BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

250 related articles for article (PubMed ID: 15110307)

  • 1. A comparison of the precision of seeds deposited as loose seeds versus suture embedded seeds: a randomized trial.
    Kaplan ID; Meskell PM; Lieberfarb M; Saltzman B; Berg S; Holupka EJ
    Brachytherapy; 2004; 3(1):7-9. PubMed ID: 15110307
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improvements in prostate brachytherapy dosimetry due to seed stranding.
    Lin K; Lee SP; Cho JS; Reiter RE; DeMarco JJ; Solberg TD
    Brachytherapy; 2007; 6(1):44-8. PubMed ID: 17284385
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of the radial function on I-125 seeds used for permanent prostate implantation.
    Pickett B; Pouliot J
    Med Dosim; 2004; 29(3):204-9. PubMed ID: 15324917
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparative study of seed localization and dose calculation on pre- and post-implantation ultrasound and CT images for low-dose-rate prostate brachytherapy.
    Ali I; Algan O; Thompson S; Sindhwani P; Herman T; Cheng CY; Ahmad S
    Phys Med Biol; 2009 Sep; 54(18):5595-611. PubMed ID: 19717887
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Technical improvement in permanent seed implantation: a two-stage brachytherapy system. Description and comparison with current technique.
    Grimm PD; Blasko JC; Sylvester JE; Heaney C; Gasparich J; Quackenbush J; Gottesman J; Downey J; Grier D; Roddy T; Nellans R; Sood N; Wahl D
    Brachytherapy; 2004; 3(1):34-40. PubMed ID: 15110312
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetry accuracy as a function of seed localization uncertainty in permanent prostate brachytherapy: increased seed number correlates with less variability in prostate dosimetry.
    Su Y; Davis BJ; Furutani KM; Herman MG; Robb RA
    Phys Med Biol; 2007 Jun; 52(11):3105-19. PubMed ID: 17505092
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Commentary on "a comparison of the precision of seeds deposited as loose seeds vs. suture-embedded seeds: a randomized trial" and "prostate brachytherapy seed migration and dosimetry: analysis of stranded sources and other potential predictive factors": to strand or not to strand--is this really the question?
    Crook J
    Brachytherapy; 2004; 3(1):20-1. PubMed ID: 15110309
    [No Abstract]   [Full Text] [Related]  

  • 8. Loose seeds vs. stranded seeds: a comparison of critical organ dosimetry and acute toxicity in (125)I permanent implant for low-risk prostate cancer.
    Saibishkumar EP; Borg J; Yeung I; Cummins-Holder C; Landon A; Crook JM
    Brachytherapy; 2008; 7(2):200-5. PubMed ID: 18362087
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sequential comparison of seed loss and prostate dosimetry of stranded seeds with loose seeds in 125I permanent implant for low-risk prostate cancer.
    Saibishkumar EP; Borg J; Yeung I; Cummins-Holder C; Landon A; Crook J
    Int J Radiat Oncol Biol Phys; 2009 Jan; 73(1):61-8. PubMed ID: 18823713
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Variability of prostate brachytherapy pre-implant dosimetry: a multi-institutional analysis.
    Merrick GS; Butler WM; Wallner KE; Blasko JC; Michalski J; Aronowitz J; Grimm P; Moran BJ; McLaughlin PW; Usher J; Lief JH; Allen ZA
    Brachytherapy; 2005; 4(4):241-51. PubMed ID: 16344253
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Toward a dynamic real-time intraoperative permanent prostate brachytherapy methodology.
    Potters L; Calguaru E; Thornton KB; Jackson T; Huang D
    Brachytherapy; 2003; 2(3):172-80. PubMed ID: 15062140
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Physical basics and clinical realization of interstitial brachytherapy of the prostate with iodine 125].
    Kaulich TW; Lamprecht U; Paulsen F; Kahmann F; Maurer U; Henkel TO; Loeser W; Bichler KH; Nüsslin F; Bamberg M
    Strahlenther Onkol; 2002 Oct; 178(10):548-55. PubMed ID: 12386786
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is there a role for postimplant dosimetry after real-time dynamic permanent prostate brachytherapy?
    Potters L; Calugaru E; Jassal A; Presser J
    Int J Radiat Oncol Biol Phys; 2006 Jul; 65(4):1014-9. PubMed ID: 16682144
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of CT- and radiograph-based post-implant dosimetry for transperineal 125I prostate brachytherapy using single seeds and a commercial treatment-planning software.
    Siebert FA; Kohr P; Kovács G
    Strahlenther Onkol; 2006 Feb; 182(2):96-101. PubMed ID: 16447016
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Novel prostate brachytherapy technique: improved dosimetric and clinical outcome.
    Nobes JP; Khaksar SJ; Hawkins MA; Cunningham MJ; Langley SE; Laing RW
    Radiother Oncol; 2008 Jul; 88(1):121-6. PubMed ID: 18499289
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prostate brachytherapy seed migration and dosimetry: analysis of stranded sources and other potential predictive factors.
    Fuller DB; Koziol JA; Feng AC
    Brachytherapy; 2004; 3(1):10-9. PubMed ID: 15110308
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraoperative real-time planned conformal prostate brachytherapy: post-implantation dosimetric outcome and clinical implications.
    Zelefsky MJ; Yamada Y; Cohen GN; Sharma N; Shippy AM; Fridman D; Zaider M
    Radiother Oncol; 2007 Aug; 84(2):185-9. PubMed ID: 17692978
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Can the cost of permanent prostate implants be reduced? An argument for peripheral loading with higher strength seeds.
    Maguire PD; Waterman FM; Dicker AP
    Tech Urol; 2000 Jun; 6(2):85-8. PubMed ID: 10798805
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A dosimetric analysis of unstranded seeds versus customized stranded seeds in transperineal interstitial permanent prostate seed brachytherapy.
    Heysek RV; Gwede CK; Torres-Roca J; Cantor A; Kelley S; Saini AS; Pow-Sang J
    Brachytherapy; 2006; 5(4):244-50. PubMed ID: 17118318
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Is a loose-seed nomogram still valid for prostate brachytherapy in a stranded-seed era?
    Kudchadker RJ; Swanson DA; Kuban DA; Lee AK; Bruno TL; Frank SJ
    Int J Radiat Oncol Biol Phys; 2008 Oct; 72(2):623-7. PubMed ID: 18410998
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.