BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

387 related articles for article (PubMed ID: 15109756)

  • 1. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication.
    Mabuchi K; Sakai R; Ota M; Ujihira M
    Clin Biomech (Bristol, Avon); 2004 May; 19(4):362-9. PubMed ID: 15109756
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements.
    Gao L; Wang F; Yang P; Jin Z
    Med Eng Phys; 2009 Jul; 31(6):720-9. PubMed ID: 19269879
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    J Biomech; 2006; 39(5):905-14. PubMed ID: 16199048
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin Z; Roberts P; Grigoris P
    J Biomech; 2007; 40(6):1340-9. PubMed ID: 16824529
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses.
    Hu XQ; Isaac GH; Fisher J
    Biomed Mater Eng; 2004; 14(2):145-9. PubMed ID: 15156105
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Elastohydrodynamic lubrication analysis of metal-on-metal hip-resurfacing prostheses.
    Udofia IJ; Jin ZM
    J Biomech; 2003 Apr; 36(4):537-44. PubMed ID: 12600344
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses.
    Liu F; Jin Z; Roberts P; Grigoris P
    Proc Inst Mech Eng H; 2006 Aug; 220(6):695-704. PubMed ID: 16961189
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of elastohydrodynamic lubrication in McKee-Farrar metal-on-metal hip joint replacement.
    Yew A; Udofia I; Jagatia M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):27-34. PubMed ID: 14982343
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Calculation of theoretical lubrication regimes in two-piece first metatarsophalangeal prostheses.
    Joyce TJ
    Biomed Mater Eng; 2008; 18(1):45-51. PubMed ID: 18198406
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface.
    Meng Q; Gao L; Liu F; Yang P; Fisher J; Jin Z
    J Biomech; 2010 Mar; 43(5):849-57. PubMed ID: 20003978
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint.
    Scholes SC; Burgess IC; Marsden HR; Unsworth A; Jones E; Smith N
    Proc Inst Mech Eng H; 2006 Jul; 220(5):583-96. PubMed ID: 16898216
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [FE-analysis of surface stresses for the tribological system in total hip prostheses].
    Behrens BA; Helms G; Pösse O; Nolte I; Meyer-Lindenberg A; Rittmann P; Windhagen H; Pressel T
    Biomed Tech (Berl); 2006 Dec; 51(5-6):367-70. PubMed ID: 17155874
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wear properties of alumina/zirconia composite ceramics for joint prostheses measured with an end-face apparatus.
    Morita Y; Nakata K; Kim YH; Sekino T; Niihara K; Ikeuchi K
    Biomed Mater Eng; 2004; 14(3):263-70. PubMed ID: 15299238
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
    Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
    Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses.
    Mak M; Jin Z; Fisher J; Stewart TD
    J Arthroplasty; 2011 Jan; 26(1):131-6. PubMed ID: 20149581
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear.
    Williams S; Jalali-Vahid D; Brockett C; Jin Z; Stone MH; Ingham E; Fisher J
    J Biomech; 2006; 39(12):2274-81. PubMed ID: 16143337
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Elastohydrodynamic lubrication analysis of ultra-high molecular weight polyethylene hip joint replacements under squeeze-film motion.
    Jagatia M; Jalali-Vahid D; Jin ZM
    Proc Inst Mech Eng H; 2001; 215(2):141-52. PubMed ID: 11382073
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prediction of lubrication regimes in two-piece metacarpophalangeal prostheses.
    Joyce TJ
    Med Eng Phys; 2007 Jan; 29(1):87-92. PubMed ID: 16877022
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design aspects of compliant, soft layer bearings for an experimental hip prosthesis.
    Scholes SC; Unsworth A; Blamey JM; Burgess IC; Jones E; Smith N
    Proc Inst Mech Eng H; 2005; 219(2):79-87. PubMed ID: 15819479
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions.
    Al-Hajjar M; Fisher J; Tipper JL; Williams S; Jennings LM
    Proc Inst Mech Eng H; 2013 May; 227(5):535-42. PubMed ID: 23637263
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.