  • 41. [Measurement of the humidity of inspired air in ventilated patients with various humidifer systems].
    Christiansen S; Renzing K; Hirche H; Reidemeister JC
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 May; 33(5):300-5. PubMed ID: 9645289
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Comparing two heat and moisture exchangers, one hydrophobic and one hygroscopic, on humidifying efficacy and the rate of nosocomial pneumonia.
    Thomachot L; Viviand X; Arnaud S; Boisson C; Martin CD
    Chest; 1998 Nov; 114(5):1383-9. PubMed ID: 9824019
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Comparative evaluation of three heat and moisture exchangers during short-term postoperative mechanical ventilation.
    Sottiaux T; Mignolet G; Damas P; Lamy M
    Chest; 1993 Jul; 104(1):220-4. PubMed ID: 8325074
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Short-Term Effects of an Active Heat-and-Moisture Exchanger During Invasive Ventilation.
    Schreiber AF; Ceriana P; Ambrosino N; Piran M; Malovini A; Carlucci A
    Respir Care; 2019 Oct; 64(10):1215-1221. PubMed ID: 31270176
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [The effect of a heat and moisture exchanger (HME) on bronchial mucus transport in a closed inhalation anesthesia system].
    Konrad F; Mezödy M; Goertz A; Marx T; Georgieff M
    Anaesthesist; 1996 Sep; 45(9):802-6. PubMed ID: 8967597
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Heated Humidifier versus Heat-and-Moisture Exchanger During Positive Pressure Ventilation With a T-Piece Resuscitator in Rabbits.
    Bernatzky A; Galletti MF; Fuensalida SE; Mariani GL
    Respir Care; 2020 Sep; 65(9):1295-1300. PubMed ID: 32127411
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Evaluation of resistance in 8 different heat-and-moisture exchangers: effects of saturation and flow rate/profile.
    Lucato JJ; Tucci MR; Schettino GP; Adams AB; Fu C; Forti G; de Carvalho CR; de Souza R
    Respir Care; 2005 May; 50(5):636-43. PubMed ID: 15871758
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Short-term effects of humidification devices on respiratory pattern and arterial blood gases during noninvasive ventilation.
    Lellouche F; Pignataro C; Maggiore SM; Girou E; Deye N; Taillé S; Fischler M; Brochard L
    Respir Care; 2012 Nov; 57(11):1879-86. PubMed ID: 22417382
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Measurement of tracheal temperature is not a reliable index of total respiratory heat loss in mechanically ventilated patients.
    Thomachot L; Viviand X; Lagier P; Dejode JM; Albanèse J; Martin C
    Crit Care; 2001; 5(1):24-30. PubMed ID: 11178222
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Double-heater-wire circuits and heat-and-moisture exchangers and the risk of ventilator-associated pneumonia.
    Boots RJ; George N; Faoagali JL; Druery J; Dean K; Heller RF
    Crit Care Med; 2006 Mar; 34(3):687-93. PubMed ID: 16505654
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Effect of the humidification device on the work of breathing during noninvasive ventilation.
    Lellouche F; Maggiore SM; Deye N; Taillé S; Pigeot J; Harf A; Brochard L
    Intensive Care Med; 2002 Nov; 28(11):1582-9. PubMed ID: 12415444
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Heated humidification versus heat and moisture exchangers for ventilated adults and children.
    Kelly M; Gillies D; Todd DA; Lockwood C
    Anesth Analg; 2010 Oct; 111(4):1072. PubMed ID: 20870984
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Humidification and secretion volume in mechanically ventilated patients.
    Solomita M; Palmer LB; Daroowalla F; Liu J; Miller D; LeBlanc DS; Smaldone GC
    Respir Care; 2009 Oct; 54(10):1329-35. PubMed ID: 19796412
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A drop in gas temperature in the external part of the endotracheal tube is problematic during neonatal respiratory support.
    Yamada Y; Kyuno T; Suzuki S; Ito T; Kato I; Togari H
    Pediatr Pulmonol; 2008 Jul; 43(7):666-73. PubMed ID: 18500729
    [TBL] [Abstract][Full Text] [Related]  

  • 55. The combination of a heat and moisture exchanger and a Booster: a clinical and bacteriological evaluation over 96 h.
    Thomachot L; Viviand X; Boyadjiev I; Vialet R; Martin C
    Intensive Care Med; 2002 Feb; 28(2):147-53. PubMed ID: 11907657
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Acoustic method to estimate the longitudinal area profile of endotracheal tubes.
    Van Surell C; Louis B; Lofaso F; Beydon L; Brochard L; Harf A; Fredberg J; Isabey D
    Am J Respir Crit Care Med; 1994 Jan; 149(1):28-33. PubMed ID: 8111593
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilation.
    Roustan JP; Kienlen J; Aubas P; Aubas S; du Cailar J
    Intensive Care Med; 1992; 18(2):97-100. PubMed ID: 1613206
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Airways humidification during mechanical ventilation. Effects on tracheobronchial ciliated cells morphology.
    Cinnella G; Giardina C; Fischetti A; Lecce G; Fiore MG; Serio G; Carravetta G; Dambrosio M; Fiore T
    Minerva Anestesiol; 2005 Oct; 71(10):585-93. PubMed ID: 16163148
    [TBL] [Abstract][Full Text] [Related]  

  • 59. [Electron microscopic analysis of biofilm on tracheal tubes removed from intubated neonates and the relationship between bilofilm and lower respiratory infection].
    Chen BM; Yu JL; Liu GX; Hu LY; Li LQ; Li F; Yang H
    Zhonghua Er Ke Za Zhi; 2007 Sep; 45(9):655-60. PubMed ID: 18021554
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Effectiveness of Humidification with Heat and Moisture Exchanger-booster in Tracheostomized Patients.
    Gonzalez I; Jimenez P; Valdivia J; Esquinas A
    Indian J Crit Care Med; 2017 Aug; 21(8):528-530. PubMed ID: 28904484
    [TBL] [Abstract][Full Text] [Related]  