BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 15138670)

  • 1. Reproducibility of the respiratory dead space measurements in mechanically ventilated children using the CO2SMO monitor.
    Riou Y; Leclerc F; Neve V; Dupuy L; Noizet O; Leteurtre S; Sadik A
    Intensive Care Med; 2004 Jul; 30(7):1461-7. PubMed ID: 15138670
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of Bohr and Enghoff Dead Space Equations in Mechanically Ventilated Children.
    Bourgoin P; Baudin F; Brossier D; Emeriaud G; Wysocki M; Jouvet P
    Respir Care; 2017 Apr; 62(4):468-474. PubMed ID: 28223465
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Monitoring Dead Space in Mechanically Ventilated Children: Volumetric Capnography Versus Time-Based Capnography.
    Bhalla AK; Rubin S; Newth CJ; Ross P; Morzov R; Soto-Campos G; Khemani R
    Respir Care; 2015 Nov; 60(11):1548-55. PubMed ID: 26199451
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of two different methods for physiologic dead space measurements in ventilated dogs in a clinical setting.
    Mosing M; Staub L; Moens Y
    Vet Anaesth Analg; 2010 Sep; 37(5):393-400. PubMed ID: 20712605
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of volumetric capnography and mixed expired gas methods to calculate physiological dead space in mechanically ventilated ICU patients.
    Sinha P; Soni N
    Intensive Care Med; 2012 Oct; 38(10):1712-7. PubMed ID: 22893221
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Predicting dead space ventilation in critically ill patients using clinically available data.
    Frankenfield DC; Alam S; Bekteshi E; Vender RL
    Crit Care Med; 2010 Jan; 38(1):288-91. PubMed ID: 19789453
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Higher Dead Space Is Associated With Increased Mortality in Critically Ill Children.
    Bhalla AK; Belani S; Leung D; Newth CJ; Khemani RG
    Crit Care Med; 2015 Nov; 43(11):2439-45. PubMed ID: 26200768
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of different methods for dead space measurements in ventilated newborns using CO2-volume plot.
    Wenzel U; Wauer RR; Schmalisch G
    Intensive Care Med; 1999 Jul; 25(7):705-13. PubMed ID: 10470574
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of dead-space ventilation in patients with acute respiratory distress syndrome: a prospective observational study.
    Doorduin J; Nollet JL; Vugts MP; Roesthuis LH; Akankan F; van der Hoeven JG; van Hees HW; Heunks LM
    Crit Care; 2016 May; 20(1):121. PubMed ID: 27145818
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calculation of physiologic dead space: comparison of ventilator volumetric capnography to measurements by metabolic analyzer and volumetric CO2 monitor.
    Siobal MS; Ong H; Valdes J; Tang J
    Respir Care; 2013 Jul; 58(7):1143-51. PubMed ID: 23232740
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Large difference between Enghoff and Bohr dead space in ventilated infants with hypoxemic respiratory failure.
    Zuiki M; Kume R; Matsuura A; Mitsuno K; Kitamura K; Kanayama T; Komatsu H
    Pediatr Pulmonol; 2021 Jul; 56(7):2102-2107. PubMed ID: 33866691
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Respiratory deadspace measurements in neonates during extracorporeal membrane oxygenation.
    Arnold JH; Thompson JE; Benjamin PK
    Crit Care Med; 1993 Dec; 21(12):1895-900. PubMed ID: 8252895
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of alveolar dead-space, shunt and V/Q distribution on respiratory dead-space measurements.
    Tang Y; Turner MJ; Baker AB
    Br J Anaesth; 2005 Oct; 95(4):538-48. PubMed ID: 16126784
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Volume Capnography in the Intensive Care Unit: Physiological Principles, Measurements, and Calculations.
    Kreit JW
    Ann Am Thorac Soc; 2019 Mar; 16(3):291-300. PubMed ID: 30657700
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new equal area method to calculate and represent physiologic, anatomical, and alveolar dead spaces.
    Tang Y; Turner MJ; Baker AB
    Anesthesiology; 2006 Apr; 104(4):696-700. PubMed ID: 16571964
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of physiologic deadspace measurement in intubated pediatric patients using a metabolic monitor: comparison with the Douglas bag method.
    Lum L; Saville A; Venkataraman ST
    Crit Care Med; 1998 Apr; 26(4):760-4. PubMed ID: 9559616
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques.
    Balogh AL; Petak F; Fodor GH; Tolnai J; Csorba Z; Babik B
    Br J Anaesth; 2016 Jul; 117(1):109-17. PubMed ID: 27317710
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical use of volumetric capnography in mechanically ventilated patients.
    Kremeier P; Böhm SH; Tusman G
    J Clin Monit Comput; 2020 Feb; 34(1):7-16. PubMed ID: 31152285
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prognostic value of different dead space indices in mechanically ventilated patients with acute lung injury and ARDS.
    Lucangelo U; Bernabè F; Vatua S; Degrassi G; Villagrà A; Fernandez R; Romero PV; Saura P; Borelli M; Blanch L
    Chest; 2008 Jan; 133(1):62-71. PubMed ID: 17989165
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validity of sidestream endtidal carbon dioxide measurement in critically ill, mechanically ventilated children.
    van der Heijden HH; Truin GJ; Verhaeg J; van der Pol P; Lemson J
    Paediatr Anaesth; 2016 Mar; 26(3):294-9. PubMed ID: 26714621
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]