BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

330 related articles for article (PubMed ID: 15065175)

  • 1. Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method.
    Morgan PS; Bowtell RW; McIntyre DJ; Worthington BS
    J Magn Reson Imaging; 2004 Apr; 19(4):499-507. PubMed ID: 15065175
    [TBL] [Abstract][Full Text] [Related]  

  • 2. EPI image reconstruction with correction of distortion and signal losses.
    Liu G; Ogawa S
    J Magn Reson Imaging; 2006 Sep; 24(3):683-9. PubMed ID: 16892198
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Image distortion correction in fMRI: A quantitative evaluation.
    Hutton C; Bork A; Josephs O; Deichmann R; Ashburner J; Turner R
    Neuroimage; 2002 May; 16(1):217-40. PubMed ID: 11969330
    [TBL] [Abstract][Full Text] [Related]  

  • 4. EPI distortion correction from a simultaneously acquired distortion map using TRAIL.
    Priest AN; De Vita E; Thomas DL; Ordidge RJ
    J Magn Reson Imaging; 2006 Apr; 23(4):597-603. PubMed ID: 16514595
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Minimization of Nyquist ghosting for echo-planar imaging at ultra-high fields based on a "negative readout gradient" strategy.
    van der Zwaag W; Marques JP; Lei H; Just N; Kober T; Gruetter R
    J Magn Reson Imaging; 2009 Nov; 30(5):1171-8. PubMed ID: 19856451
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single-shot compensation of image distortions and BOLD contrast optimization using multi-echo EPI for real-time fMRI.
    Weiskopf N; Klose U; Birbaumer N; Mathiak K
    Neuroimage; 2005 Feb; 24(4):1068-79. PubMed ID: 15670684
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An inverse problem approach to the correction of distortion in EPI images.
    Munger P; Crelier GR; Peters TM; Pike GB
    IEEE Trans Med Imaging; 2000 Jul; 19(7):681-9. PubMed ID: 11055783
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Single-shot fast spin-echo diffusion tensor imaging of the brain and spine with head and phased array coils at 1.5 T and 3.0 T.
    Xu D; Henry RG; Mukherjee P; Carvajal L; Miller SP; Barkovich AJ; Vigneron DB
    Magn Reson Imaging; 2004 Jul; 22(6):751-9. PubMed ID: 15234443
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A simple simultaneous geometric and intensity correction method for echo-planar imaging by EPI-based phase modulation.
    Chiou JY; Ahn CB; Muftuler LT; Nalcioglu O
    IEEE Trans Med Imaging; 2003 Feb; 22(2):200-5. PubMed ID: 12715996
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigating the benefits of multi-echo EPI for fMRI at 7 T.
    Poser BA; Norris DG
    Neuroimage; 2009 May; 45(4):1162-72. PubMed ID: 19349231
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simple correction method for k-space trajectory deviations in MRI.
    Duyn JH; Yang Y; Frank JA; van der Veen JW
    J Magn Reson; 1998 May; 132(1):150-3. PubMed ID: 9615415
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Doubling the resolution of echo-planar brain imaging by acquisition of two k-space lines per gradient reversal using TRAIL.
    Priest AN; De Vita E; Ordidge RJ
    NMR Biomed; 2008 Feb; 21(2):79-88. PubMed ID: 17506114
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of geometric distortion correction on motion realignment in fMRI.
    Elliott MA; Gualtieri EE; Hulvershorn J; Ragland JD; Gur R
    Acad Radiol; 2004 Sep; 11(9):1005-10. PubMed ID: 15350581
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Geometric distortion in clinical MRI systems Part II: correction using a 3D phantom.
    Wang D; Strugnell W; Cowin G; Doddrell DM; Slaughter R
    Magn Reson Imaging; 2004 Nov; 22(9):1223-32. PubMed ID: 15607093
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A complete distortion correction for MR images: I. Gradient warp correction.
    Doran SJ; Charles-Edwards L; Reinsberg SA; Leach MO
    Phys Med Biol; 2005 Apr; 50(7):1343-61. PubMed ID: 15798328
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of k-space energy spectrum analysis to susceptibility field mapping and distortion correction in gradient-echo EPI.
    Chen NK; Oshio K; Panych LP
    Neuroimage; 2006 Jun; 31(2):609-22. PubMed ID: 16480898
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Diffusion-weighted imaging in patients with acute brain ischemia at 3 T: current possibilities and future perspectives comparing conventional echoplanar diffusion-weighted imaging and fast spin echo diffusion-weighted imaging sequences using BLADE (PROPELLER).
    Fries P; Runge VM; Kirchin MA; Stemmer A; Naul LG; Wiliams KD; Reith W; Bücker A; Schneider G
    Invest Radiol; 2009 Jun; 44(6):351-9. PubMed ID: 19363447
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new EPI-based dynamic field mapping method: application to retrospective geometrical distortion corrections.
    Lamberton F; Delcroix N; Grenier D; Mazoyer B; Joliot M
    J Magn Reson Imaging; 2007 Sep; 26(3):747-55. PubMed ID: 17729370
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Susceptibility-matched envelope for the correction of EPI artifacts.
    Neufeld A; Assaf Y; Graif M; Hendler T; Navon G
    Magn Reson Imaging; 2005 Nov; 23(9):947-51. PubMed ID: 16310110
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.
    Hussain SM; De Becker J; Hop WC; Dwarkasing S; Wielopolski PA
    J Magn Reson Imaging; 2005 Mar; 21(3):219-29. PubMed ID: 15723376
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.