]
3. Endobronchial ultrasound-guided transbronchial needle aspiration of hilar and mediastinal lymph nodes detected on 18F-fluorodeoxyglucose positron emission tomography/computed tomography.
Minami D; Takigawa N; Oda N; Ninomiya T; Kubo T; Ohashi K; Sato A; Hotta K; Tabata M; Kaji M; Tanimoto M; Kiura K
Jpn J Clin Oncol; 2016 Jun; 46(6):529-33. PubMed ID: 27004902
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of integrated positron emission tomography and computed tomography accuracy in detecting lymph node metastasis in patients with adenocarcinoma vs squamous cell carcinoma.
Billè A; Okiror L; Skanjeti A; Errico L; Arena V; Penna D; Ardissone F; Pelosi E
Eur J Cardiothorac Surg; 2013 Mar; 43(3):574-9. PubMed ID: 22689182
[TBL] [Abstract][Full Text] [Related]
5. The role of extended cervical mediastinoscopy in staging of non-small cell lung cancer of the left lung and a comparison with integrated positron emission tomography and computed tomography: does integrated positron emission tomography and computed tomography reduce the need for invasive procedures?
Metin M; Citak N; Sayar A; Pekcolaklar A; Melek H; Kök A; Gurses A
J Thorac Oncol; 2011 Oct; 6(10):1713-9. PubMed ID: 21716145
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of the factors affecting the maximum standardized uptake value of metastatic lymph nodes in different histological types of non-small cell lung cancer on PET-CT.
Wang Y; Ma S; Dong M; Yao Y; Liu K; Zhou J
BMC Pulm Med; 2015 Mar; 15():20. PubMed ID: 25880540
[TBL] [Abstract][Full Text] [Related]
7. Correlation between FDG uptake by PET/CT and the expressions of glucose transporter type 1 and hexokinase II in cervical cancer.
Tong SY; Lee JM; Ki KD; Choi YJ; Seol HJ; Lee SK; Huh CY; Kim GY; Lim SJ
Int J Gynecol Cancer; 2012 May; 22(4):654-8. PubMed ID: 22398711
[TBL] [Abstract][Full Text] [Related]
8. Characteristics of advantages of positron emission tomography over computed tomography for N-staging in lung cancer patients.
Ebihara A; Nomori H; Watanabe K; Ohtsuka T; Naruke T; Uno K; Kuwahira I; Eguchi K
Jpn J Clin Oncol; 2006 Nov; 36(11):694-8. PubMed ID: 17068084
[TBL] [Abstract][Full Text] [Related]
9. Diagnostic accuracy of (18)F-2-deoxy-fluoro-D-glucose positron emission tomography for pN2 lymph nodes in patients with lung cancer.
Ozawa Y; Hara M; Sakurai K; Nakagawa M; Tamaki T; Nishio M; Shibamoto Y
Acta Radiol; 2010 Mar; 51(2):150-5. PubMed ID: 20092375
[TBL] [Abstract][Full Text] [Related]
10. Mediastinoscopy might not be necessary in patients with non-small cell lung cancer with mediastinal lymph nodes having a maximum standardized uptake value of less than 5.3.
Lee BE; Redwine J; Foster C; Abella E; Lown T; Lau D; Follette D
J Thorac Cardiovasc Surg; 2008 Mar; 135(3):615-9. PubMed ID: 18329480
[TBL] [Abstract][Full Text] [Related]
11. Diffusion-weighted magnetic resonance imaging can be used in place of positron emission tomography for N staging of non-small cell lung cancer with fewer false-positive results.
Nomori H; Mori T; Ikeda K; Kawanaka K; Shiraishi S; Katahira K; Yamashita Y
J Thorac Cardiovasc Surg; 2008 Apr; 135(4):816-22. PubMed ID: 18374761
[TBL] [Abstract][Full Text] [Related]
12. [Evaluation of the diagnostic value of (18)F-FDG PET-CT and enhanced CT for staging of lymph node metastasis in non-small cell lung cancer].
Yang WF; Tan GZ; Fu Z; Yu JM
Zhonghua Zhong Liu Za Zhi; 2009 Dec; 31(12):925-8. PubMed ID: 20193335
[TBL] [Abstract][Full Text] [Related]
13. Accuracy of positron emission tomography in mediastinal node assessment in coal workers with lung cancer.
Saydam O; Gokce M; Kilicgun A; Tanriverdi O
Med Oncol; 2012 Jun; 29(2):589-94. PubMed ID: 21380783
[TBL] [Abstract][Full Text] [Related]
14. [18F] 3-deoxy-3'-fluorothymidine positron emission tomography: alternative or diagnostic adjunct to 2-[18f]-fluoro-2-deoxy-D-glucose positron emission tomography in the workup of suspicious central focal lesions?
Halter G; Buck AK; Schirrmeister H; Wurziger I; Liewald F; Glatting G; Neumaier B; Sunder-Plassmann L; Reske SN; Hetzel M
J Thorac Cardiovasc Surg; 2004 Apr; 127(4):1093-9. PubMed ID: 15052207
[TBL] [Abstract][Full Text] [Related]
15. Integrated positron emission tomography and computed tomography in preoperative lymph node staging of non-small cell lung cancer.
Xu N; Wang M; Zhu Z; Zhang Y; Jiao Y; Fang W
Chin Med J (Engl); 2014; 127(4):607-13. PubMed ID: 24534208
[TBL] [Abstract][Full Text] [Related]
16. Endoscopic ultrasound-guided fine needle aspiration of mediastinal lymph node in patients with suspected lung cancer after positron emission tomography and computed tomography scans.
Eloubeidi MA; Cerfolio RJ; Chen VK; Desmond R; Syed S; Ojha B
Ann Thorac Surg; 2005 Jan; 79(1):263-8. PubMed ID: 15620955
[TBL] [Abstract][Full Text] [Related]
17. Mediastinal lymph node staging of non-small-cell lung cancer: a prospective comparison of computed tomography and positron emission tomography.
Scott WJ; Gobar LS; Terry JD; Dewan NA; Sunderland JJ
J Thorac Cardiovasc Surg; 1996 Mar; 111(3):642-8. PubMed ID: 8601980
[TBL] [Abstract][Full Text] [Related]
18. Mediastinal lymph node staging by FDG-PET in patients with non-small cell lung cancer: analysis of false-positive FDG-PET findings.
Konishi J; Yamazaki K; Tsukamoto E; Tamaki N; Onodera Y; Otake T; Morikawa T; Kinoshita I; Dosaka-Akita H; Nishimura M
Respiration; 2003; 70(5):500-6. PubMed ID: 14665776
[TBL] [Abstract][Full Text] [Related]
19. Advantages of diffusion-weighted imaging over positron emission tomography-computed tomography in assessment of hilar and mediastinal lymph node in lung cancer.
Usuda K; Sagawa M; Motono N; Ueno M; Tanaka M; Machida Y; Matoba M; Kuginuki Y; Taniguchi M; Ueda Y; Sakuma T
Ann Surg Oncol; 2013 May; 20(5):1676-83. PubMed ID: 23242821
[TBL] [Abstract][Full Text] [Related]
20. External ultrasonography of the neck does not add diagnostic value to integrated positron emission tomography-computed tomography (PET-CT) scanning in the diagnosis of cervical lymph node metastases in patients with esophageal carcinoma.
Blom RL; Vliegen RF; Schreurs WM; Belgers HJ; Stohr I; Oostenbrug LE; Sosef MN
Dis Esophagus; 2012 Aug; 25(6):555-9. PubMed ID: 22150869
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]