These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

307 related articles for article (PubMed ID: 15167024)

  • 1. Aerodynamics, voice quality, and laryngeal image analysis of normal and pathologic voices.
    Yumoto E
    Curr Opin Otolaryngol Head Neck Surg; 2004 Jun; 12(3):166-73. PubMed ID: 15167024
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Three-dimensional characteristics of the larynx with immobile vocal fold.
    Yumoto E; Oyamada Y; Nakano K; Nakayama Y; Yamashita Y
    Arch Otolaryngol Head Neck Surg; 2004 Aug; 130(8):967-74. PubMed ID: 15313868
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flexible Fiber-Optic High-Speed Imaging of Vocal Fold Vibration: A Preliminary Report.
    Woo P; Baxter P
    J Voice; 2017 Mar; 31(2):175-181. PubMed ID: 28325351
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multiparametric analysis of vocal fold vibrations in healthy and disordered voices in high-speed imaging.
    Inwald EC; Döllinger M; Schuster M; Eysholdt U; Bohr C
    J Voice; 2011 Sep; 25(5):576-90. PubMed ID: 20728308
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Reinke edema--helpful in unilateral recurrent laryngeal nerve paralysis?].
    Kothe C; Schade G; Fleischer S; Hess M
    HNO; 2003 Oct; 51(10):833-5. PubMed ID: 14523539
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantitative Analysis of Vocal Fold Vibration in Vocal Fold Paralysis With the Use of High-speed Digital Imaging.
    Yamauchi A; Yokonishi H; Imagawa H; Sakakibara KI; Nito T; Tayama N
    J Voice; 2016 Nov; 30(6):766.e13-766.e22. PubMed ID: 26652777
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A portable high-speed camera system for vocal fold examinations.
    Hertegård S; Larsson H
    J Voice; 2014 Nov; 28(6):681-7. PubMed ID: 25008381
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Imaging and Analysis of Human Vocal Fold Vibration Using Two-Dimensional (2D) Scanning Videokymography.
    Park HJ; Cha W; Kim GH; Jeon GR; Lee BJ; Shin BJ; Choi YG; Wang SG
    J Voice; 2016 May; 30(3):345-53. PubMed ID: 26239969
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-time dual visualization of two different modalities for the evaluation of vocal fold vibration - Laryngeal videoendoscopy and 2D scanning videokymography: Preliminary report.
    Kim GH; Wang SG; Lee BJ; Park HJ; Kim YC; Kim HS; Sohn KT; Kwon SB
    Auris Nasus Larynx; 2017 Apr; 44(2):174-181. PubMed ID: 27421819
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Visual and Automatic Evaluation of Vocal Fold Mucosal Waves Through Sharpness of Lateral Peaks in High-Speed Videokymographic Images.
    Kumar SP; Phadke KV; Vydrová J; Novozámský A; Zita A; Zitová B; Švec JG
    J Voice; 2020 Mar; 34(2):170-178. PubMed ID: 30314931
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Relationship between 3D behavior of the unilaterally paralyzed larynx and aerodynamic vocal function.
    Yumoto E; Nakano K; Oyamada Y
    Acta Otolaryngol; 2003 Jan; 123(2):274-8. PubMed ID: 12701757
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Vocal fold vibration irregularities caused by different types of laryngeal asymmetry.
    Eysholdt U; Rosanowski F; Hoppe U
    Eur Arch Otorhinolaryngol; 2003 Sep; 260(8):412-7. PubMed ID: 12690514
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High-speed Imaging of Vocal Fold Vibration Onset Delay: Normal Versus Abnormal.
    Woo P
    J Voice; 2017 May; 31(3):307-312. PubMed ID: 27836428
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Phasegram Analysis of Vocal Fold Vibration Documented With Laryngeal High-speed Video Endoscopy.
    Herbst CT; Unger J; Herzel H; Švec JG; Lohscheller J
    J Voice; 2016 Nov; 30(6):771.e1-771.e15. PubMed ID: 26879075
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Real-time Simultaneous DKG and 2D DKG Using High-speed Digital Camera.
    Kang DH; Wang SG; Park HJ; Lee JC; Jeon GR; Choi IS; Kim SJ; Shin BJ
    J Voice; 2017 Mar; 31(2):247.e1-247.e7. PubMed ID: 27839706
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative assessment of videolaryngostroboscopic images in patients with glottic pathologies.
    Niebudek-Bogusz E; Kopczynski B; Strumillo P; Morawska J; Wiktorowicz J; Sliwinska-Kowalska M
    Logoped Phoniatr Vocol; 2017 Jul; 42(2):73-83. PubMed ID: 27132636
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Laryngeal mechanisms during human 4-kHz vocalization studied with CT, videostroboscopy, and color Doppler imaging.
    Tsai CG; Shau YW; Liu HM; Hsiao TY
    J Voice; 2008 May; 22(3):275-82. PubMed ID: 17509826
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Glottal configuration in unilaterally paralyzed larynx and vocal function.
    Yumoto E; Sanuki T; Minoda R; Kumai Y; Nishimoto K
    Acta Otolaryngol; 2013 Feb; 133(2):187-93. PubMed ID: 23145918
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A generalized procedure for analyzing sustained and dynamic vocal fold vibrations from laryngeal high-speed videos using phonovibrograms.
    Unger J; Schuster M; Hecker DJ; Schick B; Lohscheller J
    Artif Intell Med; 2016 Jan; 66():15-28. PubMed ID: 26597002
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Vibration parameter extraction from endoscopic image series of the vocal folds.
    Döllinger M; Hoppe U; Hettlich F; Lohscheller J; Schuberth S; Eysholdt U
    IEEE Trans Biomed Eng; 2002 Aug; 49(8):773-81. PubMed ID: 12148815
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.