These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 1513132)

  • 1. CAD-design, stress analysis and in vitro evaluation of three leaflet blood-pump valves.
    Knierbein B; Rosarius N; Unger A; Reul H; Rau G
    J Biomed Eng; 1992 Jul; 14(4):275-86. PubMed ID: 1513132
    [TBL] [Abstract][Full Text] [Related]  

  • 2. New methods for the development of pneumatic displacement pumps for cardiac assist.
    Knierbein B; Rosarius N; Reul H; Rau G
    Int J Artif Organs; 1990 Nov; 13(11):751-9. PubMed ID: 2089014
    [TBL] [Abstract][Full Text] [Related]  

  • 3. VAD Biomer blood sacs: mechanical tests and ultrastructural observations.
    Bedini R; Chistolini P; De Angelis G; Formisano G; Caiazza S
    Med Prog Technol; 1993; 19(2):83-8. PubMed ID: 8107668
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of mechanical loading of a trileaflet polyurethane blood pump valve by finite element analysis.
    Knierbein B; Mohr-Matuschek U; Rechlin M; Reul H; Rau G; Michaeli W
    Int J Artif Organs; 1990 May; 13(5):307-15. PubMed ID: 2365486
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of open leaflet geometry on the haemodynamic flow characteristics of polyurethane trileaflet artificial heart valves.
    Corden J; David T; Fisher J
    Proc Inst Mech Eng H; 1996; 210(4):273-87. PubMed ID: 9046188
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro determination of the curvatures and bending strains acting on the leaflets of polyurethane trileaflet heart valves during leaflet motion.
    Corden J; David T; Fisher J
    Proc Inst Mech Eng H; 1995; 209(4):243-53. PubMed ID: 8907218
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of the curvatures and bending strains in open trileaflet heart valves.
    Corden J; David T; Fisher J
    Proc Inst Mech Eng H; 1995; 209(2):121-8. PubMed ID: 7495427
    [TBL] [Abstract][Full Text] [Related]  

  • 8. New polyurethane heart valve prosthesis: design, manufacture and evaluation.
    Mackay TG; Wheatley DJ; Bernacca GM; Fisher AC; Hindle CS
    Biomaterials; 1996 Oct; 17(19):1857-63. PubMed ID: 8889065
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Blood compatible polyurethane elastomers.
    Szycher M; Griffin JC; Williams JL; McMenamy JP; Stagg D
    J Biomater Appl; 1987 Oct; 2(2):290-313. PubMed ID: 3504974
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the inner-surface morphology of an artificial heart by acoustic microscopy.
    Saijo Y; Okawai H; Sasaki H; Yambe T; Nitta S; Tanaka M; Kobayashi K; Honda Y
    Artif Organs; 2000 Jan; 24(1):64-9. PubMed ID: 10677159
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thermedics' approach to ventricular support systems.
    Szycher M; Clay W; Gernes D; Sherman C
    J Biomater Appl; 1986 Jul; 1(1):39-105. PubMed ID: 3333398
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative analysis of ventricular assist devices (POLVAD and POLVAD_EXT) based on multiscale FEM model.
    Milenin A; Kopernik M
    Acta Bioeng Biomech; 2011; 13(2):13-23. PubMed ID: 21761807
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A small pulsatile blood pump for ventricular support during end-stage heart failure.
    Förster F; Kaufmann R; Reul H; Rau G
    Artif Organs; 2000 May; 24(5):373-6. PubMed ID: 10848678
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Italian Artificial Heart Program.
    Mambrito B; Arabia M; Chieco S; Ferrazzi P; Ferri E; Fierli M; Glauber M; Meli M; Zagara M
    Artif Organs; 1994 Jul; 18(7):533-6. PubMed ID: 7980099
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Polyurethane heart valve durability: effects of leaflet thickness and material.
    Bernacca GM; Mackay TG; Gulbransen MJ; Donn AW; Wheatley DJ
    Int J Artif Organs; 1997 Jun; 20(6):327-31. PubMed ID: 9259209
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A newly designed jellyfish valve for an artificial heart blood pump.
    Imachi K; Fujimasa I; Mabuchi K; Chinzei T; Abe Y; Maeda K; Imanishi K; Kouno A; Ono T; Atsumi K
    ASAIO Trans; 1988; 34(3):726-8. PubMed ID: 3196591
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Totally implantable artificial hearts and left ventricular assist devices: selecting impermeable polycarbonate urethane to manufacture ventricles.
    Yang M; Zhang Z; Hahn C; Laroche G; King MW; Guidoin R
    J Biomed Mater Res; 1999; 48(1):13-23. PubMed ID: 10029144
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fatigue and hemocompatibility of polymer materials.
    Sevastianov VI; Parfeev VM
    Artif Organs; 1987 Feb; 11(1):20-5. PubMed ID: 3566579
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The influence of manufacturing methods on the function and performance of a synthetic leaflet heart valve.
    Leat ME; Fisher J
    Proc Inst Mech Eng H; 1995; 209(1):65-9. PubMed ID: 7669122
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Microtextured materials for circulatory support devices: preliminary studies.
    Zapanta CM; Griffith JW; Hess GD; Doxtater BJ; Khalapyan T; Pae WE; Rosenberg G
    ASAIO J; 2006; 52(1):17-23. PubMed ID: 16436885
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.