105 related articles for article (PubMed ID: 15156513)

  • 1. Hemolysis as a factor in clinical chemistry and hematology of the dog.
    O'Neill SL; Feldman BF
    Vet Clin Pathol; 1989; 18(3):58-68. PubMed ID: 15156513
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of hemolysis on serum chemistry analytes in ratites.
    Andreasen CB; Andreasen JR; Thomas JS
    Vet Clin Pathol; 1997; 26(4):165-171. PubMed ID: 12658578
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: determination of allowable interference limits according to different calculation methods.
    Monneret D; Mestari F; Atlan G; Corlouer C; Ramani Z; Jaffre J; Dever S; Fressart V; Alkouri R; Lamari F; Devilliers C; Imbert-Bismut F; Bonnefont-Rousselot D
    Scand J Clin Lab Invest; 2015 Apr; 75(2):162-9. PubMed ID: 25608598
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Handling of hemolyzed serum samples in clinical chemistry laboratories: the Nordic hemolysis project.
    Gidske G; Aakre KM; Rustad P; Sandberg S; Norling A; Pelanti J; Henriksen G; Thorsteinsdottir I; Kristensen GBB
    Clin Chem Lab Med; 2019 Oct; 57(11):1699-1711. PubMed ID: 31617690
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of hemolysis on routine clinical chemistry testing.
    Lippi G; Salvagno GL; Montagnana M; Brocco G; Guidi GC
    Clin Chem Lab Med; 2006; 44(3):311-6. PubMed ID: 16519604
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessing the influence of true hemolysis occurring in patient samples on emergency clinical biochemistry tests results using the VITROS
    Liu S; Li J; Ning L; Wu D; Wei D
    Biomed Rep; 2021 Nov; 15(5):91. PubMed ID: 34631046
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of hemolysis index thresholds for biochemical tests on Siemens Advia 2400 chemistry analyzer.
    Du Z; Liu J; Zhang H; Bao B; Zhao R; Jin Y
    J Clin Lab Anal; 2019 May; 33(4):e22856. PubMed ID: 30779463
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hemoglobin interference from in vivo hemolysis.
    Blank DW; Kroll MH; Ruddel ME; Elin RJ
    Clin Chem; 1985 Sep; 31(9):1566-9. PubMed ID: 4028407
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effects of in vitro hemolysis on serum biochemistry values of the bottlenose dolphin (Tursiops truncatus).
    Morgan LW; Van Bonn W; Jensen ED; Ridgway SH
    J Zoo Wildl Med; 1999 Mar; 30(1):70-5. PubMed ID: 10367646
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Establishing hemolysis and lipemia acceptance thresholds for clinical chemistry tests.
    Knezevic CE; Ness MA; Tsang PHT; Tenney BJ; Marzinke MA
    Clin Chim Acta; 2020 Nov; 510():459-465. PubMed ID: 32771484
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Hemolysis influence on twenty-two biochemical parameters measurement].
    Ali D; Sacchetto E; Dumontet E; Le Carrer D; Orsonneau JL; Delaroche O; Bigot-Corbel E
    Ann Biol Clin (Paris); 2014; 72(3):297-311. PubMed ID: 24876141
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of 0.1 and 1.0 per cent erythrocytes and hemolysis on serum chemistry values.
    Laessig RH; Hassemer DJ; Paskey TA; Schwartz TH
    Am J Clin Pathol; 1976 Oct; 66(4):639-44. PubMed ID: 970364
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of biochemical values in serum and plasma, fresh and frozen plasma, and hemolyzed samples from orange-winged Amazon parrots (Amazona amazonica).
    Hawkins MG; Kass PH; Zinkl JG; Tell LA
    Vet Clin Pathol; 2006 Jun; 35(2):219-25. PubMed ID: 16783717
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of hemolysis on plasma electrolyte and chemistry values in the common green iguana (Iguana iguana).
    Benson KG; Paul-Murphy J; MacWilliams P
    J Zoo Wildl Med; 1999 Sep; 30(3):413-5. PubMed ID: 10572866
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Sex-specific reference intervals of hematologic and biochemical analytes in Sprague-Dawley rats using the nonparametric rank percentile method.
    He Q; Su G; Liu K; Zhang F; Jiang Y; Gao J; Liu L; Jiang Z; Jin M; Xie H
    PLoS One; 2017; 12(12):e0189837. PubMed ID: 29261747
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The degree of acceptability of swine blood values at increasing levels of hemolysis evaluated through visual inspection versus automated quantification.
    Di Martino G; Stefani AL; Lippi G; Gagliazzo L; McCormick W; Gabai G; Bonfanti L
    J Vet Diagn Invest; 2015 May; 27(3):306-12. PubMed ID: 26038480
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hematology and chemistry reference values for free-ranging harbor seals (Phoca vitulina) and the effects of hemolysis on chemistry values of captive harbor seals.
    Morgan L; Kumaresan S; Thomas C; MacWilliams P
    J Zoo Wildl Med; 1998 Dec; 29(4):394-400. PubMed ID: 10065846
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical Laboratory Quality Practices When Hemolysis Occurs.
    Howanitz PJ; Lehman CM; Jones BA; Meier FA; Horowitz GL
    Arch Pathol Lab Med; 2015 Jul; 139(7):901-6. PubMed ID: 26125430
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Impact of Individualized Hemolysis Management Based on Biological Variation Cut-offs in a Clinical Laboratory.
    Marques-Garcia F; Jung DHH; PĂ©rez SE
    Ann Lab Med; 2022 Mar; 42(2):169-177. PubMed ID: 34635610
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of hemolysis cut-offs for biochemical and immunochemical analytes according to their value.
    Dupuy AM; Bargnoux AS; Kuster N; Cristol JP; Badiou S
    Clin Chem Lab Med; 2020 Jul; 58(8):1232-1241. PubMed ID: 32267242
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]