These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 15061361)

  • 21. Performance of a new blood glucose monitoring system in the hands of intended users.
    Bailey TS; Wallace JF; Parkes JL; Pardo S; Yu J; Schachner HC; Simmons DA; Chu A
    Diabetes Technol Ther; 2012 Sep; 14(9):783-9. PubMed ID: 22746838
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Quantitative assessment of the effect of cholesterol on blood glucose measurement using near infrared spectroscopy and a method for error reduction.
    Jiang J; Zhang K; Qin J; Min X; Zhang L; Zou D; Xu K
    Lasers Surg Med; 2015 Jan; 47(1):88-97. PubMed ID: 25559692
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.
    Freckmann G; Baumstark A; Schmid C; Pleus S; Link M; Haug C
    Diabetes Technol Ther; 2014 Feb; 16(2):113-22. PubMed ID: 24205978
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optical coherence tomography-based continuous noninvasive glucose monitoring in patients with diabetes.
    Gabbay RA; Sivarajah S
    Diabetes Technol Ther; 2008 Jun; 10(3):188-93. PubMed ID: 18473692
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Screening for gestational diabetes mellitus in pregnant females.
    Ardawi MS; Nasrat HA; Jamal HS; Al-Sagaaf HM; Mustafa BE
    Saudi Med J; 2000 Feb; 21(2):155-60. PubMed ID: 11533772
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Frequency of impaired glucose tolerance and diabetes mellitus in subjects with fasting blood glucose below 6.1 mmol/L (110 mg/dL).
    Khan SH; Ijaz A; Bokhari SA; Hanif MS; Azam N
    East Mediterr Health J; 2013 Feb; 19(2):175-80. PubMed ID: 23516829
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Optimization of preanalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitus.
    Stahl M; Jørgensen LG; Hyltoft Petersen P; Brandslund I; de Fine Olivarius N; Borch-Johnsen K
    Scand J Clin Lab Invest; 2001 May; 61(3):169-79. PubMed ID: 11386604
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Allowable limits of analytical error which can guarantee the reliability of reference intervals for interpretation of clinical laboratory data].
    Hosogaya S; Ozaki Y
    Rinsho Byori; 2008 Jul; 56(7):617-21. PubMed ID: 18709995
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Evaluation of the relationship between capillary and venous plasma glucose concentrations obtained by the HemoCue Glucose 201+ system during an oral glucose tolerance test.
    Ignell C; Berntorp K
    Scand J Clin Lab Invest; 2011 Dec; 71(8):670-5. PubMed ID: 21961814
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Do new concepts for deriving permissible limits for analytical imprecision and bias have any advantages over existing consensus?
    Petersen PH; Sandberg S; Fraser CG
    Clin Chem Lab Med; 2011 Apr; 49(4):637-40. PubMed ID: 21345044
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Analytical goals developed from the inherent error of medical tests.
    Ross JW; Fraser MD
    Clin Chem; 1993 Jul; 39(7):1481-93; discussion 1493-4. PubMed ID: 8330410
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Prevalence of impaired fasting glycemia, impaired glucose tolerance, and type 2 diabetes in hemodialyzed patients when applying new diagnostic criteria.
    Elbert A; Schreier L; Galli C; Beresan H; Lopez G; Traversa M; Berg G
    J Ren Nutr; 2006 Oct; 16(4):300-3. PubMed ID: 17046613
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Lens fluorescence in relation to glucose tolerance and genetic predisposition to type 2 diabetes mellitus in a population-based study.
    Koefoed Theil P; Kessel L; Hansen T; Lund-Andersen H; Pedersen O; Larsen M
    Curr Eye Res; 2006 Sep; 31(9):733-8. PubMed ID: 16966146
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Fasting plasma glucose cutoff for diagnosis of diabetes in a Japanese population.
    Doi Y; Kubo M; Yonemoto K; Ninomiya T; Iwase M; Arima H; Hata J; Tanizaki Y; Iida M; Kiyohara Y
    J Clin Endocrinol Metab; 2008 Sep; 93(9):3425-9. PubMed ID: 18559920
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Should quality goals be defined for multicenter laboratory testing? Lessons learned from a pilot survey on a national surveillance program for diabetes.
    Wang L; Mo N; Pang R; Deng Q; Liu Y; Hu Y; Hu C; Wang L
    Int J Qual Health Care; 2016 Apr; 28(2):259-63. PubMed ID: 26796487
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Measurement of glucose and diagnosis of diabetes mellitus].
    Odum L
    Ugeskr Laeger; 1999 Feb; 161(7):928-31. PubMed ID: 10051799
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The influence of analytical bias on diagnostic misclassifications.
    Petersen PH; de Verdier CH; Groth T; Fraser CG; Blaabjerg O; Hørder M
    Clin Chim Acta; 1997 Apr; 260(2):189-206. PubMed ID: 9177913
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Comparison of ADA and WHO diagnostic criteria for diabetes diagnosis and other categories of glucose intolerance ].
    Herdzik E; Safranow K; Ciechanowski K; Byra E; Gołdyn U
    Pol Merkur Lekarski; 2002 Oct; 13(76):316-20. PubMed ID: 12557440
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Proposal for the modification of the conventional model for establishing performance specifications.
    Oosterhuis WP; Sandberg S
    Clin Chem Lab Med; 2015 May; 53(6):925-37. PubMed ID: 25901717
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Criteria for previously undiagnosed diabetes and risk of mortality: 15-year follow-up of the Edinburgh Artery Study cohort.
    Wild SH; Smith FB; Lee AJ; Fowkes FG
    Diabet Med; 2005 Apr; 22(4):490-6. PubMed ID: 15787678
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.