These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 15119614)

  • 1. Removing nonlinearity of a homodyne interferometer by adjusting the gains of its quadrature detector systems.
    Keem T; Gonda S; Misumi I; Huang Q; Kurosawa T
    Appl Opt; 2004 Apr; 43(12):2443-8. PubMed ID: 15119614
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simple, real-time method for removing the cyclic error of a homodyne interferometer with a quadrature detector system.
    Keem T; Gonda S; Misumi I; Huang Q; Kurosawa T
    Appl Opt; 2005 Jun; 44(17):3492-8. PubMed ID: 16007847
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Homodyne laser interferometer involving minimal quadrature phase error to obtain subnanometer nonlinearity.
    Cui J; He Z; Jiu Y; Tan J; Sun T
    Appl Opt; 2016 Sep; 55(25):7086-92. PubMed ID: 27607285
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Realization of a robust homodyne quadrature laser interferometer by performing wave plate yawing to realize ultra-low error sensitivity.
    Cui J; He Z; Tan J; Sun T
    Opt Express; 2016 Oct; 24(20):23505-23518. PubMed ID: 27828413
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Compensation for the variable cyclic error in homodyne laser interferometers.
    Hu P; Zhu J; Guo X; Tan J
    Sensors (Basel); 2015 Jan; 15(2):3090-106. PubMed ID: 25647739
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A passive method to compensate nonlinearity in a homodyne interferometer.
    Ahn J; Kim JA; Kang CS; Kim JW; Kim S
    Opt Express; 2009 Dec; 17(25):23299-308. PubMed ID: 20052256
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nonlinearity of Pancharatnam's geometric phase in polarizing interferometers.
    Hils B; Dultz W; Martienssen W
    Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics; 1999 Aug; 60(2 Pt B):2322-9. PubMed ID: 11970029
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optimization of displacement-measuring quadrature interferometers considering the real properties of optical components.
    Požar T; Gregorčič P; Možina J
    Appl Opt; 2011 Mar; 50(9):1210-9. PubMed ID: 21460992
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quadrature phase-shift error analysis using a homodyne laser interferometer.
    Gregorcic P; Pozar T; Mozina J
    Opt Express; 2009 Aug; 17(18):16322-31. PubMed ID: 19724631
    [TBL] [Abstract][Full Text] [Related]  

  • 10. DC-offset-free homodyne interferometer and its nonlinearity compensation.
    Hu P; Zhu J; Zhai X; Tan J
    Opt Express; 2015 Apr; 23(7):8399-408. PubMed ID: 25968679
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pulsed entanglement measured by parametric amplifier assisted homodyne detection.
    Li J; Liu Y; Huo N; Cui L; Feng C; Ou ZY; Li X
    Opt Express; 2019 Oct; 27(21):30552-30562. PubMed ID: 31684300
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sub-nanometer periodic nonlinearity error in absolute distance interferometers.
    Yang H; Huang K; Hu P; Zhu P; Tan J; Fan Z
    Rev Sci Instrum; 2015 May; 86(5):053103. PubMed ID: 26026510
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Measurement Method for Nonlinearity in Heterodyne Laser Interferometers Based on Double-Channel Quadrature Demodulation.
    Fu H; Ji R; Hu P; Wang Y; Wu G; Tan J
    Sensors (Basel); 2018 Aug; 18(9):. PubMed ID: 30135415
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of imperfect homodyne visibility on multi-spatial-mode two-mode squeezing measurements.
    Gupta P; Speirs RW; Jones KM; Lett PD
    Opt Express; 2020 Jan; 28(1):652-664. PubMed ID: 32118988
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Highly thermal-stable heterodyne interferometer with minimized periodic nonlinearity.
    Fu H; Wu G; Hu P; Ji R; Tan J; Ding X
    Appl Opt; 2018 Feb; 57(6):1463-1467. PubMed ID: 29469849
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Nonlinearity error in homodyne interferometer caused by multi-order Doppler frequency shift ghost reflections.
    Hu P; Wang Y; Fu H; Zhu J; Tan J
    Opt Express; 2017 Feb; 25(4):3605-3612. PubMed ID: 28241573
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Homodyne interferometry with quadrature fringe detection for absolute gravimeter.
    Svitlov S; Araya A
    Appl Opt; 2014 Jun; 53(16):3548-55. PubMed ID: 24922433
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prism-pair interferometry by homodyne interferometers with a common light source for high-accuracy measurement of the absolute refractive index of glasses.
    Hori Y; Hirai A; Minoshima K
    Appl Opt; 2011 Mar; 50(8):1190-6. PubMed ID: 21394191
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Real-time normalization and nonlinearity evaluation methods of the PGC-arctan demodulation in an EOM-based sinusoidal phase modulating interferometer.
    Zhang S; Chen B; Yan L; Xu Z
    Opt Express; 2018 Jan; 26(2):605-616. PubMed ID: 29401943
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Balanced-path homodyne I/Q-interferometer scheme with very simple optical arrangement using a polarizing beam displacer.
    Eang SH; Cho K
    Opt Express; 2017 Apr; 25(7):8237-8244. PubMed ID: 28380938
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.