265 related articles for article (PubMed ID: 15113344)
1. Development of a novel polyimide hollow-fiber oxygenator.
Niwa M; Kawakami H; Nagaoka S; Kanamori T; Morisaku K; Shinbo T; Matsuda T; Sakai K; Kubota S
Artif Organs; 2004 May; 28(5):487-95. PubMed ID: 15113344
[TBL] [Abstract][Full Text] [Related]
2. Development of a fluorinated polyimide hollow fiber for medical devices.
Kawakami H; Kanamori T; Kubota S
J Artif Organs; 2003; 6(2):124-9. PubMed ID: 14598113
[TBL] [Abstract][Full Text] [Related]
3. Development of a novel polyimide hollow fiber for an intravascular oxygenator.
Kawakami H; Mori Y; Takagi J; Nagaoka S; Kanamori T; Shinbo T; Kubota S
ASAIO J; 1997; 43(5):M490-4. PubMed ID: 9360091
[TBL] [Abstract][Full Text] [Related]
4. Gas transfer and blood compatibility of asymmetric polyimide hollow fiber.
Niwa M; Kawakami H; Kanno M; Nagaoka S; Kanamori T; Shinbo T; Kubota S
J Biomater Sci Polym Ed; 2001; 12(5):533-42. PubMed ID: 11469783
[TBL] [Abstract][Full Text] [Related]
5. Development of a membrane oxygenator for ECMO using a novel fine silicone hollow fiber.
Funakubo A; Higami T; Sakuma I; Fukui Y; Kawamura T; Sato K; Sueoka A; Nosé Y
ASAIO J; 1996; 42(5):M837-40. PubMed ID: 8945001
[TBL] [Abstract][Full Text] [Related]
6. Performance of a MedArray silicone hollow fiber oxygenator.
LaFayette NG; Schewe RE; Montoya JP; Cook KE
ASAIO J; 2009; 55(4):382-7. PubMed ID: 19381081
[TBL] [Abstract][Full Text] [Related]
7. Estimate of gas transfer rates of an intravascular membrane oxygenator.
Kanamori T; Niwa M; Kawakami H; Mori Y; Nagaoka S; Haraya K; Shinbo T
ASAIO J; 2000; 46(5):612-9. PubMed ID: 11016518
[TBL] [Abstract][Full Text] [Related]
8. Computer-assisted numerical analysis for oxygen and carbon dioxide mass transfer in blood oxygenators.
Turri F; Yanagihara JI
Artif Organs; 2011 Jun; 35(6):579-92. PubMed ID: 21671959
[TBL] [Abstract][Full Text] [Related]
9. Gas transfer and in vitro and in vivo blood compatibility of a fluorinated polyimide membrane with an ultrathin skin layer.
Kawakami H; Nagaoka S; Kubota S
ASAIO J; 1996; 42(5):M871-6. PubMed ID: 8945009
[TBL] [Abstract][Full Text] [Related]
10. Development of a new silicone membrane oxygenator for ECMO.
Nakata K; Maeda T; Murabayashi S; Yoshikawa M; Takano T; Iwasaki A; Nonaka K; Linneweber J; Kawahito S; Glueck J; Sato K; Kuwana J; Nosé Y
Ann Thorac Cardiovasc Surg; 2000 Dec; 6(6):373-7. PubMed ID: 11173351
[TBL] [Abstract][Full Text] [Related]
11. Development of an intravenous membrane oxygenator: a new concept in mechanical support for the failing lung.
Hattler BG; Reeder GD; Sawzik PJ; Walters FR; Pham SM; Kormos RL; Keenan RJ; Griffith BP; Armitage JM; Hardesty RL
J Heart Lung Transplant; 1994; 13(6):1003-8. PubMed ID: 7865505
[TBL] [Abstract][Full Text] [Related]
12. Functional and biocompatibility performances of an integrated Maglev pump-oxygenator.
Zhang T; Cheng G; Koert A; Zhang J; Gellman B; Yankey GK; Satpute A; Dasse KA; Gilbert RJ; Griffith BP; Wu ZJ
Artif Organs; 2009 Jan; 33(1):36-45. PubMed ID: 19178439
[TBL] [Abstract][Full Text] [Related]
13. Development of a new hollow fiber silicone membrane oxygenator for ECMO: the recent progress.
Kawahito S; Motomura T; Glueck J; Nosé Y
Ann Thorac Cardiovasc Surg; 2002 Oct; 8(5):268-74. PubMed ID: 12472408
[TBL] [Abstract][Full Text] [Related]
14. Morphological studies on the culture of kidney epithelial cells in a fiber-in-fiber bioreactor design with hollow fiber membranes.
Fey-Lamprecht F; Albrecht W; Groth T; Weigel T; Gross U
J Biomed Mater Res A; 2003 May; 65(2):144-57. PubMed ID: 12734806
[TBL] [Abstract][Full Text] [Related]
15. Intravascular blood oxygenation using hollow fibers in a disk-shaped configuration: experimental evaluation of the relationship between porosity and performance.
Cattaneo GF; Reul H; Schmitz-Rode T; Steinseifer U
ASAIO J; 2006; 52(2):180-5. PubMed ID: 16557105
[TBL] [Abstract][Full Text] [Related]
16. Feasibility of a new hollow fiber silicone membrane oxygenator for long-term ECMO application.
Kawahito S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Ishitoya H; Hanazaki K; Glueck J; Sato K; Nosé Y
J Med Invest; 2002 Aug; 49(3-4):156-62. PubMed ID: 12323005
[TBL] [Abstract][Full Text] [Related]
17. [Field parameter studies of hollow fiber membrane oxygenator systems for extracorporeal blood circulation].
Liebrecht K; Uhlemann J; Kahnig R; Schmidt V; Freyer R; St Schüler S
Biomed Tech (Berl); 1998; 43 Suppl():330-1. PubMed ID: 9859384
[No Abstract] [Full Text] [Related]
18. Development of an implantable oxygenator with cross-flow pump.
Asakawa Y; Funakubo A; Fukunaga K; Taga I; Higami T; Kawamura T; Fukui Y
ASAIO J; 2006; 52(3):291-5. PubMed ID: 16760718
[TBL] [Abstract][Full Text] [Related]
19. Development of an intravenous membrane oxygenator: enhanced intravenous gas exchange through convective mixing of blood around hollow fiber membranes.
Hattler BG; Reeder GD; Sawzik PJ; Lund LW; Walters FR; Shah AS; Rawleigh J; Goode JS; Klain M; Borovetz HS
Artif Organs; 1994 Nov; 18(11):806-12. PubMed ID: 7864728
[TBL] [Abstract][Full Text] [Related]
20. Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators.
Vaslef SN; Mockros LF; Anderson RW; Leonard RJ
ASAIO J; 1994; 40(4):990-6. PubMed ID: 7858338
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]