BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 15147013)

  • 1. Improvement of depth position in 2-D/3-D registration of knee implants using single-plane fluoroscopy.
    Yamazaki T; Watanabe T; Nakajima Y; Sugamoto K; Tomita T; Yoshikawa H; Tamura S
    IEEE Trans Med Imaging; 2004 May; 23(5):602-12. PubMed ID: 15147013
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images.
    Mahfouz MR; Hoff WA; Komistek RD; Dennis DA
    IEEE Trans Med Imaging; 2003 Dec; 22(12):1561-74. PubMed ID: 14649746
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy evaluation of fluoroscopy-based 2D and 3D pose reconstruction with unicompartmental knee arthroplasty.
    Van Duren BH; Pandit H; Beard DJ; Murray DW; Gill HS
    Med Eng Phys; 2009 Apr; 31(3):356-63. PubMed ID: 18606555
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Total knee arthroplasty three-dimensional kinematic estimation prevision. From a two-dimensional fluoroscopy acquired dynamic model.
    Lebel BP; Pineau V; Gouzy SL; Geais L; Parienti JJ; Dutheil JJ; Vielpeau CH
    Orthop Traumatol Surg Res; 2011 Apr; 97(2):111-20. PubMed ID: 21439928
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A volumetric model-based 2D to 3D registration method for measuring kinematics of natural knees with single-plane fluoroscopy.
    Tsai TY; Lu TW; Chen CM; Kuo MY; Hsu HC
    Med Phys; 2010 Mar; 37(3):1273-84. PubMed ID: 20384265
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of single-plane fluoroscopy in determining relative position and orientation of total knee replacement components.
    Acker S; Li R; Murray H; John PS; Banks S; Mu S; Wyss U; Deluzio K
    J Biomech; 2011 Feb; 44(4):784-7. PubMed ID: 21092967
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of the position and orientation of artificial knee implants using markers embedded in a bone: preliminary in vitro experiments.
    Imai S; Higashijima K; Ishida A; Fukuoka Y; Hoshino A; Minamitani H
    Med Eng Phys; 2003 Jun; 25(5):419-24. PubMed ID: 12711240
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An optimized image matching method for determining in-vivo TKA kinematics with a dual-orthogonal fluoroscopic imaging system.
    Bingham J; Li G
    J Biomech Eng; 2006 Aug; 128(4):588-95. PubMed ID: 16813450
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 3D kinematics of mobile-bearing total knee arthroplasty using X-ray fluoroscopy.
    Yamazaki T; Futai K; Tomita T; Sato Y; Yoshikawa H; Tamura S; Sugamoto K
    Int J Comput Assist Radiol Surg; 2015 Apr; 10(4):487-95. PubMed ID: 24965187
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detecting femur-insert collisions to improve precision of fluoroscopic knee arthroplasty analysis.
    Prins AH; Kaptein BL; Stoel BC; Reiber JH; Valstar ER
    J Biomech; 2010 Mar; 43(4):694-700. PubMed ID: 20004899
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new multi-modal similarity measure for fast gradient-based 2D-3D image registration.
    Pickering MR; Muhit AA; Scarvell JM; Smith PN
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():5821-4. PubMed ID: 19965251
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A model-based method for the reconstruction of total knee replacement kinematics.
    Zuffi S; Leardini A; Catani F; Fantozzi S; Cappello A
    IEEE Trans Med Imaging; 1999 Oct; 18(10):981-91. PubMed ID: 10628957
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Development of three-dimensional kinematic analysis system for artificial knee implants using X-ray fluoroscopic imaging].
    Yamazaki T; Watanabe T; Nakajima Y; Sugamoto K; Tomita T; Maeda D; Sato Y; Yoshikawa H; Tamura S
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2005 Jan; 61(1):79-87. PubMed ID: 15682035
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty.
    Argenson JN; Scuderi GR; Komistek RD; Scott WN; Kelly MA; Aubaniac JM
    J Biomech; 2005 Feb; 38(2):277-84. PubMed ID: 15598454
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of segmentation errors on 3D-to-2D registration of implant models in X-ray images.
    Mahfouz MR; Hoff WA; Komistek RD; Dennis DA
    J Biomech; 2005 Feb; 38(2):229-39. PubMed ID: 15598449
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy.
    Fregly BJ; Rahman HA; Banks SA
    J Biomech Eng; 2005 Aug; 127(4):692-9. PubMed ID: 16121540
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated image registration for assessing three-dimensional alignment of entire lower extremity and implant position using bi-plane radiography.
    Kobayashi K; Sakamoto M; Tanabe Y; Ariumi A; Sato T; Omori G; Koga Y
    J Biomech; 2009 Dec; 42(16):2818-22. PubMed ID: 19766224
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Advancements in total knee arthroplasty kinematics: 3D implant computer aided design model creation through X-ray or fluoroscopic images.
    Nguyen VD; LaCour MT; Dessinger GM; Komistek RD
    Clin Biomech (Bristol, Avon); 2023 Oct; 109():106091. PubMed ID: 37696164
    [TBL] [Abstract][Full Text] [Related]  

  • 19. New registration algorithm for determining 3D knee kinematics using CT and single-plane fluoroscopy with improved out-of-plane translation accuracy.
    Scarvell JM; Pickering MR; Smith PN
    J Orthop Res; 2010 Mar; 28(3):334-40. PubMed ID: 19798739
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new model-based RSA method validated using CAD models and models from reversed engineering.
    Kaptein BL; Valstar ER; Stoel BC; Rozing PM; Reiber JH
    J Biomech; 2003 Jun; 36(6):873-82. PubMed ID: 12742455
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.