228 related articles for article (PubMed ID: 15119457)
1. Technique for achieving a passive framework fit: a clinical case report.
Swallow ST
J Oral Implantol; 2004; 30(2):83-92. PubMed ID: 15119457
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of the accuracy of three techniques used for multiple implant abutment impressions.
Vigolo P; Majzoub Z; Cordioli G
J Prosthet Dent; 2003 Feb; 89(2):186-92. PubMed ID: 12616240
[TBL] [Abstract][Full Text] [Related]
3. Effect of splinted and nonsplinted impression techniques on the accuracy of fit of fixed implant prostheses in edentulous patients: a comparative study.
Papaspyridakos P; Lal K; White GS; Weber HP; Gallucci GO
Int J Oral Maxillofac Implants; 2011; 26(6):1267-72. PubMed ID: 22167432
[TBL] [Abstract][Full Text] [Related]
4. Improving implant framework passive fit and accuracy through the use of verification stents and casts.
Schneider A; Kurtzman GM; Silverstein LH
J Dent Technol; 2001 Jun; 18(4):23-5. PubMed ID: 11933718
[TBL] [Abstract][Full Text] [Related]
5. Metal-ceramic screw-retained implant fixed partial denture with intraoral luted framework to improve passive fit.
Baig MR; Gunaseelan R
J Oral Implantol; 2012 Apr; 38(2):149-53. PubMed ID: 20932151
[TBL] [Abstract][Full Text] [Related]
6. Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster.
Wise M
J Prosthet Dent; 2001 Nov; 86(5):532-8. PubMed ID: 11725282
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments.
Naconecy MM; Teixeira ER; Shinkai RS; Frasca LC; Cervieri A
Int J Oral Maxillofac Implants; 2004; 19(2):192-8. PubMed ID: 15101589
[TBL] [Abstract][Full Text] [Related]
8. Accuracy of impression and pouring techniques for an implant-supported prosthesis.
Del'Acqua MA; Arioli-Filho JN; Compagnoni MA; Mollo Fde A
Int J Oral Maxillofac Implants; 2008; 23(2):226-36. PubMed ID: 18548918
[TBL] [Abstract][Full Text] [Related]
9. Accuracy of different impression techniques for internal-connection implants.
Lee YJ; Heo SJ; Koak JY; Kim SK
Int J Oral Maxillofac Implants; 2009; 24(5):823-30. PubMed ID: 19865622
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of the accuracy of implant-level impression techniques for internal-connection implant prostheses in parallel and divergent models.
Choi JH; Lim YJ; Yim SH; Kim CW
Int J Oral Maxillofac Implants; 2007; 22(5):761-8. PubMed ID: 17974110
[TBL] [Abstract][Full Text] [Related]
11. A combined impression technique for a partial implant-supported fixed-detachable restoration.
Kohavi D
Quintessence Int; 1997 Mar; 28(3):177-81. PubMed ID: 9452684
[TBL] [Abstract][Full Text] [Related]
12. Use of an extraoral verification template for dental implant-supported prostheses.
Silverstein LH; Kurtzman GM; Schneider A; Shatz PC
J Oral Implantol; 2002; 28(4):184-8. PubMed ID: 12498465
[TBL] [Abstract][Full Text] [Related]
13. The influence of verification jig on framework fit for nonsegmented fixed implant-supported complete denture.
Ercoli C; Geminiani A; Feng C; Lee H
Clin Implant Dent Relat Res; 2012 May; 14 Suppl 1():e188-95. PubMed ID: 22176765
[TBL] [Abstract][Full Text] [Related]
14. Full-arch metal-resin cement- and screw-retained provisional restoration for immediately loaded implants.
Baig MR; Rajan G
J Oral Implantol; 2010; 36(3):219-23. PubMed ID: 20553176
[TBL] [Abstract][Full Text] [Related]
15. Accuracy of impressions for internal-connection implant prostheses with various divergent angles.
Jang HK; Kim S; Shim JS; Lee KW; Moon HS
Int J Oral Maxillofac Implants; 2011; 26(5):1011-5. PubMed ID: 22010084
[TBL] [Abstract][Full Text] [Related]
16. The effect of different screw-tightening techniques on the strain generated on an internal-connection implant superstructure. Part 2: Models created with a splinted impression technique.
Choi JH
Int J Oral Maxillofac Implants; 2011; 26(5):1016-23. PubMed ID: 22010085
[TBL] [Abstract][Full Text] [Related]
17. Master cast implant impression: using the open-tray technique.
Briley TF
Dent Implantol Update; 2002 Oct; 13(10):73-80. PubMed ID: 12455316
[No Abstract] [Full Text] [Related]
18. An implant-transfer technique without impression material.
Assunção WG; Gomes EA; Aparecida Delben J; dos-Santos PH; Ricardo Barão VA; Tabata LF
J Craniofac Surg; 2010 Jul; 21(4):1274-6. PubMed ID: 20613612
[TBL] [Abstract][Full Text] [Related]
19. Accuracy of implant impression techniques.
Assif D; Marshak B; Schmidt A
Int J Oral Maxillofac Implants; 1996; 11(2):216-22. PubMed ID: 8666454
[TBL] [Abstract][Full Text] [Related]
20. A method for fabrication of implant-supported fixed partial dentures.
Zafiropoulos GG; Hoffmann O; Deli G
J Oral Implantol; 2014 Jun; 40(3):271-9. PubMed ID: 24914913
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]