These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

88 related articles for article (PubMed ID: 15090391)

  • 1. A biomechanical comparison of repair techniques for type II SLAP lesions.
    DiRaimondo CA; Alexander JW; Noble PC; Lowe WR; Lintner DM
    Am J Sports Med; 2004; 32(3):727-33. PubMed ID: 15090391
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A biomechanical comparison of two suture anchor configurations for the repair of type II SLAP lesions subjected to a peel-back mechanism of failure.
    Morgan RJ; Kuremsky MA; Peindl RD; Fleischli JE
    Arthroscopy; 2008 Apr; 24(4):383-8. PubMed ID: 18375268
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical comparison of a knotless suture anchor with standard suture anchor in the repair of type II SLAP tears.
    Sileo MJ; Lee SJ; Kremenic IJ; Orishimo K; Ben-Avi S; McHugh M; Nicholas SJ
    Arthroscopy; 2009 Apr; 25(4):348-54. PubMed ID: 19341920
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A biomechanical comparison of repair techniques in posterior type II superior labral anterior and posterior (SLAP) lesions.
    Yoo JC; Ahn JH; Lee SH; Lim HC; Choi KW; Bae TS; Lee CY
    J Shoulder Elbow Surg; 2008; 17(1):144-9. PubMed ID: 18069010
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical Comparison of Knotless All-Suture Anchors and Knotted All-Suture Anchors in Type II SLAP Lesions: A Cadaveric Study.
    Nolte PC; Midtgaard KS; Ciccotti M; Miles JW; Tanghe KK; Lacheta L; Millett PJ
    Arthroscopy; 2020 Aug; 36(8):2094-2102. PubMed ID: 32591261
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical comparison of 3 suture anchor configurations for repair of type II SLAP lesions.
    Domb BG; Ehteshami JR; Shindle MK; Gulotta L; Zoghi-Moghadam M; MacGillivray JD; Altchek DW
    Arthroscopy; 2007 Feb; 23(2):135-40. PubMed ID: 17276220
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Restoration of labral anatomy and biomechanics after superior labral anterior-posterior repair: comparison of mattress versus simple technique.
    Boddula MR; Adamson GJ; Gupta A; McGarry MH; Lee TQ
    Am J Sports Med; 2012 Apr; 40(4):875-81. PubMed ID: 22302203
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical comparison of knotless anchor repair versus simple suture repair for type II SLAP lesions.
    Uggen C; Wei A; Glousman RE; ElAttrache N; Tibone JE; McGarry MH; Lee TQ
    Arthroscopy; 2009 Oct; 25(10):1085-92. PubMed ID: 19801286
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical evaluation of transosseous rotator cuff repair: do anchors really matter?
    Salata MJ; Sherman SL; Lin EC; Sershon RA; Gupta A; Shewman E; Wang VM; Cole BJ; Romeo AA; Verma NN
    Am J Sports Med; 2013 Feb; 41(2):283-90. PubMed ID: 23239668
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rotator cuff repair with bioabsorbable screws: An in vivo and ex vivo investigation.
    Cummins CA; Strickland S; Appleyard RC; Szomor ZL; Marshall J; Murrell GA
    Arthroscopy; 2003 Mar; 19(3):239-48. PubMed ID: 12627147
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cyclic loading of rotator cuff repairs: an in vitro biomechanical comparison of bioabsorbable tacks with transosseous sutures.
    Bicknell RT; Harwood C; Ferreira L; King GJ; Johnson JA; Faber K; Drosdowech D
    Arthroscopy; 2005 Jul; 21(7):875-80. PubMed ID: 16012502
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of type II SLAP lesion repair techniques on the vascular supply of the long head of the biceps tendon: a cadaveric injection study.
    Phornphutkul C; Tahwang S; Settakorn J
    J Shoulder Elbow Surg; 2021 Apr; 30(4):772-778. PubMed ID: 32711104
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical analysis of a knotless transtendon interimplant mattress repair for partial-thickness articular-sided rotator cuff tears.
    Park MC; Jun BJ; Park CJ; Oh JH; Lee TQ
    Am J Sports Med; 2009 Dec; 37(12):2427-34. PubMed ID: 19940315
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical evaluation of subpectoral biceps tenodesis: dual suture anchor versus interference screw fixation.
    Tashjian RZ; Henninger HB
    J Shoulder Elbow Surg; 2013 Oct; 22(10):1408-12. PubMed ID: 23415819
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical evaluation of open suture anchor fixation versus interference screw for biceps tenodesis.
    Papp DF; Skelley NW; Sutter EG; Ji JH; Wierks CH; Belkoff SM; McFarland EG
    Orthopedics; 2011 Jul; 34(7):e275-8. PubMed ID: 21717988
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A biomechanical comparison of the FasT-Fix meniscal repair suture system and the RapidLoc device in cadaver meniscus.
    Kocabey Y; Chang HC; Brand JC; Nawab A; Nyland J; Caborn DN
    Arthroscopy; 2006 Apr; 22(4):406-13. PubMed ID: 16581453
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors.
    Barber FA; Drew OR
    Arthroscopy; 2012 Sep; 28(9):1197-205. PubMed ID: 22592123
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A biomechanical comparison of EndoButton versus suture anchor repair of distal biceps tendon injuries.
    Spang JT; Weinhold PS; Karas SG
    J Shoulder Elbow Surg; 2006; 15(4):509-14. PubMed ID: 16831659
    [TBL] [Abstract][Full Text] [Related]  

  • 19. MR imaging in the evaluation of SLAP injuries of the shoulder: findings in 10 patients.
    Cartland JP; Crues JV; Stauffer A; Nottage W; Ryu RK
    AJR Am J Roentgenol; 1992 Oct; 159(4):787-92. PubMed ID: 1529844
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Footprint contact restoration between the biceps-labrum complex and the glenoid rim in SLAP repair: a comparative cadaveric study using pressure-sensitive film.
    Kim SJ; Kim SH; Lee SK; Lee JH; Chun YM
    Arthroscopy; 2013 Jun; 29(6):1005-11. PubMed ID: 23726107
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.