These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 15104168)

  • 1. Built-in LED contact lens electrode for S-cone electroretinographic recordings.
    Tsuruoka M; Yamamoto S; Ogata K; Hayashi M
    Doc Ophthalmol; 2004 Jan; 108(1):61-6. PubMed ID: 15104168
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Blue light-emitting diode built-in contact lens electrode can record human S-cone electroretinogram.
    Horiguchi M; Miyake Y; Kondo M; Suzuki S; Tanikawa A; Koo HM
    Invest Ophthalmol Vis Sci; 1995 Jul; 36(8):1730-2. PubMed ID: 7601654
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A contact lens electrode with built-in high intensity white light-emitting diodes. A contact lens electrode with built-in white LEDs.
    Kondo M; Piao CH; Tanikawa A; Horiguchi M; Miyake Y
    Doc Ophthalmol; 2001 Jan; 102(1):1-9. PubMed ID: 11475361
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electroretinogram contact lens electrode with tri-color light-emitting diode.
    Mizunoya S; Kuniyoshi K; Arai M; Tahara K; Hirose T
    Acta Ophthalmol Scand; 2001 Oct; 79(5):497-500. PubMed ID: 11594987
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electroretinography of short-wavelength-sensitive cones with a LED built-in electrode and its normal values.
    Kuniyoshi K; Uno N; Irifune M; Shimomura Y
    Doc Ophthalmol; 2003 May; 106(3):311-8. PubMed ID: 12737509
    [TBL] [Abstract][Full Text] [Related]  

  • 6. S-cone ERGs elicited by a simple technique in normals and in tritanopes.
    Arden G; Wolf J; Berninger T; Hogg CR; Tzekov R; Holder GE
    Vision Res; 1999 Feb; 39(3):641-50. PubMed ID: 10341991
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Changes of cone electroretinograms to colour flash stimuli after successful retinal detachment surgery.
    Hayashi M; Yamamoto S
    Br J Ophthalmol; 2001 Apr; 85(4):410-3. PubMed ID: 11264128
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Full-field ERGs obtained using a contact lens electrode with built-in high intensity white light-emitting diodes in beagle dogs can be applied to toxicological assessments.
    Sasaki S; Yamashita H; Yagi K; Iwaki Y; Kimura M
    Toxicol Lett; 2006 Oct; 166(2):115-21. PubMed ID: 16872762
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of Spectral Characteristics of Ganzfeld Stimuli on the Photopic Negative Response (PhNR) of the ERG.
    Rangaswamy NV; Shirato S; Kaneko M; Digby BI; Robson JG; Frishman LJ
    Invest Ophthalmol Vis Sci; 2007 Oct; 48(10):4818-28. PubMed ID: 17898309
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electroretinography using contact lens electrode with built-in light source in dogs.
    Maehara S; Itoh N; Itoh Y; Wakaiki S; Tsuzuki K; Seno T; Kushiro T; Yamashita K; Izumisawa Y; Kotani T
    J Vet Med Sci; 2005 May; 67(5):509-14. PubMed ID: 15942136
    [TBL] [Abstract][Full Text] [Related]  

  • 11. S-cone electroretinogram to Ganzfeld stimuli in patients with retinitis pigmentosa.
    Yamamoto S; Hayashi M; Takeuchi S
    Doc Ophthalmol; 1999; 99(2):183-9. PubMed ID: 11097121
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [The effect of age on short-wavelength sensitive cone electroretinograms and long-and middle-wavelength sensitive cone electroretinograms].
    Suzuki S; Horiguchi M; Miyake Y; Tanikawa A; Kondo M
    Nippon Ganka Gakkai Zasshi; 1997 May; 101(5):434-40. PubMed ID: 9170851
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of age on short-wavelength sensitive cone electroretinogram and long- and middle-wavelength sensitive cone electroretinogram.
    Suzuki S; Horiguchi M; Tanikawa A; Miyake Y; Kondo M
    Jpn J Ophthalmol; 1998; 42(5):424-30. PubMed ID: 9822976
    [TBL] [Abstract][Full Text] [Related]  

  • 14. S-cone electroretinograms in multiple evanescent white dot syndrome.
    Yamamoto S; Hayashi M; Tsuruoka M; Yamamoto T; Tsukahara I; Takeuchi S
    Doc Ophthalmol; 2003 Mar; 106(2):117-20. PubMed ID: 12678275
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cone electroretinogram to chromatic stimuli in myopic eyes.
    Yamamoto S; Nitta K; Kamiyama M
    Vision Res; 1997 Aug; 37(15):2157-9. PubMed ID: 9327063
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Selective reduction of S-cone response and on-response in the cone electroretinograms of patients with X-linked retinoschisis.
    Yamamoto S; Hayashi M; Tsuruoka M; Ogata K; Tsukahara I; Yamamoto T; Takeuchi S
    Graefes Arch Clin Exp Ophthalmol; 2002 Jun; 240(6):457-60. PubMed ID: 12107512
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Colored light stimuli in ERG for differential diagnosis of cone dystrophies].
    Kellner U; Foerster MH
    Klin Monbl Augenheilkd; 1992 Aug; 201(2):102-6. PubMed ID: 1434375
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Full-field electroretinography obtained using a contact lens electrode with built-in high-intensity white-light-emitting diodes can be utilized in toxicological assessments in rats.
    Yamashita H; Yamasaki K; Sugihara K; Miyata H; Tsutsumi S; Iwaki Y
    Ophthalmic Res; 2009; 42(1):15-20. PubMed ID: 19478536
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of ERGs recorded with skin and corneal-contact electrodes in normal children and adults.
    Bradshaw K; Hansen R; Fulton A
    Doc Ophthalmol; 2004 Jul; 109(1):43-55. PubMed ID: 15675199
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of different recording parameters to establish a standard for flash electroretinography in rodents.
    Bayer AU; Cook P; Brodie SE; Maag KP; Mittag T
    Vision Res; 2001 Aug; 41(17):2173-85. PubMed ID: 11448710
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.