BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 15068006)

  • 1. A modified equivalent annulus model for the hollow fiber hemodialyzer.
    Liao Z; Klein E; Poh CK; Huang Z; Hardy PA; Morti S; Clark WR; Gao D
    Int J Artif Organs; 2004 Feb; 27(2):110-7. PubMed ID: 15068006
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A numerical and experimental study of mass transfer in the artificial kidney.
    Liao Z; Poh CK; Huang Z; Hardy PA; Clark WR; Gao D
    J Biomech Eng; 2003 Aug; 125(4):472-80. PubMed ID: 12968571
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite-element modeling of time-dependent sodium exchange across the hollow fiber of a hemodialyzer by coupling with a blood pool model.
    Ravagli E; Grandi E; Rovatti P; Severi S
    Int J Artif Organs; 2016 Nov; 39(9):471-478. PubMed ID: 27834449
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of novel manufacturing technology on blood and dialysate flow distribution in a new low flux "alpha Polysulfone" hemodialyzer.
    Gastaldon F; Brendolan A; Crepaldi C; Frisone P; Zamboni S; d'Intini V; Poulin S; Hector R; Granziero A; Martins K; Gellert R; Inguaggiato P; Ronco C
    Int J Artif Organs; 2003 Feb; 26(2):105-12. PubMed ID: 12653343
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of fiber structure on dialysate flow profile and hollow-fiber hemodialyzer reliability: CT perfusion study.
    Kim JC; Kim JH; Kim HC; Kang E; Kim KG; Kim HC; Min BG; Ronco C
    Int J Artif Organs; 2008 Nov; 31(11):944-50. PubMed ID: 19089796
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Blood and dialysate flow distributions in hollow-fiber hemodialyzers analyzed by computerized helical scanning technique.
    Ronco C; Brendolan A; Crepaldi C; Rodighiero M; Scabardi M
    J Am Soc Nephrol; 2002 Jan; 13 Suppl 1():S53-61. PubMed ID: 11792763
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Computational flow modeling in hollow-fiber dialyzers.
    Eloot S; De Wachter D; Van Tricht I; Verdonck P
    Artif Organs; 2002 Jul; 26(7):590-9. PubMed ID: 12081517
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of flow baffles on the dialysate flow distribution of hollow-fiber hemodialyzers: a nonintrusive experimental study using MRI.
    Poh CK; Hardy PA; Liao Z; Huang Z; Clark WR; Gao D
    J Biomech Eng; 2003 Aug; 125(4):481-9. PubMed ID: 12968572
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Flow distribution analysis by helical scanning in polysulfone hemodialyzers: effects of fiber structure and design on flow patterns and solute clearances.
    Ronco C; Levin N; Brendolan A; Nalesso F; Cruz D; Ocampo C; Kuang D; Bonello M; De Cal M; Corradi V; Ricci Z
    Hemodial Int; 2006 Oct; 10(4):380-8. PubMed ID: 17014516
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computational modeling of effects of mechanical shaking on hemodynamics in hollow fibers.
    Kim JC; Garzotto F; Cruz DN; Clementi A; Nalesso F; Kim JH; Kang E; Kim HC; Ronco C
    Int J Artif Organs; 2012 Apr; 35(4):301-7. PubMed ID: 22505197
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensional dialysate flow analysis in a hollow-fiber dialyzer by perfusion computed tomography.
    Kim JC; Kim JH; Kim HC; Kim KG; Lee JC; Kang E; Kim HC; Min BG; Ronco C
    Int J Artif Organs; 2008 Jun; 31(6):553-60. PubMed ID: 18609508
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of dialyzer jacket structure and hollow-fiber dialysis membranes to achieve high dialysis performance.
    Hirano A; Yamamoto K; Matsuda M; Ogawa T; Yakushiji T; Miyasaka T; Sakai K
    Ther Apher Dial; 2011 Feb; 15(1):66-74. PubMed ID: 21272255
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enhancement of solute removal in a hollow-fiber hemodialyzer by mechanical vibration.
    Kim JC; Garzotto F; Cruz DN; Goh CY; Nalesso F; Kim JH; Kang E; Kim HC; Ronco C
    Blood Purif; 2011; 31(4):227-34. PubMed ID: 21242675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional simulation of mass transfer in artificial kidneys.
    Ding W; Li W; Sun S; Zhou X; Hardy PA; Ahmad S; Gao D
    Artif Organs; 2015 Jun; 39(6):E79-89. PubMed ID: 25739806
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new method to evaluate the local clearance at different annular rings inside hemodialyzers.
    Huang Z; Klein E; Li B; Poh C; Liao Z; Clark WR; Gao D
    ASAIO J; 2003; 49(6):692-7. PubMed ID: 14655736
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Precise Quantitative Assessment of the Clinical Performances of Two High-Flux Polysulfone Hemodialyzers in Hemodialysis: Validation of a Blood-Based Simple Kinetic Model Versus Direct Dialysis Quantification.
    Lim PS; Lin Y; Chen M; Xu X; Shi Y; Bowry S; Canaud B
    Artif Organs; 2018 May; 42(5):E55-E66. PubMed ID: 29193165
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dialysate flow distribution in hollow fiber hemodialyzers with different dialysate pathway configurations.
    Ronco C; Brendolan A; Crepaldi C; Rodighiero M; Everard P; Ballestri M; Cappelli G; Spittle M; La Greca G
    Int J Artif Organs; 2000 Sep; 23(9):601-9. PubMed ID: 11059882
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Urea separation in flat-plate microchannel hemodialyzer; experiment and modeling.
    Tuhy AR; Anderson EK; Jovanovic GN
    Biomed Microdevices; 2012 Jun; 14(3):595-602. PubMed ID: 22374475
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemodialyzer membranes and configurations: a historical perspective.
    Clark WR
    Semin Dial; 2000; 13(5):309-11. PubMed ID: 11014692
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The influence of the dialysate flow rate on hollow fiber hemodialyzer performance.
    Allen R; Frost TH; Hoenich NA
    Artif Organs; 1995 Nov; 19(11):1176-80. PubMed ID: 8579530
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.