BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

659 related articles for article (PubMed ID: 15116032)

  • 1. Influence of occlusal forces on stress distribution in preloaded dental implant screws.
    Alkan I; Sertgöz A; Ekici B
    J Prosthet Dent; 2004 Apr; 91(4):319-25. PubMed ID: 15116032
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Wave analysis of implant screw loosening using an air cylindrical cyclic loading device.
    Lee J; Kim YS; Kim CW; Han JS
    J Prosthet Dent; 2002 Oct; 88(4):402-8. PubMed ID: 12447217
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element analysis to determine implant preload.
    Lang LA; Kang B; Wang RF; Lang BR
    J Prosthet Dent; 2003 Dec; 90(6):539-46. PubMed ID: 14668754
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A Comparison of Torque Stress on Abutment Screw of External Hexagon and Morse Taper Implant.
    Rodrigues EDS; Benetti P; Carli JP; Paranhos LR; Santos PL; Linden MS
    J Contemp Dent Pract; 2018 Nov; 19(11):1306-1311. PubMed ID: 30602632
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The dynamic natures of implant loading.
    Wang RF; Kang B; Lang LA; Razzoog ME
    J Prosthet Dent; 2009 Jun; 101(6):359-71. PubMed ID: 19463663
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical evaluation of screw- and cement-retained implant-supported prostheses: a nonlinear finite element analysis.
    Silva GC; Cornacchia TM; de Magalhães CS; Bueno AC; Moreira AN
    J Prosthet Dent; 2014 Dec; 112(6):1479-88. PubMed ID: 25062583
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vitro evaluation of reverse torque value of abutment screw and marginal opening in a screw- and cement-retained implant fixed partial denture design.
    Kim SG; Park JU; Jeong JH; Bae C; Bae TS; Chee W
    Int J Oral Maxillofac Implants; 2009; 24(6):1061-7. PubMed ID: 20162110
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A finite element analysis of two different dental implants: stress distribution in the prosthesis, abutment, implant, and supporting bone.
    Quaresma SE; Cury PR; Sendyk WR; Sendyk C
    J Oral Implantol; 2008; 34(1):1-6. PubMed ID: 18390236
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of abutment screw preload in two implant connection systems: A 3D finite element study.
    Jung WK; Lee WS; Kwon HB
    J Prosthet Dent; 2019 Nov; 122(5):474.e1-474.e8. PubMed ID: 31590980
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of stiffness of implant-abutment connection on load-deflection ratios of a screw-retained stiff cantilever beam. 3-D measurements in vitro.
    Cassel B; Lundgren D; Karlsson D
    Clin Oral Implants Res; 2013 Nov; 24(11):1251-6. PubMed ID: 22906410
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Photoelastic stress analysis of implant-tooth connected prostheses with segmented and nonsegmented abutments.
    Ochiai KT; Ozawa S; Caputo AA; Nishimura RD
    J Prosthet Dent; 2003 May; 89(5):495-502. PubMed ID: 12806328
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of platform connection and abutment material on stress distribution in single anterior implant-supported restorations: a nonlinear 3-dimensional finite element analysis.
    Carvalho MA; Sotto-Maior BS; Del Bel Cury AA; Pessanha Henriques GE
    J Prosthet Dent; 2014 Nov; 112(5):1096-102. PubMed ID: 24831744
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stress distribution in the abutment and retention screw of a single implant supporting a prosthesis with platform switching.
    Alvarez-Arenal A; Segura-Mori L; Gonzalez-Gonzalez I; Gago A
    Int J Oral Maxillofac Implants; 2013; 28(3):e112-21. PubMed ID: 23748329
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nonlinear contact analysis of preload in dental implant screws.
    Sakaguchi RL; Borgersen SE
    Int J Oral Maxillofac Implants; 1995; 10(3):295-302. PubMed ID: 7615325
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis.
    Bulaqi HA; Mousavi Mashhadi M; Safari H; Samandari MM; Geramipanah F
    J Prosthet Dent; 2015 Jun; 113(6):548-57. PubMed ID: 25794917
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of different implant angulations on the biomechanical performance of prosthetic screws in two implant-supported, screw-retained prostheses: A numerical and experimental study.
    Chen J; Guo J; Yang L; Wang L; Zhang X
    J Prosthet Dent; 2023 Aug; 130(2):240.e1-240.e10. PubMed ID: 37419710
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Nonlinear finite element analysis of a splinted implant with various connectors and occlusal forces.
    Lin CL; Wang JC
    Int J Oral Maxillofac Implants; 2003; 18(3):331-40. PubMed ID: 12814307
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of Implant Inclination and Prosthetic Abutment Type on the Biomechanics of Implant-Supported Fixed Partial Dentures.
    Poletto-Neto V; Tretto PHW; Zen BM; Bacchi A; Dos Santos MBF
    J Oral Implantol; 2019 Oct; 45(5):343-350. PubMed ID: 31429636
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of tightening torque on screw stress and formation of implant-abutment microgaps: A finite element analysis.
    Honório Tonin BS; He Y; Ye N; Chew HP; Fok A
    J Prosthet Dent; 2022 Jun; 127(6):882-889. PubMed ID: 33472752
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant. A nonlinear finite element stress analysis.
    Akça K; Cehreli MC; Iplikçioğlu H
    Clin Oral Implants Res; 2003 Aug; 14(4):444-54. PubMed ID: 12869007
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 33.