BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 15070248)

  • 1. Numerical models for the determination of primary structural barriers for diagnostic x-ray facilities.
    Okunade AA
    Med Phys; 2004 Mar; 31(3):513-20. PubMed ID: 15070248
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of lead equivalence of patient and hardware materials in medical diagnostic x-ray shielding.
    Okunade AA
    Health Phys; 2005 Feb; 88(2 Suppl):S34-43. PubMed ID: 15654244
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of shielding requirements for mammography.
    Okunade AA; Ademoroti OA
    Med Phys; 2004 May; 31(5):1210-8. PubMed ID: 15191311
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of the diagnostic radiological index of protection to protective garments.
    Pasciak AS; Jones AK; Wagner LK
    Med Phys; 2015 Feb; 42(2):653-662. PubMed ID: 28102605
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Primary shielding barriers for diagnostic x-ray facilities: a new model.
    Dixon RL; Simpkin DJ
    Health Phys; 1998 Feb; 74(2):181-9. PubMed ID: 9450588
    [TBL] [Abstract][Full Text] [Related]  

  • 6. On the primary barrier in diagnostic x-ray shielding.
    Dixon RL
    Med Phys; 1994 Nov; 21(11):1785-93. PubMed ID: 7891641
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Monte Carlo study of the energy spectra and transmission characteristics of scattered radiation from x-ray computed tomography.
    Platten DJ
    J Radiol Prot; 2014 Jun; 34(2):445-56. PubMed ID: 24894101
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Broad beam attenuation of kilovoltage photon beams: effect of ion chambers.
    Das IJ
    Br J Radiol; 1998 Jan; 71(841):68-73. PubMed ID: 9534701
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiation shielding materials and radiation scatter effects for interventional radiology (IR) physicians.
    McCaffrey JP; Tessier F; Shen H
    Med Phys; 2012 Jul; 39(7):4537-46. PubMed ID: 22830785
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Linear accelerator photon beam quality at off-axis points.
    Yu MK; Sloboda RS; Murray B
    Med Phys; 1997 Feb; 24(2):233-9. PubMed ID: 9048363
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Broad beam attenuation measurements in lead in kilovoltage X-ray beams.
    Akber SF; Das IJ; Kehwar TS
    Z Med Phys; 2008; 18(3):197-202. PubMed ID: 18826163
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Albedos for 4-, 10-, and 18-MV bremsstrahlung x-ray beams on concrete, iron, and lead--normally incident.
    Lo YC
    Med Phys; 1992; 19(3):659-66. PubMed ID: 1324391
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Attenuation of X and Gamma Rays in Personal Radiation Shielding Protective Clothing.
    Kozlovska M; Cerny R; Otahal P
    Health Phys; 2015 Nov; 109(3 Suppl 3):S205-11. PubMed ID: 26425983
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of lead attenuation and lead hardening equivalence of materials used in respect of diagnostic X-ray shielding.
    Okunade AA
    Appl Radiat Isot; 2002 Dec; 57(6):819-24. PubMed ID: 12406622
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On the existence of low-energy photons (<150 keV) in the unflattened x-ray beam from an ordinary radiotherapeutic target in a medical linear accelerator.
    Tsechanski A; Krutman Y; Faermann S
    Phys Med Biol; 2005 Dec; 50(23):5629-39. PubMed ID: 16306657
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A model for calculating shielding requirements in diagnostic X-ray facilities.
    Tsalafoutas IA; Yakoumakis E; Sandilos P
    Br J Radiol; 2003 Oct; 76(910):731-7. PubMed ID: 14512334
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Parameterized algorithms for quantitative differentials in spectrally equivalent medical diagnostic x-ray beams.
    Okunade AA
    Med Phys; 2005 Jun; 32(6):1785-95. PubMed ID: 16013736
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computer simulation of broad-beam and narrow-beam attenuation in lead for diagnostic x-ray energies.
    McLean D
    Med Phys; 1993; 20(5):1549-54. PubMed ID: 8289739
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo simulation of x-ray buildup factors of lead and its applications in shielding of diagnostic x-ray facilities.
    Kharrati H; Agrebi A; Karaoui MK
    Med Phys; 2007 Apr; 34(4):1398-404. PubMed ID: 17500471
    [TBL] [Abstract][Full Text] [Related]  

  • 20. On the production of neutrons in laminated barriers for 10 MV medical accelerator rooms.
    Facure A; da Silva AX; da Rosa LA; Cardoso SC; Rezende GF
    Med Phys; 2008 Jul; 35(7):3285-92. PubMed ID: 18697553
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.