BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

211 related articles for article (PubMed ID: 15156105)

  • 1. Changes in the contact area during the bedding-in wear of different sizes of metal on metal hip prostheses.
    Hu XQ; Isaac GH; Fisher J
    Biomed Mater Eng; 2004; 14(2):145-9. PubMed ID: 15156105
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication.
    Mabuchi K; Sakai R; Ota M; Ujihira M
    Clin Biomech (Bristol, Avon); 2004 May; 19(4):362-9. PubMed ID: 15109756
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Contact mechanics and elastohydrodynamic lubrication in a novel metal-on-metal hip implant with an aspherical bearing surface.
    Meng Q; Gao L; Liu F; Yang P; Fisher J; Jin Z
    J Biomech; 2010 Mar; 43(5):849-57. PubMed ID: 20003978
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Bionic surface design in metal on metal bearings for total hip arthroplasty--optimization of tribological characteristics].
    Böhling U; Scholz J; Thomas W; Grundei H
    Biomed Tech (Berl); 2005 Apr; 50(4):119-23. PubMed ID: 15884709
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [FE-analysis of surface stresses for the tribological system in total hip prostheses].
    Behrens BA; Helms G; Pösse O; Nolte I; Meyer-Lindenberg A; Rittmann P; Windhagen H; Pressel T
    Biomed Tech (Berl); 2006 Dec; 51(5-6):367-70. PubMed ID: 17155874
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of head size on wear properties of metal-on-metal bearings of hip prostheses, and comparison with wear properties of metal-on-polyethylene bearings using hip simulator.
    Okazaki Y
    J Mech Behav Biomed Mater; 2014 Mar; 31():152-63. PubMed ID: 24290355
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Geometric element analysis of fretting in a model of a modular femoral component of a hip implant.
    Lewis G
    Biomed Mater Eng; 2004; 14(1):43-51. PubMed ID: 14757952
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin Z; Roberts P; Grigoris P
    J Biomech; 2007; 40(6):1340-9. PubMed ID: 16824529
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Importance of head diameter, clearance, and cup wall thickness in elastohydrodynamic lubrication analysis of metal-on-metal hip resurfacing prostheses.
    Liu F; Jin Z; Roberts P; Grigoris P
    Proc Inst Mech Eng H; 2006 Aug; 220(6):695-704. PubMed ID: 16961189
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of 3D physiological loading and motion on elastohydrodynamic lubrication of metal-on-metal total hip replacements.
    Gao L; Wang F; Yang P; Jin Z
    Med Eng Phys; 2009 Jul; 31(6):720-9. PubMed ID: 19269879
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design aspects of compliant, soft layer bearings for an experimental hip prosthesis.
    Scholes SC; Unsworth A; Blamey JM; Burgess IC; Jones E; Smith N
    Proc Inst Mech Eng H; 2005; 219(2):79-87. PubMed ID: 15819479
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of contact mechanics in McKee-farrar metal-on-metal hip implants.
    Yew A; Jagatia M; Ensaff H; Jin ZM
    Proc Inst Mech Eng H; 2003; 217(5):333-40. PubMed ID: 14558645
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transient elastohydrodynamic lubrication analysis of metal-on-metal hip implant under simulated walking conditions.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    J Biomech; 2006; 39(5):905-14. PubMed ID: 16199048
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A finite element method comparison of wear in two metal-on-metal total hip prostheses.
    Cosmi F; Hoglievina M; Fancellu G; Martinelli B
    Proc Inst Mech Eng H; 2006 Nov; 220(8):871-9. PubMed ID: 17236520
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Loss in mechanical contact of cementless acetabular prostheses due to post-operative weight bearing: a biomechanical model.
    Bellini CM; Galbusera F; Ceroni RG; Raimondi MT
    Med Eng Phys; 2007 Mar; 29(2):175-81. PubMed ID: 16569508
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Finite element simulation of early creep and wear in total hip arthroplasty.
    Bevill SL; Bevill GR; Penmetsa JR; Petrella AJ; Rullkoetter PJ
    J Biomech; 2005 Dec; 38(12):2365-74. PubMed ID: 16214484
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Contact mechanics analysis of metal-on-metal hip resurfacing prostheses.
    Udofia IJ; Yew A; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(5):293-305. PubMed ID: 15532995
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants.
    Kang L; Galvin AL; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 2006 Jan; 220(1):33-46. PubMed ID: 16459444
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of elastohydrodynamic lubrication in McKee-Farrar metal-on-metal hip joint replacement.
    Yew A; Udofia I; Jagatia M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):27-34. PubMed ID: 14982343
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Friction moments of large metal-on-metal hip joint bearings and other modern designs.
    Bishop NE; Waldow F; Morlock MM
    Med Eng Phys; 2008 Oct; 30(8):1057-64. PubMed ID: 18291702
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.