BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

416 related articles for article (PubMed ID: 15093639)

  • 1. Effect of 1-piece and 3-piece AcrySof intraocular lenses on the development of posterior capsule opacification after cataract surgery.
    Bender LE; Nimsgern C; Jose R; Jayaram H; Spalton DJ; Tetz MR; Packard RB; Meacock W; Boyce J
    J Cataract Refract Surg; 2004 Apr; 30(4):786-9. PubMed ID: 15093639
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Posterior capsule opacification after implantation of a hydrophilic or a hydrophobic acrylic intraocular lens: one-year follow-up.
    Kugelberg M; Wejde G; Jayaram H; Zetterström C
    J Cataract Refract Surg; 2006 Oct; 32(10):1627-31. PubMed ID: 17010858
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Long-term effect of 1-piece and 3-piece hydrophobic acrylic intraocular lens on posterior capsule opacification: a randomized trial.
    Leydolt C; Davidovic S; Sacu S; Menapace R; Neumayer T; Prinz A; Buehl W; Findl O
    Ophthalmology; 2007 Sep; 114(9):1663-9. PubMed ID: 17822973
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of posterior capsule opacification rates between hydrophilic and hydrophobic single-piece acrylic intraocular lenses.
    Heatley CJ; Spalton DJ; Kumar A; Jose R; Boyce J; Bender LE
    J Cataract Refract Surg; 2005 Apr; 31(4):718-24. PubMed ID: 15899448
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of posterior capsule opacification between the 1-piece and 3-piece Acrysof intraocular lenses: two-year results of a randomized trial.
    Sacu S; Findl O; Menapace R; Buehl W; Wirtitsch M
    Ophthalmology; 2004 Oct; 111(10):1840-6. PubMed ID: 15465544
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Posterior capsule opacification after implantation of CeeOn Edge 911A, PhacoFlex SI-40NB, and AcrySof MA60BM lenses: one-year results of an intraindividual comparison multicenter study.
    Mester U; Fabian E; Gerl R; Hunold W; Hütz W; Strobel J; Hoyer H; Kohnen T
    J Cataract Refract Surg; 2004 May; 30(5):978-85. PubMed ID: 15130632
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Two-year follow-up of posterior capsule opacification after implantation of a hydrophilic or hydrophobic acrylic intraocular lens.
    Kugelberg M; Wejde G; Jayaram H; Zetterström C
    Acta Ophthalmol; 2008 Aug; 86(5):533-6. PubMed ID: 18081899
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Posterior capsule opacification in silicone and hydrophobic acrylic intraocular lenses with sharp-edge optics six years after surgery.
    Vock L; Crnej A; Findl O; Neumayer T; Buehl W; Sacu S; Rainer G; Menapace R
    Am J Ophthalmol; 2009 Apr; 147(4):683-690.e2. PubMed ID: 19201391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fellow-eye comparison of posterior capsule opacification with AcrySof SN60AT and AF-1 YA-60BB blue-blocking intraocular lenses.
    Hancox J; Spalton D; Cleary G; Boyce J; Nanavaty MA; Thyagarajan S; Marshall J
    J Cataract Refract Surg; 2008 Sep; 34(9):1489-94. PubMed ID: 18721708
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics: randomized clinical trial.
    Findl O; Menapace R; Sacu S; Buehl W; Rainer G
    Ophthalmology; 2005 Jan; 112(1):67-72. PubMed ID: 15629822
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantification of posterior capsule opacification with round and sharp edge intraocular lenses.
    Auffarth GU; Golescu A; Becker KA; Völcker HE
    Ophthalmology; 2003 Apr; 110(4):772-80. PubMed ID: 12689901
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction.
    Sacu S; Menapace R; Buehl W; Rainer G; Findl O
    J Cataract Refract Surg; 2004 Sep; 30(9):1875-82. PubMed ID: 15342049
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of posterior capsule opacification using a new posterior view method in rabbits: single-piece acrylic versus 3-piece acrylic intraocular lens.
    Nishi O; Nishi K; Osakabe Y
    J Cataract Refract Surg; 2005 Dec; 31(12):2369-74. PubMed ID: 16473233
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Posterior capsule opacification in rabbit eyes implanted with 1-piece and 3-piece hydrophobic acrylic intraocular lenses.
    Werner L; Mamalis N; Izak AM; Pandey SK; Davis BL; Nilson CD; Weight C; Apple DJ
    J Cataract Refract Surg; 2005 Apr; 31(4):805-11. PubMed ID: 15899460
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery.
    Vock L; Menapace R; Stifter E; Georgopoulos M; Sacu S; Bühl W
    J Cataract Refract Surg; 2009 Mar; 35(3):459-65. PubMed ID: 19251138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of 1-piece and 3-piece AcrySof IOLs on the development of PCO after cataract surgery.
    Olson RJ
    J Cataract Refract Surg; 2005 Mar; 31(3):459-60. PubMed ID: 15811724
    [No Abstract]   [Full Text] [Related]  

  • 17. Long-term effect of sharp optic edges of a polymethyl methacrylate intraocular lens on posterior capsule opacification: a randomized trial.
    Findl O; Buehl W; Menapace R; Sacu S; Georgopoulos M; Rainer G
    Ophthalmology; 2005 Nov; 112(11):2004-8. PubMed ID: 16168485
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of optic material and haptic design on anterior capsule opacification and capsulorrhexis contraction.
    Sacu S; Menapace R; Findl O
    Am J Ophthalmol; 2006 Mar; 141(3):488-493. PubMed ID: 16490494
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Randomized intraindividual comparison of posterior capsule opacification between a microincision intraocular lens and a conventional intraocular lens.
    Cleary G; Spalton DJ; Hancox J; Boyce J; Marshall J
    J Cataract Refract Surg; 2009 Feb; 35(2):265-72. PubMed ID: 19185241
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Posterior capsule opacification after extra capsular cataract extraction in Indian rural population: foldable acrylic vs poly (methyl-methacrylate) intraocular lenses a randomized clinical trial.
    Shah AR; Praveen MR; Vasavada AR
    Eye (Lond); 2008 Jul; 22(7):889-94. PubMed ID: 17318205
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.