395 related articles for article (PubMed ID: 15132503)
1. Spatio-temporal cortical source imaging of brain electrical activity by means of time-varying parametric projection filter.
Hori J; Aiba M; He B
IEEE Trans Biomed Eng; 2004 May; 51(5):768-77. PubMed ID: 15132503
[TBL] [Abstract][Full Text] [Related]
2. A physiologically plausible spatio-temporal model for EEG signals recorded with intracerebral electrodes in human partial epilepsy.
Cosandier-Rimélé D; Badier JM; Chauvel P; Wendling F
IEEE Trans Biomed Eng; 2007 Mar; 54(3):380-8. PubMed ID: 17355049
[TBL] [Abstract][Full Text] [Related]
3. An equivalent current source model and laplacian weighted minimum norm current estimates of brain electrical activity.
He B; Yao D; Lian J; Wu D
IEEE Trans Biomed Eng; 2002 Apr; 49(4):277-88. PubMed ID: 11942719
[TBL] [Abstract][Full Text] [Related]
4. Estimation of the effective and functional human cortical connectivity with structural equation modeling and directed transfer function applied to high-resolution EEG.
Astolfi L; Cincotti F; Mattia D; Salinari S; Babiloni C; Basilisco A; Rossini PM; Ding L; Ni Y; He B; Marciani MG; Babiloni F
Magn Reson Imaging; 2004 Dec; 22(10):1457-70. PubMed ID: 15707795
[TBL] [Abstract][Full Text] [Related]
5. Subspace projection filters for real-time brain electromagnetic imaging.
Congedo M
IEEE Trans Biomed Eng; 2006 Aug; 53(8):1624-34. PubMed ID: 16916097
[TBL] [Abstract][Full Text] [Related]
6. Cortical dipole imaging of movement-related potentials by means of parametric inverse filters incorporating with signal and noise covariance.
Hori J; Miwa T; Ohshima T; He B
Methods Inf Med; 2007; 46(2):242-6. PubMed ID: 17347764
[TBL] [Abstract][Full Text] [Related]
7. Model selection in spatio-temporal electromagnetic source analysis.
Waldorp LJ; Huizenga HM; Nehorai A; Grasman RP; Molenaar PC
IEEE Trans Biomed Eng; 2005 Mar; 52(3):414-20. PubMed ID: 15759571
[TBL] [Abstract][Full Text] [Related]
8. Effect of measurement noise and electrode density on the spatial resolution of cortical potential distribution with different resistivity values for the skull.
Ryynänen OR; Hyttinen JA; Malmivuo JA
IEEE Trans Biomed Eng; 2006 Sep; 53(9):1851-8. PubMed ID: 16941841
[TBL] [Abstract][Full Text] [Related]
9. Bayesian spatio-temporal approach for EEG source reconstruction: conciliating ECD and distributed models.
Daunizeau J; Mattout J; Clonda D; Goulard B; Benali H; Lina JM
IEEE Trans Biomed Eng; 2006 Mar; 53(3):503-16. PubMed ID: 16532777
[TBL] [Abstract][Full Text] [Related]
10. Standardized shrinking LORETA-FOCUSS (SSLOFO): a new algorithm for spatio-temporal EEG source reconstruction.
Liu H; Schimpf PH; Dong G; Gao X; Yang F; Gao S
IEEE Trans Biomed Eng; 2005 Oct; 52(10):1681-91. PubMed ID: 16235654
[TBL] [Abstract][Full Text] [Related]
11. The effect of mutual information on independent component analysis in EEG/MEG analysis: a simulation study.
Neumann A; Grosse-Wentrup M; Buss M; Gramann K
Int J Neurosci; 2008 Nov; 118(11):1534-46. PubMed ID: 18853332
[TBL] [Abstract][Full Text] [Related]
12. Estimation of cortical dipole sources by equivalent dipole layer imaging and independent component analysis.
Aoki N; Hori J; He B
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():992-5. PubMed ID: 17945613
[TBL] [Abstract][Full Text] [Related]
13. Estimation of the cortical connectivity by high-resolution EEG and structural equation modeling: simulations and application to finger tapping data.
Astolfi L; Cincotti F; Babiloni C; Carducci F; Basilisco A; Rossini PM; Salinari S; Mattia D; Cerutti S; Dayan DB; Ding L; Ni Y; He B; Babiloni F
IEEE Trans Biomed Eng; 2005 May; 52(5):757-68. PubMed ID: 15887525
[TBL] [Abstract][Full Text] [Related]
14. Anatomically constrained dipole adjustment (ANACONDA) for accurate MEG/EEG focal source localizations.
Im CH; Jung HK; Fujimaki N
Phys Med Biol; 2005 Oct; 50(20):4931-53. PubMed ID: 16204881
[TBL] [Abstract][Full Text] [Related]
15. Multiregion bicentric-spheres models of the head for the simulation of bioelectric phenomena.
Vatta F; Bruno P; Inchingolo P
IEEE Trans Biomed Eng; 2005 Mar; 52(3):384-9. PubMed ID: 15759568
[TBL] [Abstract][Full Text] [Related]
16. Cortical potential imaging of brain electrical activity by means of parametric projection filter.
Hori J; Lian J; He B
Methods Inf Med; 2004; 43(1):66-9. PubMed ID: 15026840
[TBL] [Abstract][Full Text] [Related]
17. Task-based comparison of inverse methods in magnetoencephalography.
Küçükaltun-Yildirim E; Pantazis D; Leahy RM
IEEE Trans Biomed Eng; 2006 Sep; 53(9):1783-93. PubMed ID: 16941834
[TBL] [Abstract][Full Text] [Related]
18. Equivalent dipole source imaging of brain electric activity by means of parametric projection filter.
Hori J; He B
Ann Biomed Eng; 2001 May; 29(5):436-45. PubMed ID: 11400724
[TBL] [Abstract][Full Text] [Related]
19. Efficient localization of synchronous EEG source activities using a modified RAP-MUSIC algorithm.
Liu H; Schimpf PH
IEEE Trans Biomed Eng; 2006 Apr; 53(4):652-61. PubMed ID: 16602571
[TBL] [Abstract][Full Text] [Related]
20. [Multiple dipole source localization from spatio-temporal EEG data by Quasi-Newton-ICA method].
Zou L; Zhu S; He B
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Dec; 23(6):1206-12. PubMed ID: 17228710
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]