473 related articles for article (PubMed ID: 15108829)
21. Difficulties in spinal needle use. Insertion characteristics and failure rates associated with 25-, 27- and 29-gauge Quincke-type spinal needles.
Tarkkila P; Huhtala J; Salminen U
Anaesthesia; 1994 Aug; 49(8):723-5. PubMed ID: 7943709
[TBL] [Abstract][Full Text] [Related]
22. [The effect of needle type and immobilization on postspinal headache].
Hafer J; Rupp D; Wollbrück M; Engel J; Hempelmann G
Anaesthesist; 1997 Oct; 46(10):860-6. PubMed ID: 9424969
[TBL] [Abstract][Full Text] [Related]
23. Lower incidence of postdural puncture headache using whitacre spinal needles after spinal anesthesia: A meta-analysis.
Zhang D; Chen L; Chen X; Wang X; Li Y; Ning G; Feng S
Headache; 2016 Mar; 56(3):501-10. PubMed ID: 26952012
[TBL] [Abstract][Full Text] [Related]
24. [Comparison of efficacy and complications of 27G and 29G Sprottte needles for subarachnoid anesthesia].
Morros-Viñoles C; Pérez-Cuenca MD; Cedó-Lluís E; Colls C; Bueno J; Cedó-Vallobá F
Rev Esp Anestesiol Reanim; 2002 Nov; 49(9):448-54. PubMed ID: 12516488
[TBL] [Abstract][Full Text] [Related]
25. Post-dural puncture headache in young orthopaedic in-patients: comparison of a 0.33 mm (29-gauge) Quincke-type with a 0.7 mm (22-gauge) Whitacre spinal needle in 200 patients.
Lynch J; Arhelger S; Krings-Ernst I
Acta Anaesthesiol Scand; 1992 Jan; 36(1):58-61. PubMed ID: 1539481
[TBL] [Abstract][Full Text] [Related]
26. Spinal anaesthesia for caesarean section: comparison of 22-gauge and 25-gauge Whitacre needles with 26-gauge Quincke needles.
Shutt LE; Valentine SJ; Wee MY; Page RJ; Prosser A; Thomas TA
Br J Anaesth; 1992 Dec; 69(6):589-94. PubMed ID: 1467102
[TBL] [Abstract][Full Text] [Related]
27. Spinal needle design and size affect the incidence of postdural puncture headache in children.
Apiliogullari S; Duman A; Gok F; Akillioglu I
Paediatr Anaesth; 2010 Feb; 20(2):177-82. PubMed ID: 20015139
[TBL] [Abstract][Full Text] [Related]
28. Grading of severity of postdural puncture headache after 27-gauge Quincke and Whitacre needles.
Corbey MP; Bach AB; Lech K; Frørup AM
Acta Anaesthesiol Scand; 1997 Jun; 41(6):779-84. PubMed ID: 9241342
[TBL] [Abstract][Full Text] [Related]
29. Postdural puncture headache and spinal needle design. Metaanalyses.
Halpern S; Preston R
Anesthesiology; 1994 Dec; 81(6):1376-83. PubMed ID: 7992906
[TBL] [Abstract][Full Text] [Related]
30. Spinal anesthesia in outpatient knee surgery: 22-gauge versus 25-gauge Sprotte needle.
Pittoni G; Toffoletto F; Calcarella G; Zanette G; Giron GP
Anesth Analg; 1995 Jul; 81(1):73-9. PubMed ID: 7598286
[TBL] [Abstract][Full Text] [Related]
31. The effect of spinal needle design, size, and penetration angle on dural puncture cerebral spinal fluid loss.
O'Connor G; Gingrich R; Moffat M
AANA J; 2007 Apr; 75(2):111-6. PubMed ID: 17471881
[TBL] [Abstract][Full Text] [Related]
32. Sprotte needle for obstetric anesthesia: decreased incidence of post dural puncture headache.
Ross BK; Chadwick HS; Mancuso JJ; Benedetti C
Reg Anesth; 1992; 17(1):29-33. PubMed ID: 1599891
[TBL] [Abstract][Full Text] [Related]
33. Post dural puncture headache in cesarean section: comparison of 25-gauge Whitacre with 25- and 26-gauge Quincke needles.
Hwang JJ; Ho ST; Wang JJ; Liu HS
Acta Anaesthesiol Sin; 1997 Mar; 35(1):33-7. PubMed ID: 9212479
[TBL] [Abstract][Full Text] [Related]
34. Needle gauge and tip designs for preventing post-dural puncture headache (PDPH).
Arevalo-Rodriguez I; Muñoz L; Godoy-Casasbuenas N; Ciapponi A; Arevalo JJ; Boogaard S; Roqué I Figuls M
Cochrane Database Syst Rev; 2017 Apr; 4(4):CD010807. PubMed ID: 28388808
[TBL] [Abstract][Full Text] [Related]
35. Does Atraucan cause more postdural puncture backache?
Abdullayev R; Küçükebe OB; Çelik B; Kirman N; Hatipoğlu HS; Akaltun Hatipoğlu F
Turk J Med Sci; 2015; 45(4):877-81. PubMed ID: 26422861
[TBL] [Abstract][Full Text] [Related]
36. Comparison of the 25-gauge Whitacre with the 24-gauge Sprotte spinal needle for elective caesarean section: cost implications.
Campbell DC; Douglas MJ; Pavy TJ; Merrick P; Flanagan ML; McMorland GH
Can J Anaesth; 1993 Dec; 40(12):1131-5. PubMed ID: 8281588
[TBL] [Abstract][Full Text] [Related]
37. Whitacre or Quincke needles--does it really matter.
Eriksson AL; Hallén B; Lagerkranser M; Persson E; Sköldefors E
Acta Anaesthesiol Scand Suppl; 1998; 113():17-20. PubMed ID: 9932114
[TBL] [Abstract][Full Text] [Related]
38. Postdural puncture headache after continuous spinal anesthesia with 18-gauge and 20-gauge needles.
Mazze RI; Fujinaga M
Reg Anesth; 1993; 18(1):47-51. PubMed ID: 8448099
[TBL] [Abstract][Full Text] [Related]
39. Post-dural puncture headache in young patients. A comparative study between the use of 0.52 mm (25-gauge) and 0.33 mm (29-gauge) spinal needles.
Geurts JW; Haanschoten MC; van Wijk RM; Kraak H; Besse TC
Acta Anaesthesiol Scand; 1990 Jul; 34(5):350-3. PubMed ID: 2143882
[TBL] [Abstract][Full Text] [Related]
40. Post-dural puncture headache: a comparison of the Sprotte and Yale needles in urological surgery.
Harrison DA; Langham BT
Eur J Anaesthesiol; 1994 Jul; 11(4):325-7. PubMed ID: 7925339
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]