These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 15163790)

  • 1. An acute hypertensive episode triggered by an ambulatory blood-pressure-monitoring device.
    Yosefy C; Vaturi M; Levine RA
    N Engl J Med; 2004 May; 350(22):2315-6. PubMed ID: 15163790
    [No Abstract]   [Full Text] [Related]  

  • 2. Recommendations for devices for measuring ambulatory blood pressure based on validation evidence.
    O'Brien E
    Nefrologia; 2002; 22 Suppl 3():3-6. PubMed ID: 12014300
    [No Abstract]   [Full Text] [Related]  

  • 3. The cost-effectiveness of ambulatory blood pressure monitoring.
    Aitken L; Addison C
    Prof Nurse; 1996 Dec; 12(3):198-202. PubMed ID: 9128668
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of the Stabil-O-Graph blood pressure self-measurement device.
    Westhoff TH; Schmidt S; Zidek W; van der Giet M
    J Hum Hypertens; 2008 Mar; 22(3):233-5. PubMed ID: 17823593
    [No Abstract]   [Full Text] [Related]  

  • 5. The trained observer better predicts daytime ABPM diastolic blood pressure in hypertensive patients than does an automated (Omron) device.
    Graves JW; Grossardt BR; Gullerud RE; Bailey KR; Feldstein J
    Blood Press Monit; 2006 Apr; 11(2):53-8. PubMed ID: 16534405
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The HoMedics BPA-200 and BPA-300 home blood pressure devices fail the European Society of Hypertension International Protocol and cannot be recommended for patient use.
    Grim CE; Grim CM
    Blood Press Monit; 2008 Aug; 13(4):227-9. PubMed ID: 18635979
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of ambulatory tonometric radial arterial wave capture to measure ambulatory blood pressure: the validation of a novel wrist-bound device in adults.
    Nair D; Tan SY; Gan HW; Lim SF; Tan J; Zhu M; Gao H; Chua NH; Peh WL; Mak KH
    J Hum Hypertens; 2008 Mar; 22(3):220-2. PubMed ID: 17992251
    [No Abstract]   [Full Text] [Related]  

  • 8. Validation of the Welch Allyn Spot Vital Signs blood pressure device according to the ANSI/AAMI SP10: 2002. Accuracy and cost-efficiency successfully combined.
    Alpert BS
    Blood Press Monit; 2007 Oct; 12(5):345-7. PubMed ID: 17890975
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Therapy refractory arterial hypertension].
    Gürke T
    Praxis (Bern 1994); 1998 Nov; 87(48):1662-3. PubMed ID: 9881041
    [No Abstract]   [Full Text] [Related]  

  • 10. The role of behavioral factors in white coat and sustained hypertension.
    Pickering TG; Devereux RB; Gerin W; James GD; Pieper C; Schlussel YR; Schnall PL
    J Hypertens Suppl; 1990 Dec; 8(7):S141-7. PubMed ID: 2095382
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Apparatus for home monitoring of pregnant hypertensive patients.
    Hon EH; Fukushima T; Berumen M; Vargas N
    J Matern Fetal Med; 1996; 5(1):45-9. PubMed ID: 8796767
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Can an electronic device with a single cuff be accurate in a wide range of arm size? Validation of the Visomat Comfort 20/40 device for home blood pressure monitoring.
    Stergiou GS; Tzamouranis D; Nasothimiou EG; Protogerou AD
    J Hum Hypertens; 2008 Nov; 22(11):796-800. PubMed ID: 18596720
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Evaluation of the accuracy of arterial pressure measurements with different types of devices used for self-monitoring].
    Bołtuć J; Grzywna R; Paprzycki P; Marczewski K
    Wiad Lek; 1996; 49(1-6):3-9. PubMed ID: 9173653
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Omron HEM-711 DLX home Blood pressure monitor passes the European Society of Hypertension International Validation Protocol.
    Grim CE; Grim CM
    Blood Press Monit; 2008 Aug; 13(4):225-6. PubMed ID: 18635978
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Focus on masked workplace hypertension: the next step for perfect 24-hour blood pressure control.
    Uno H; Kario K
    Hypertens Res; 2006 Dec; 29(12):937-40. PubMed ID: 17378364
    [No Abstract]   [Full Text] [Related]  

  • 16. Psychosocial determinants of hypertension: laboratory and field models.
    Gerin W; James GD
    Blood Press Monit; 2010 Apr; 15(2):93-9. PubMed ID: 20220517
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated blood pressure measurement for diagnosing hypertension.
    Myers MG
    Blood Press Monit; 2007 Dec; 12(6):405-6. PubMed ID: 18277322
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Are there really differences between home and daytime ambulatory blood pressure? Comparison using a novel dual-mode ambulatory and home monitor.
    Stergiou GS; Tzamouranis D; Nasothimiou EG; Karpettas N; Protogerou A
    J Hum Hypertens; 2010 Mar; 24(3):207-12. PubMed ID: 19609285
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of the HONSUN LD-578 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.
    Zhang Y; Wang J; Huang QF; Sheng CS; Li Y; Wang JG
    Blood Press Monit; 2009 Jun; 14(3):128-31. PubMed ID: 19454866
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the SCHILLER BR-102 plus noninvasive ambulatory blood pressure monitor according to the International Protocol introduced by the Working Group on Blood Pressure Monitoring of the European Society of Hypertension.
    Denchev SV; Simova II; Matveev MG
    Blood Press Monit; 2007 Oct; 12(5):329-33. PubMed ID: 17890972
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.