BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 1509076)

  • 1. US-guided percutaneous liver biopsy with plugging of the needle track: a prospective study in 72 high-risk patients.
    Zins M; Vilgrain V; Gayno S; Rolland Y; Arrivé L; Denninger MH; Vullierme MP; Najmark D; Menu Y; Nahum H
    Radiology; 1992 Sep; 184(3):841-3. PubMed ID: 1509076
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Ultrasound-guided percutaneous plugged biopsy of the liver in patients with coagulation disorders. Preliminary report].
    Méndez Gutiérrez TH; Dehesa Violante M; Rodríguez Jerkov J; de la Garza S; González Loya F
    Rev Gastroenterol Mex; 1990; 55(1):13-5. PubMed ID: 2291061
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transjugular biopsy of the liver in pediatric and adult patients using an 18-gauge automated core biopsy needle: a retrospective review of 410 consecutive procedures.
    Smith TP; Presson TL; Heneghan MA; Ryan JM
    AJR Am J Roentgenol; 2003 Jan; 180(1):167-72. PubMed ID: 12490497
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Safety and value of minilaparoscopy in high risk patients].
    Denzer U; Helmreich-Becker I; Galle PR; Lohse AW
    Z Gastroenterol; 2001 Jan; 39(1 Suppl):11-4. PubMed ID: 11216429
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Diagnostic value of transjugular liver biopsy in liver transplant recipients].
    Romero M; Bañares R; Salcedo M; Alvarez E; Peligros I; Clemente G; Cos E
    Gastroenterol Hepatol; 1999 Dec; 22(10):493-6. PubMed ID: 10650662
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy and safety of percutaneous US-guided needle biopsies in specific focal liver lesions: comparison of large and small needles in 1300 patients.
    Aribaş BK; Arda K; Ciledağ N; Aktaş E; Yakut F; Kavak S; Sahin G; Kaygusuz H
    Panminerva Med; 2012 Sep; 54(3):233-9. PubMed ID: 22801441
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A new technical of liver biopsy with plugging of the needle track using a double channel biopsy device. An experimental study.
    Zatloukal K; Dinges HP; Thurnher M; Redl H; Schlag G
    Z Gastroenterol; 1988 Nov; 26(11):699-703. PubMed ID: 2462313
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous US-guided liver biopsy in focal lesions using a semiautomatic device allowing to perform multiple biopsies in a single-pass.
    Tzortzis D; Revenas K; Deladetsima I; Antoniou E; Tzortzis G
    Minerva Gastroenterol Dietol; 2012 Mar; 58(1):1-8. PubMed ID: 22418999
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Percutaneous liver biopsy with plugging of needle track: a safe method for use in patients with impaired coagulation.
    Riley SA; Ellis WR; Irving HC; Lintott DJ; Axon AT; Losowsky MS
    Lancet; 1984 Aug; 2(8400):436. PubMed ID: 6147505
    [No Abstract]   [Full Text] [Related]  

  • 10. Needle biopsy of the liver. A critique of four currently available methods.
    Babb RR; Jackman RJ
    West J Med; 1989 Jan; 150(1):39-42. PubMed ID: 2660406
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Percutaneous imaging-guided solid organ core needle biopsy: coaxial versus noncoaxial method.
    Hatfield MK; Beres RA; Sane SS; Zaleski GX
    AJR Am J Roentgenol; 2008 Feb; 190(2):413-7. PubMed ID: 18212227
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous liver biopsy and track embolization with steel coils.
    Allison DJ; Adam A
    Radiology; 1988 Oct; 169(1):261-3. PubMed ID: 3420270
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Ultrasound-guided thin-needle biopsy in focal liver diseases. II. Benign focal liver diseases].
    Wernecke K; Heckemann R; Rehwald U
    Ultraschall Med; 1984 Dec; 5(6):303-11. PubMed ID: 6098012
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Endoscopic ultrasound-guided fine-needle aspiration biopsy of liver lesions: histological and cytological assessment.
    Hollerbach S; Willert J; Topalidis T; Reiser M; Schmiegel W
    Endoscopy; 2003 Sep; 35(9):743-9. PubMed ID: 12929021
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Plugged liver biopsy in patients with impaired coagulation.
    Tobin MV; Gilmore IT
    Dig Dis Sci; 1989 Jan; 34(1):13-5. PubMed ID: 2910671
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Laparoscopic liver biopsy in patients with coagulopathy, portal hypertension, and ascites.
    Inabnet WB; Deziel DJ
    Am Surg; 1995 Jul; 61(7):603-6. PubMed ID: 7793741
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A combined biopsy-plugging device based on the Menghini- or Trucut needle for percutaneous liver biopsy: clinical experience.
    Judmaier G; Vogel W; Dinges HP; Zatloukal K
    Z Gastroenterol; 1993 Oct; 31(10):614-6. PubMed ID: 8256477
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Liver biopsy methods for pediatric oncology patients.
    Hoffer FA
    Pediatr Radiol; 2000 Jul; 30(7):481-8. PubMed ID: 10929368
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Percutaneous transhepatic liver biopsy with tract embolization.
    Smith TP; McDermott VG; Ayoub DM; Suhocki PV; Stackhouse DJ
    Radiology; 1996 Mar; 198(3):769-74. PubMed ID: 8628869
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Ultrasonically guided fine-needle aspiration of liver lesions.
    Edoute Y; Tibon-Fisher O; Ben Haim S; Malberger E
    Am J Gastroenterol; 1992 Sep; 87(9):1138-41. PubMed ID: 1519570
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.