These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
24. Alternating atrial pacing cycle length during ventricular tachycardia: what is the mechanism? Almehairi M; Somani R; Michael KA; Baranchuk A Heart Rhythm; 2013 Oct; 10(10):1553-5. PubMed ID: 23721945 [No Abstract] [Full Text] [Related]
25. Twiddler's syndrome in a patient with CRT-D device - A case report. Bhatt DD; Gupta RK; Kaul U Indian Heart J; 2015; 67(6):592-4. PubMed ID: 26702694 [TBL] [Abstract][Full Text] [Related]
26. Biventricular implantable cardioverter defibrillator use in a patient with heart failure and ventricular tachycardia secondary to Emery-Dreifuss syndrome. Walker S; Levy T; Rex S; Paul VE Europace; 1999 Jul; 1(3):206-9. PubMed ID: 11225801 [TBL] [Abstract][Full Text] [Related]
27. [Twiddler's syndrome in a patient with implantable cardioverter defibrillator: an avoidable complication?]. Larrouse E; Rodríguez E; Moya A A; Rodríguez O; Soler Soler J Rev Esp Cardiol; 2001 Dec; 54(12):1456-8. PubMed ID: 11754794 [TBL] [Abstract][Full Text] [Related]
28. An uncommon twist on Twiddler's syndrome. Ali RG; Navaravong L; Cui J; Stoenescu M Conn Med; 2012 Feb; 76(2):81-3. PubMed ID: 22670357 [TBL] [Abstract][Full Text] [Related]
31. "Spontaneous Twiddler's" Syndrome: The Importance of the Device Shape. Gul EE; Boles U; Haseeb S; Glover B; Simpson C; Baranchuk A; Michael K Pacing Clin Electrophysiol; 2017 Mar; 40(3):326-329. PubMed ID: 27859379 [TBL] [Abstract][Full Text] [Related]
32. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator. Khoo C; Bennett M; Chakrabarti S; LeMaitre J; Tung SK Can J Cardiol; 2013 Feb; 29(2):254.e5-7. PubMed ID: 22902157 [TBL] [Abstract][Full Text] [Related]
33. Inappropriate detection and therapy from an implantable cardioverter defibrillator due to atrial undersensing. Paraskevaidis S; Polymeropoulos K; Vassilikos V; Louridas G Pacing Clin Electrophysiol; 2005 Sep; 28(9):1002-4. PubMed ID: 16176546 [TBL] [Abstract][Full Text] [Related]
34. Absent ventricular tachycardia detection in a biventricular implantable cardioverter-defibrillator due to intradevice interaction with a rate smoothing pacing algorithm. Cooper JM; Sauer WH; Verdino RJ Heart Rhythm; 2004 Dec; 1(6):728-31. PubMed ID: 15851247 [TBL] [Abstract][Full Text] [Related]
35. Use of an antimicrobial pouch/envelope in the treatment of Twiddler's syndrome. Osoro M; Lorson W; Hirsh JB; Mahlow WJ Pacing Clin Electrophysiol; 2018 Feb; 41(2):136-142. PubMed ID: 29266324 [TBL] [Abstract][Full Text] [Related]
36. [Complication after implantable cardioverter defibrillator implantation: report of 1 case]. Lou ZY; Zhou MH; Li XQ Di Yi Jun Yi Da Xue Xue Bao; 2005 Mar; 25(3):360. PubMed ID: 15803642 [No Abstract] [Full Text] [Related]
37. Twiddler's Syndrome Combined With Subclavian Crush Syndrome: A Case of ICD Lead Failure and Potential Challenging Lead Extraction. Quinto L; Testolina M; Zanon F; Migliore F J Invasive Cardiol; 2019 Nov; 31(11):E340. PubMed ID: 31671067 [TBL] [Abstract][Full Text] [Related]
38. Lead failure caused by twiddler's syndrome in subpectorally implanted unipolar single-lead cardioverter-defibrillators. Mewis C; Kühlkamp V; Dörnberger V; Kalighi K; Seipel L J Thorac Cardiovasc Surg; 1997 Dec; 114(6):1121-2. PubMed ID: 9434709 [No Abstract] [Full Text] [Related]
39. Implantation of a biventricular implantable cardioverter defibrillator via the femoral vein. Jourdier L; Swinburn J; Roberts D; Clague J Pacing Clin Electrophysiol; 2007 Apr; 30(4):571-2. PubMed ID: 17437585 [TBL] [Abstract][Full Text] [Related]
40. Inappropriate sensing of pectoral myopotentials by an implantable cardioverter defibrillator system. Karanam S; John RM Pacing Clin Electrophysiol; 2004 May; 27(5):688-9. PubMed ID: 15125734 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]