These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

416 related articles for article (PubMed ID: 15069429)

  • 1. Validation of Orbscan II posterior corneal curvature measurement for intraocular lens power calculation.
    Leyland M
    Eye (Lond); 2004 Apr; 18(4):357-60. PubMed ID: 15069429
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia.
    Qazi MA; Cua IY; Roberts CJ; Pepose JS
    J Cataract Refract Surg; 2007 Jan; 33(1):21-30. PubMed ID: 17189789
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Pitfalls of IOL power prediction after photorefractive keratectomy for high myopia -- case report, practical recommendations and literature review].
    Seitz B; Langenbucher A; Haigis W
    Klin Monbl Augenheilkd; 2002 Dec; 219(12):840-50. PubMed ID: 12548468
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy.
    Seitz B; Langenbucher A; Nguyen NX; Kus MM; Küchle M
    Ophthalmology; 1999 Apr; 106(4):693-702. PubMed ID: 10201589
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Estimation of preoperative corneal power in patients with myopic LASIK based on postoperative corneal data measured from Orbscan II].
    Cai JQ; Zhang JY; Yang SH; Cha Y; Shi MG
    Zhonghua Yan Ke Za Zhi; 2011 Feb; 47(2):151-5. PubMed ID: 21426846
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intraocular lens power calculation after myopic refractive surgery: theoretical comparison of different methods.
    Savini G; Barboni P; Zanini M
    Ophthalmology; 2006 Aug; 113(8):1271-82. PubMed ID: 16769117
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyes.
    Savini G; Barboni P; Carbonelli M; Hoffer KJ
    J Cataract Refract Surg; 2012 May; 38(5):787-92. PubMed ID: 22386277
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Consideration of the posterior corneal curvature for assessment of corneal power after myopic LASIK.
    Langenbucher A; Torres F; Behrens A; Suarez E; Haigis W; Seitz B
    Acta Ophthalmol Scand; 2004 Jun; 82(3 Pt 1):264-9. PubMed ID: 15115446
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Orbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis).
    Gelender H
    Trans Am Ophthalmol Soc; 2006; 104():402-13. PubMed ID: 17471353
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Orbscan II-assisted intraocular lens power calculation after LASIK].
    Cai JQ; Zhang JY; Chen R; Yang SH; Zha Y; Shi MG
    Zhonghua Yi Xue Za Zhi; 2011 Jan; 91(1):33-6. PubMed ID: 21418959
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corneal changes after laser refractive surgery for myopia: comparison of Orbscan II and Pentacam findings.
    Hashemi H; Mehravaran S
    J Cataract Refract Surg; 2007 May; 33(5):841-7. PubMed ID: 17466859
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The AS biometry technique--a novel technique to aid accurate intraocular lens power calculation after corneal laser refractive surgery.
    Sambare C; Naroo S; Shah S; Sharma A
    Cont Lens Anterior Eye; 2006 May; 29(2):81-3. PubMed ID: 16600667
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determining corneal power using Orbscan II videokeratography for IOL calculation after excimer laser surgery for myopia.
    Arce CG; Campos M; Schor P
    J Cataract Refract Surg; 2007 Aug; 33(8):1348-9; author reply 1349-50. PubMed ID: 17662405
    [No Abstract]   [Full Text] [Related]  

  • 14. Intraoperative optical refractive biometry for intraocular lens power estimation without axial length and keratometry measurements.
    Ianchulev T; Salz J; Hoffer K; Albini T; Hsu H; Labree L
    J Cataract Refract Surg; 2005 Aug; 31(8):1530-6. PubMed ID: 16129287
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of intraoperative retinoscopy in corneal power and axial length estimation using a high plus soft contact lens.
    Ahmed I; Toufeeq A
    Ophthalmic Physiol Opt; 2005 Jan; 25(1):52-6. PubMed ID: 15649183
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [An analysis of measurement error in Orbscan topography system].
    Du ZY; Zhang DY; Zheng Q; Chen Y; Guo H; Yin HM
    Zhonghua Yan Ke Za Zhi; 2003 Jan; 39(1):36-40. PubMed ID: 12760812
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Analysis of the dynamic changes of cornea after myopic excimer laser in situ keratomileusis using an Orbscan II topography system].
    Wu XY; Liu SZ; Hu SF; Li CL
    Zhonghua Yan Ke Za Zhi; 2006 Sep; 42(9):777-81. PubMed ID: 17173736
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method.
    Kim M; Eom Y; Lee H; Suh YW; Song JS; Kim HM
    Invest Ophthalmol Vis Sci; 2018 Feb; 59(2):1016-1024. PubMed ID: 29450545
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calculation of intraocular lens power using Orbscan II quantitative area topography after corneal refractive surgery.
    Arce CG; Soriano ES; Weisenthal RW; Hamilton SM; Rocha KM; Alzamora JB; Maidana EJ; Vadrevu VL; Himmel K; Schor P; Campos M
    J Refract Surg; 2009 Dec; 25(12):1061-74. PubMed ID: 20000287
    [TBL] [Abstract][Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 21.