221 related articles for article (PubMed ID: 15143805)
1. Mueller polarimetric imaging system with liquid crystals.
Laude-Boulesteix B; De Martino A; Drévillon B; Schwartz L
Appl Opt; 2004 May; 43(14):2824-32. PubMed ID: 15143805
[TBL] [Abstract][Full Text] [Related]
2. Fiber-based polarization-sensitive Mueller matrix optical coherence tomography with continuous source polarization modulation.
Jiao S; Todorović M; Stoica G; Wang LV
Appl Opt; 2005 Sep; 44(26):5463-7. PubMed ID: 16161660
[TBL] [Abstract][Full Text] [Related]
3. Improved scanning laser fundus imaging using polarimetry.
Bueno JM; Hunter JJ; Cookson CJ; Kisilak ML; Campbell MC
J Opt Soc Am A Opt Image Sci Vis; 2007 May; 24(5):1337-48. PubMed ID: 17429479
[TBL] [Abstract][Full Text] [Related]
4. Ex vivo characterization of normal and adenocarcinoma colon samples by Mueller matrix polarimetry.
Ahmad I; Ahmad M; Khan K; Ashraf S; Ahmad S; Ikram M
J Biomed Opt; 2015 May; 20(5):56012. PubMed ID: 26021717
[TBL] [Abstract][Full Text] [Related]
5. Rotating orthogonal polarization imaging.
Morgan SP; Zhu Q; Stockford IM; Crowe JA
Opt Lett; 2008 Jul; 33(13):1503-5. PubMed ID: 18594679
[TBL] [Abstract][Full Text] [Related]
6. Acousto-optic-tunable-filter-based spectropolarimetric imagers for medical diagnostic applications--instrument design point of view.
Gupta N
J Biomed Opt; 2005; 10(5):051802. PubMed ID: 16292960
[TBL] [Abstract][Full Text] [Related]
7. Design, testing, and clinical studies of a handheld polarized light camera.
Ramella-Roman JC; Lee K; Prahl SA; Jacques SL
J Biomed Opt; 2004; 9(6):1305-10. PubMed ID: 15568952
[TBL] [Abstract][Full Text] [Related]
8. 256-channel magnetic imaging system.
da Silva FC; Halloran ST; Kos AB; Pappas DP
Rev Sci Instrum; 2008 Jan; 79(1):013709. PubMed ID: 18248041
[TBL] [Abstract][Full Text] [Related]
9. Compensation of polarization-dependent loss in transmission fiber gratings by use of a Sagnac loop interferometer.
Kim CS; Choi B; Nelson JS; Li Q; Dashti PZ; Lee HP
Opt Lett; 2005 Jan; 30(1):20-2. PubMed ID: 15648624
[TBL] [Abstract][Full Text] [Related]
10. Single-photon imaging at 20,000 frames/s.
Zappa F; Tisa S; Cova S; Maccagnani P; Saletti R; Roncella R
Opt Lett; 2005 Nov; 30(22):3024-6. PubMed ID: 16315709
[TBL] [Abstract][Full Text] [Related]
11. Double-pass axially resolved confocal Mueller matrix imaging polarimetry.
Lara D; Dainty C
Opt Lett; 2005 Nov; 30(21):2879-81. PubMed ID: 16279456
[TBL] [Abstract][Full Text] [Related]
12. Polarization microscopy by use of digital holography: application to optical-fiber birefringence measurements.
Colomb T; Dürr F; Cuche E; Marquet P; Limberger HG; Salathé RP; Depeursinge C
Appl Opt; 2005 Jul; 44(21):4461-9. PubMed ID: 16047894
[TBL] [Abstract][Full Text] [Related]
13. Adapted polarization state contrast image.
Richert M; Orlik X; De Martino A
Opt Express; 2009 Aug; 17(16):14199-210. PubMed ID: 19654831
[TBL] [Abstract][Full Text] [Related]
14. Polarization anisotropy in fiber-optic second harmonic generation microscopy.
Fu L; Gu M
Opt Express; 2008 Mar; 16(7):5000-6. PubMed ID: 18542600
[TBL] [Abstract][Full Text] [Related]
15. Development of a parallel detection and processing system using a multidetector array for wave field restoration in scanning transmission electron microscopy.
Taya M; Matsutani T; Ikuta T; Saito H; Ogai K; Harada Y; Tanaka T; Takai Y
Rev Sci Instrum; 2007 Aug; 78(8):083705. PubMed ID: 17764327
[TBL] [Abstract][Full Text] [Related]
16. Determination of collagen fiber orientation in histological slides using Mueller microscopy and validation by second harmonic generation imaging.
Bancelin S; Nazac A; Ibrahim BH; Dokládal P; Decencière E; Teig B; Haddad H; Fernandez H; Schanne-Klein MC; De Martino A
Opt Express; 2014 Sep; 22(19):22561-74. PubMed ID: 25321725
[TBL] [Abstract][Full Text] [Related]
17. Effect of speckle on APSCI method and Mueller Imaging.
Upadhyay D; Richert M; Lacot E; De Martino A; Orlik X
Opt Express; 2011 Feb; 19(5):4553-9. PubMed ID: 21369287
[TBL] [Abstract][Full Text] [Related]
18. Integrated spectral-polarization imaging sensor with aluminum nanowire polarization filters.
Kulkarni M; Gruev V
Opt Express; 2012 Oct; 20(21):22997-3012. PubMed ID: 23188263
[TBL] [Abstract][Full Text] [Related]
19. A camera-based input device for large interactive displays.
Morrison GD
IEEE Comput Graph Appl; 2005; 25(4):52-7. PubMed ID: 16060574
[No Abstract] [Full Text] [Related]
20. Imaging polarimetry for high throughput chiral screening.
Gibbs PR; Uehara CS; Nguyen PT; Willson RC
Biotechnol Prog; 2003; 19(4):1329-34. PubMed ID: 12892498
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]