These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 15070202)

  • 1. Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise.
    Beddar AS; Suchowerska N; Law SH
    Phys Med Biol; 2004 Mar; 49(5):783-90. PubMed ID: 15070202
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Plastic scintillation dosimetry: optimization of light collection efficiency.
    Beddar AS; Law S; Suchowerska N; Mackie TR
    Phys Med Biol; 2003 May; 48(9):1141-52. PubMed ID: 12765328
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide.
    Lambert J; Yin Y; McKenzie DR; Law S; Suchowerska N
    Phys Med Biol; 2008 Jun; 53(11):3071-80. PubMed ID: 18490811
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration.
    Beddar AS; Mackie TR; Attix FH
    Phys Med Biol; 1992 Oct; 37(10):1883-900. PubMed ID: 1438554
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge.
    Liu PZ; Suchowerska N; Lambert J; Abolfathi P; McKenzie DR
    Phys Med Biol; 2011 Sep; 56(18):5805-21. PubMed ID: 21846934
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
    Archambault L; Polf JC; Beaulieu L; Beddar S
    Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A plastic scintillation dosimeter for high dose rate brachytherapy.
    Lambert J; McKenzie DR; Law S; Elsey J; Suchowerska N
    Phys Med Biol; 2006 Nov; 51(21):5505-16. PubMed ID: 17047266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of Cerenkov radiation generated in plastic optical fibers for therapeutic photon beam dosimetry.
    Jang KW; Yagi T; Pyeon CH; Yoo WJ; Shin SH; Jeong C; Min BJ; Shin D; Misawa T; Lee B
    J Biomed Opt; 2013 Feb; 18(2):27001. PubMed ID: 23377008
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
    Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Air core detectors for Cerenkov-free scintillation dosimetry of brachytherapy β-sources.
    Eichmann M; Thomann B
    Med Phys; 2017 Sep; 44(9):4900-4909. PubMed ID: 28548280
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife.
    Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L
    Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement accuracy and cerenkov removal for high performance, high spatial resolution scintillation dosimetry.
    Archambault L; Beddar AS; Gingras L; Roy R; Beaulieu L
    Med Phys; 2006 Jan; 33(1):128-35. PubMed ID: 16485419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators.
    Archambault L; Arsenault J; Gingras L; Beddar AS; Roy R; Beaulieu L
    Med Phys; 2005 Jul; 32(7):2271-8. PubMed ID: 16121582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. External beam irradiation angle measurement using a hybrid Cerenkov-scintillation detector.
    Jean E; Lambert-Girard S; Therriault-Proulx F; Beaulieu L
    Phys Med Biol; 2022 May; 67(10):. PubMed ID: 35483351
    [No Abstract]   [Full Text] [Related]  

  • 15. Dealing with Cerenkov radiation generated in organic scintillator dosimeters by bremsstrahlung beams.
    Clift MA; Sutton RA; Webb DV
    Phys Med Biol; 2000 May; 45(5):1165-82. PubMed ID: 10843098
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Water equivalent plastic scintillation detectors in radiation therapy.
    Beddar AS
    Radiat Prot Dosimetry; 2006; 120(1-4):1-6. PubMed ID: 16882685
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of plastic scintillating fibres to surface dosimetry in megavoltage photon and electron beams: considerations for Cerenkov correction.
    Monajemi TT; Ruiz EA
    Phys Med Biol; 2018 Sep; 63(18):185003. PubMed ID: 30101759
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Direct reading measurement of absorbed dose with plastic scintillators--the general concept and applications to ophthalmic plaque dosimetry.
    Flühs D; Heintz M; Indenkämpen F; Wieczorek C
    Med Phys; 1996 Mar; 23(3):427-304. PubMed ID: 8815386
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A hybrid radiation detector for simultaneous spatial and temporal dosimetry.
    Poole C; Trapp JV; Kenny J; Kairn T; Williams K; Taylor M; Franich R; Langton CM
    Australas Phys Eng Sci Med; 2011 Sep; 34(3):327-32. PubMed ID: 21678102
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Characterization of Small Volume Plastic Scintillation Detector].
    Fukui Y; Hamada Y; Noma K; Harada N
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(7):652-658. PubMed ID: 31327776
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.