BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

2447 related articles for article (PubMed ID: 15151096)

  • 1. [Long-term results of the Schenker cementless femoral component].
    Dzupa V; Cech O; Sesták M; Klézl Z
    Acta Chir Orthop Traumatol Cech; 2004; 71(2):93-100. PubMed ID: 15151096
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Evaluation of results after reimplantation of total hip arthroplasty cemented cup].
    Dzupa V; Cech O; Pacovský V; Pazdírek P
    Acta Chir Orthop Traumatol Cech; 2004; 71(1):31-6. PubMed ID: 15069860
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Reconstruction of the acetabulum during replacement of the aseptically loosened polyethylene cup].
    Koudela K; Malotín T
    Acta Chir Orthop Traumatol Cech; 2001; 68(3):162-7. PubMed ID: 11706538
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Early aseptic loosening of the CF 30 femoral stem].
    Kovanda M; Havlícek V; Hudec J
    Acta Chir Orthop Traumatol Cech; 2007 Feb; 74(1):59-64. PubMed ID: 17331456
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The uncemented self-threading Ultima cup: first 5 years' experience].
    Pazdírek P; Bartonícek J; Dzupa V
    Acta Chir Orthop Traumatol Cech; 2001; 68(1):24-30. PubMed ID: 11706711
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Long-term experience with the combined ARBOND hydroxyapatite coating in implant osteointegration].
    Landor I; Vavrík P; Jahoda D; Pokorný D; Ballay R; Sosna A
    Acta Chir Orthop Traumatol Cech; 2009 Jun; 76(3):172-8. PubMed ID: 19595277
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Revision of total hip replacement operations at the Orthopedic Clinic IPVZ in Prague, 1999].
    Stĕdrý V; Dungl P; Hajný P
    Acta Chir Orthop Traumatol Cech; 2001; 68(1):18-23. PubMed ID: 11706710
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Personal experience with the Wagner revision stem in hip joint reoperations].
    Cech O; Stehlík J; Krbec M; Vrecion V
    Acta Chir Orthop Traumatol Cech; 2001; 68(3):148-61. PubMed ID: 11706537
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Straight femoral taper in cementless primary total hip replacement in less than 65 year-old patients: multicenter study of 115 consecutive implantations at mean 8,2 year follow-up].
    Bonnomet F; Delaunay C; Simon P; Lefebvre Y; Clavert P; Kapandji AI; Kempf JF
    Rev Chir Orthop Reparatrice Appar Mot; 2001 Dec; 87(8):802-14. PubMed ID: 11845084
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Complications with the acetabular cup in the CLS total hip joint endoprosthesis].
    Rozkydal Z; Janícek P; Deduch J; Hudecek F
    Acta Chir Orthop Traumatol Cech; 2001; 68(2):85-92. PubMed ID: 11706722
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Surgical therapy of osteolysis around stable cementless hip arthroplasty].
    Spicka J; Gallo J; Cechová I; Kamínek P; Mikulík J
    Acta Chir Orthop Traumatol Cech; 2005; 72(4):228-34. PubMed ID: 16194441
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Results of the Evora dual-mobility socket after a minimum follow-up of five years.
    Leclercq S; Benoit JY; de Rosa JP; Euvrard P; Leteurtre C; Girardin P
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Dec; 94(8):e17-22. PubMed ID: 19070709
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [An evaluation of the methods used for removal of components and cement in revision hip arthroplasty].
    Erdemli B
    Acta Orthop Traumatol Turc; 2004; 38(3):188-94. PubMed ID: 15347918
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Should monobloc cemented stems be systematically revised during revision total hip arthroplasty? A prospective evaluation].
    Grosjean G; Courpied JP; Moindreau M; Hunou N; Mathieu M; Hamadouche M
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Nov; 94(7):670-7. PubMed ID: 18984124
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Femoral reconstruction with endosteal bone allografts protected by a metallic mesh in reoperation of total hip prosthesis. 19 cases with an average follow-up of 83 months].
    Migaud H; Jardin C; Fontaine C; Pierchon F; d'Herbomez O; Duquennoy A
    Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(4):360-7. PubMed ID: 9452810
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mode of loosening of matt-finished femoral stems in primary total hip replacement.
    Behairy YM; Harris WH
    Saudi Med J; 2002 Oct; 23(10):1187-94. PubMed ID: 12436120
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Oblong acetabular cup, type TC, for revision total hip arthroplasty].
    Trč T; Stastný E
    Acta Chir Orthop Traumatol Cech; 2012; 79(6):506-11. PubMed ID: 23286682
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Good survival of uncemented tapered stems for failed intertrochanteric osteotomy: a mean 16 year follow-up study in 45 patients.
    Parsch D; Jung AW; Thomsen M; Ewerbeck V; Aldinger PR
    Arch Orthop Trauma Surg; 2008 Oct; 128(10):1081-5. PubMed ID: 17876593
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Resection hip arthroplasty--mid- and long-term results].
    Hudec T; Jahoda D; Sosna A
    Acta Chir Orthop Traumatol Cech; 2005; 72(5):287-92. PubMed ID: 16316603
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Experience with non-cemented stems in Schenker hip prosthesis].
    Stĕdrý V; Slavík M
    Acta Chir Orthop Traumatol Cech; 1993; 60(5):284-6. PubMed ID: 8285006
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 123.