BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 15070202)

  • 1. Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise.
    Beddar AS; Suchowerska N; Law SH
    Phys Med Biol; 2004 Mar; 49(5):783-90. PubMed ID: 15070202
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Plastic scintillation dosimetry: optimization of light collection efficiency.
    Beddar AS; Law S; Suchowerska N; Mackie TR
    Phys Med Biol; 2003 May; 48(9):1141-52. PubMed ID: 12765328
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide.
    Lambert J; Yin Y; McKenzie DR; Law S; Suchowerska N
    Phys Med Biol; 2008 Jun; 53(11):3071-80. PubMed ID: 18490811
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration.
    Beddar AS; Mackie TR; Attix FH
    Phys Med Biol; 1992 Oct; 37(10):1883-900. PubMed ID: 1438554
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge.
    Liu PZ; Suchowerska N; Lambert J; Abolfathi P; McKenzie DR
    Phys Med Biol; 2011 Sep; 56(18):5805-21. PubMed ID: 21846934
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A plastic scintillation dosimeter for high dose rate brachytherapy.
    Lambert J; McKenzie DR; Law S; Elsey J; Suchowerska N
    Phys Med Biol; 2006 Nov; 51(21):5505-16. PubMed ID: 17047266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of Cerenkov radiation generated in plastic optical fibers for therapeutic photon beam dosimetry.
    Jang KW; Yagi T; Pyeon CH; Yoo WJ; Shin SH; Jeong C; Min BJ; Shin D; Misawa T; Lee B
    J Biomed Opt; 2013 Feb; 18(2):27001. PubMed ID: 23377008
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
    Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Air core detectors for Cerenkov-free scintillation dosimetry of brachytherapy β-sources.
    Eichmann M; Thomann B
    Med Phys; 2017 Sep; 44(9):4900-4909. PubMed ID: 28548280
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife.
    Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement accuracy and cerenkov removal for high performance, high spatial resolution scintillation dosimetry.
    Archambault L; Beddar AS; Gingras L; Roy R; Beaulieu L
    Med Phys; 2006 Jan; 33(1):128-35. PubMed ID: 16485419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators.
    Archambault L; Arsenault J; Gingras L; Beddar AS; Roy R; Beaulieu L
    Med Phys; 2005 Jul; 32(7):2271-8. PubMed ID: 16121582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. External beam irradiation angle measurement using a hybrid Cerenkov-scintillation detector.
    Jean E; Lambert-Girard S; Therriault-Proulx F; Beaulieu L
    Phys Med Biol; 2022 May; 67(10):. PubMed ID: 35483351
    [No Abstract]   [Full Text] [Related]  

  • 15. Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams.
    Clift MA; Sutton RA; Webb DV
    Phys Med Biol; 2000 May; 45(5):1165-82. PubMed ID: 10843098
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Water equivalent plastic scintillation detectors in radiation therapy.
    Beddar AS
    Radiat Prot Dosimetry; 2006; 120(1-4):1-6. PubMed ID: 16882685
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of plastic scintillating fibres to surface dosimetry in megavoltage photon and electron beams: considerations for Cerenkov correction.
    Monajemi TT; Ruiz EA
    Phys Med Biol; 2018 Sep; 63(18):185003. PubMed ID: 30101759
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Direct reading measurement of absorbed dose with plastic scintillators--the general concept and applications to ophthalmic plaque dosimetry.
    Flühs D; Heintz M; Indenkämpen F; Wieczorek C
    Med Phys; 1996 Mar; 23(3):427-304. PubMed ID: 8815386
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A hybrid radiation detector for simultaneous spatial and temporal dosimetry.
    Poole C; Trapp JV; Kenny J; Kairn T; Williams K; Taylor M; Franich R; Langton CM
    Australas Phys Eng Sci Med; 2011 Sep; 34(3):327-32. PubMed ID: 21678102
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Characterization of Small Volume Plastic Scintillation Detector].
    Fukui Y; Hamada Y; Noma K; Harada N
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(7):652-658. PubMed ID: 31327776
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.