These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 15104632)

  • 41. Mechanical comparison of 3.5 mm broad dynamic compression plate, broad limited-contact dynamic compression plate, and narrow locking compression plate systems using interfragmentary gap models.
    Uhl JM; Seguin B; Kapatkin AS; Schulz KS; Garcia TC; Stover SM
    Vet Surg; 2008 Oct; 37(7):663-73. PubMed ID: 19134089
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 3-hole 4.5 mm locking compression plate and 3-hole 4.5 mm narrow dynamic compression plate, with two transarticular 5.5 mm cortex screws.
    Zoppa AL; Santoni B; Puttlitz CM; Cochran K; Hendrickson DA
    Vet Surg; 2011 Feb; 40(2):253-9. PubMed ID: 21244444
    [TBL] [Abstract][Full Text] [Related]  

  • 43. A clinical evaluation of a headless, titanium, variable-pitched, tapered, compression screw for repair of nondisplaced lateral condylar fractures in thoroughbred racehorses.
    Galuppo LD; Simpson EL; Greenman SL; Dowd JP; Ferraro GL; Meagher DM
    Vet Surg; 2006 Jul; 35(5):423-30. PubMed ID: 16842286
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Compression forces generated by Mini bone screws--a comparative study done on bone model.
    Adla DN; Kitsis C; Miles AW
    Injury; 2005 Jan; 36(1):65-70. PubMed ID: 15589916
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Biomechanical comparison of two headless compression screws for scaphoid fixation.
    Pensy RA; Richards AM; Belkoff SM; Mentzer K; Andrew Eglseder W
    J Surg Orthop Adv; 2009; 18(4):182-8. PubMed ID: 19995497
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures.
    Dargel J; Gick S; Mader K; Koebke J; Pennig D
    Injury; 2010 Feb; 41(2):156-60. PubMed ID: 19665707
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Surgical management of proximal splint bone fractures in the horse.
    Peterson PR; Pascoe JR; Wheat JD
    Vet Surg; 1987; 16(5):367-72. PubMed ID: 3507168
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Lag screw stabilization of a cervical vertebral fracture by use of computed tomography in a horse.
    Barnes HG; Tucker RL; Grant BD; Roberts GD; Prades M
    J Am Vet Med Assoc; 1995 Jan; 206(2):221-3. PubMed ID: 7751226
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Lag screw fixation of dorsal cortical stress fractures of the third metacarpal bone in 116 racehorses.
    Jalim SL; McIlwraith CW; Goodman NL; Anderson GA
    Equine Vet J; 2010 Oct; 42(7):586-90. PubMed ID: 20840573
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Surgical repair of a supraglenoid tubercle fracture in a horse.
    Adams SB
    J Am Vet Med Assoc; 1987 Aug; 191(3):332-4. PubMed ID: 3654298
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Dynamics of screw and plate interaction.
    Johnson KA
    Vet Comp Orthop Traumatol; 2011; 24(6):III-IV. PubMed ID: 22089032
    [No Abstract]   [Full Text] [Related]  

  • 52. Headless compression screw fixation of scaphoid fractures.
    Fowler JR; Ilyas AM
    Hand Clin; 2010 Aug; 26(3):351-61, vi. PubMed ID: 20670800
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Fixation strength of anteriorly inserted headless screws for talar neck fractures.
    Capelle JH; Couch CG; Wells KM; Morris RP; Buford WL; Merriman DJ; Panchbhavi VK
    Foot Ankle Int; 2013 Jul; 34(7):1012-6. PubMed ID: 23456083
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Tension-band wiring and lag screw fixation of a transverse, comminuted fracture of a patella in a horse.
    Hunt RJ; Baxter GM; Zamos DT
    J Am Vet Med Assoc; 1992 Mar; 200(6):819-20. PubMed ID: 1568930
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Mechanical comparison of 3 different clamp and 2 different rod types of a new veterinary internal fixation system, 4.5/5.5-mm VetFix.
    Haerdi C; Costa RD; Auer JA; Linke B; Steiner A
    Vet Surg; 2003; 32(5):431-8. PubMed ID: 14569571
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Double-plate fixation of comminuted fractures of the second phalanx in horses: 10 cases (1985-1993).
    Crabill MR; Watkins JP; Schneider RK; Auer JA
    J Am Vet Med Assoc; 1995 Dec; 207(11):1458-61. PubMed ID: 7493876
    [TBL] [Abstract][Full Text] [Related]  

  • 57. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.
    Sod GA; Riggs LM; Mitchell CF; Hubert JD; Martin GS
    Vet Surg; 2010 Jan; 39(1):83-90. PubMed ID: 20210950
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Surgical removal of an apical fragment of a fractured proximal sesamoid bone (and a retrieval procedure).
    Asquith RL
    Vet Med Small Anim Clin; 1979 Apr; 74(4):571-2. PubMed ID: 256384
    [No Abstract]   [Full Text] [Related]  

  • 59. Clinical use of computed tomography and surface markers to assist internal fixation within the equine hoof.
    Gasiorowski JC; Richardson DW
    Vet Surg; 2015 Feb; 44(2):214-22. PubMed ID: 25132168
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones using bioabsorbable screws.
    Mageed M; Steinberg T; Drumm N; Stubbs N; Wegert J; Koene M
    Aust Vet J; 2018 Mar; 96(3):76-81. PubMed ID: 29479686
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.