  • 1. Long-term effects of different humidification systems on endotracheal tube patency: evaluation by the acoustic reflection method.
    Jaber S; Pigeot J; Fodil R; Maggiore S; Harf A; Isabey D; Brochard L; Louis B
    Anesthesiology; 2004 Apr; 100(4):782-8. PubMed ID: 15087611
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Gradual reduction of endotracheal tube diameter during mechanical ventilation via different humidification devices.
    Villafane MC; Cinnella G; Lofaso F; Isabey D; Harf A; Lemaire F; Brochard L
    Anesthesiology; 1996 Dec; 85(6):1341-9. PubMed ID: 8968181
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of the effects of two humidifier systems on endotracheal tube resistance.
    Morán I; Cabello B; Manero E; Mancebo J
    Intensive Care Med; 2011 Nov; 37(11):1773-9. PubMed ID: 21946924
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation. A prospective randomized study.
    Misset B; Escudier B; Rivara D; Leclercq B; Nitenberg G
    Chest; 1991 Jul; 100(1):160-3. PubMed ID: 2060336
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Changing a hydrophobic heat and moisture exchanger after 48 hours rather than 24 hours: a clinical and microbiological evaluation.
    Boisson C; Viviand X; Arnaud S; Thomachot L; Miliani Y; Martin C
    Intensive Care Med; 1999 Nov; 25(11):1237-43. PubMed ID: 10654207
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week.
    Ricard JD; Le Mière E; Markowicz P; Lasry S; Saumon G; Djedaïni K; Coste F; Dreyfuss D
    Am J Respir Crit Care Med; 2000 Jan; 161(1):104-9. PubMed ID: 10619805
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of heat and moisture exchanger (HME) positioning on inspiratory gas humidification.
    Inui D; Oto J; Nishimura M
    BMC Pulm Med; 2006 Aug; 6():19. PubMed ID: 16895607
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of Humidification Modality on Incidence of Endotracheal Tube Occlusion in COVID-19 Patients.
    Mattson JR; Gada KD; Jawa R; Zhang X; Ahmad S
    J Intensive Care Med; 2024 Apr; ():8850666241246969. PubMed ID: 38634177
    [No Abstract]   [Full Text] [Related]  

  • 9. Ventilator-associated pneumonia using a heated humidifier or a heat and moisture exchanger: a randomized controlled trial [ISRCTN88724583].
    Lorente L; Lecuona M; Jiménez A; Mora ML; Sierra A
    Crit Care; 2006; 10(4):R116. PubMed ID: 16884530
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A randomized clinical trial comparing an extended-use hygroscopic condenser humidifier with heated-water humidification in mechanically ventilated patients.
    Kollef MH; Shapiro SD; Boyd V; Silver P; Von Harz B; Trovillion E; Prentice D
    Chest; 1998 Mar; 113(3):759-67. PubMed ID: 9515854
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The simultaneous use of a heat and moisture exchanger and a heated humidifier causes critical airway occlusion in less than 24 hours.
    Doyle A; Mariyaselvam M; Wijewardena G; English N; Gent E; Young P
    J Crit Care; 2015 Aug; 30(4):863.e1-3. PubMed ID: 25937239
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The clinical and microbiological comparison of the use of heated humidifiers and heat and moisture exchanger filters with Booster in mechanically ventilated patients].
    Nadir Oziş T; Ozcan Kanat D; Oğuzülgen IK; Aydoğdu M; Hizel K; Gürsel G
    Tuberk Toraks; 2009; 57(3):259-67. PubMed ID: 19787464
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Humidification Performance of Passive and Active Humidification Devices Within a Spontaneously Breathing Tracheostomized Cohort.
    Nakanishi N; Oto J; Itagaki T; Nakataki E; Onodera M; Nishimura M
    Respir Care; 2019 Feb; 64(2):130-135. PubMed ID: 30254040
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Randomized clinical trial of extended use of a hydrophobic condenser humidifier: 1 vs. 7 days.
    Thomachot L; Leone M; Razzouk K; Antonini F; Vialet R; Martin C
    Crit Care Med; 2002 Jan; 30(1):232-7. PubMed ID: 11902268
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation.
    Le Bourdellès G; Mier L; Fiquet B; Djedaïni K; Saumon G; Coste F; Dreyfuss D
    Chest; 1996 Nov; 110(5):1294-8. PubMed ID: 8915237
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of three different humidification systems during prolonged mechanical ventilation.
    Luchetti M; Stuani A; Castelli G; Marraro G
    Minerva Anestesiol; 1998 Mar; 64(3):75-81. PubMed ID: 9677791
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min.
    Martin C; Thomachot L; Quinio B; Viviand X; Albanese J
    Chest; 1995 May; 107(5):1411-5. PubMed ID: 7750340
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia.
    Davis K; Evans SL; Campbell RS; Johannigman JA; Luchette FA; Porembka DT; Branson RD
    Crit Care Med; 2000 May; 28(5):1412-8. PubMed ID: 10834688
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of Airway Humidification Strategy in Mechanically Ventilated COVID-19 Patients.
    Lavoie-Bérard CA; Lefebvre JC; Bouchard PA; Simon M; Lellouche F
    Respir Care; 2022 Feb; 67(2):157-166. PubMed ID: 34670857
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Estimation of tracheal pressure and imposed expiratory work of breathing by the endotracheal tube, heat and moisture exchanger, and ventilator during mechanical ventilation.
    Uchiyama A; Yoshida T; Yamanaka H; Fujino Y
    Respir Care; 2013 Jul; 58(7):1157-69. PubMed ID: 23232731
    [TBL] [Abstract][Full Text] [Related]  