These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 15122151)

  • 1. The Tuckahoe knot: a secure locking slip knot.
    Wiley WB; Goradia VK
    Arthroscopy; 2004 May; 20(5):556-9. PubMed ID: 15122151
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cyclic load and failure behavior of arthroscopic knots and high strength sutures.
    Barber FA; Herbert MA; Beavis RC
    Arthroscopy; 2009 Feb; 25(2):192-9. PubMed ID: 19171280
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Security of knots tied with ethibond, fiberwire, orthocord, or ultrabraid.
    Ilahi OA; Younas SA; Ho DM; Noble PC
    Am J Sports Med; 2008 Dec; 36(12):2407-14. PubMed ID: 18827068
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Arthroscopic knots: determining the optimal balance of loop security and knot security.
    Lo IK; Burkhart SS; Chan KC; Athanasiou K
    Arthroscopy; 2004 May; 20(5):489-502. PubMed ID: 15122139
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical characteristics of 10 arthroscopic knots.
    Hassinger SM; Wongworawat MD; Hechanova JW
    Arthroscopy; 2006 Aug; 22(8):827-32. PubMed ID: 16904578
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A biomechanical comparison of arthroscopic sliding and sliding-locking knots.
    Elkousy HA; Sekiya JK; Stabile KJ; McMahon PJ
    Arthroscopy; 2005 Feb; 21(2):204-10. PubMed ID: 15689871
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Arthroscopic sliding knot: how many additional half-hitches are really needed?
    Kim SH; Yoo JC; Wang JH; Choi KW; Bae TS; Lee CY
    Arthroscopy; 2005 Apr; 21(4):405-11. PubMed ID: 15800519
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The arthroscopic square knot: a biomechanical comparison with open and arthroscopic knots.
    Elkousy H; Hammerman SM; Edwards TB; Warnock KM; O'Connor DP; Ambrose C; Meyers D; Gartsman GM
    Arthroscopy; 2006 Jul; 22(7):736-41. PubMed ID: 16843809
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Effect of Different Combinations of Three Stacked Half-Hitches and Suture Materials on an Arthroscopic Knot in a Dry or Wet Environment.
    Chong AC; Ochs JL; Zackula RE; MacFadden LN; Prohaska DJ
    Iowa Orthop J; 2018; 38():79-86. PubMed ID: 30104928
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison and performance characteristics of 3 different knots when tied with 2 suture materials used for shoulder arthroscopy.
    Mahar AT; Moezzi DM; Serra-Hsu F; Pedowitz RA
    Arthroscopy; 2006 Jun; 22(6):614.e1-2. PubMed ID: 16762698
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The SMC knot--a new slip knot with locking mechanism.
    Kim SH; Ha KI
    Arthroscopy; 2000; 16(5):563-5. PubMed ID: 10882457
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of knot security and loop security in arthroscopic knots tied with newer high-strength suture materials.
    Lo IK; Ochoa E; Burkhart SS
    Arthroscopy; 2010 Sep; 26(9 Suppl):S120-6. PubMed ID: 20810086
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical characteristics of 9 arthroscopic knots.
    Dahl KA; Patton DJ; Dai Q; Wongworawat MD
    Arthroscopy; 2010 Jun; 26(6):813-8. PubMed ID: 20511040
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The giant knot: a new one-way self-locking secured arthroscopic slip knot.
    Fleega BA; Sokkar SH
    Arthroscopy; 1999 May; 15(4):451-2. PubMed ID: 10355723
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The PC knot: a secure and satisfying arthroscopic slip knot.
    Pallia CS
    Arthroscopy; 2003; 19(5):558-60. PubMed ID: 12724688
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The triad knot: a new sliding self-locking knot.
    Yiannakopoulos CK; Hiotis I; Antonogiannakis E
    Arthroscopy; 2005 Jul; 21(7):899. PubMed ID: 16012511
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Strength of Resistance to "Flip" the Tightened Half-Hitches of an Arthroscopic Knot.
    Chong AC; Pichetsurnthorn P; Prohaska DJ
    Iowa Orthop J; 2017; 37():95-99. PubMed ID: 28852342
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Arthroscopic suture material and knot type: an updated biomechanical analysis.
    Swan KG; Baldini T; McCarty EC
    Am J Sports Med; 2009 Aug; 37(8):1578-85. PubMed ID: 19470946
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Mid-Ship knot: a new simple and secure sliding knot.
    Balg F; Boileau P
    Knee Surg Sports Traumatol Arthrosc; 2007 Feb; 15(2):217-8. PubMed ID: 16821078
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of knot security in continuous intradermal wound closures.
    Richey ML; Roe SC
    J Surg Res; 2005 Feb; 123(2):284-8. PubMed ID: 15680391
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.