  • 21. A strategy for high-throughput analysis of levosimendan and its metabolites in human plasma samples using sequential negative and positive ionization liquid chromatography/tandem mass spectrometric detection.
    Zhang J; Gage EM; Ji QC; El-Shourbagy TA
    Rapid Commun Mass Spectrom; 2007; 21(14):2169-76. PubMed ID: 17631672
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Simultaneous determination of a selective adenosine 2A agonist, BMS-068645, and its acid metabolite in human plasma by liquid chromatography-tandem mass spectrometry--evaluation of the esterase inhibitor, diisopropyl fluorophosphate, in the stabilization of a labile ester-containing drug.
    Zeng J; Onthank D; Crane P; Unger S; Zheng N; Pasas-Farmer S; Arnold M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):77-84. PubMed ID: 17280881
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A liquid chromatography--tandem mass spectrometry multiresidue method for quantification of specific metabolites of organophosphorus pesticides, synthetic pyrethroids, selected herbicides, and deet in human urine.
    Olsson AO; Baker SE; Nguyen JV; Romanoff LC; Udunka SO; Walker RD; Flemmen KL; Barr DB
    Anal Chem; 2004 May; 76(9):2453-61. PubMed ID: 15117183
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Quantitation of tadalafil in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionization.
    Ramakrishna NV; Vishwottam KN; Puran S; Koteshwara M; Manoj S; Santosh M; Chidambara J; Wishu S; Sumatha B
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Oct; 809(2):243-9. PubMed ID: 15315772
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A new approach to the effective preparation of plasma samples for rapid drug quantitation using on-line solid phase extraction mass spectrometry.
    Ding J; Neue UD
    Rapid Commun Mass Spectrom; 1999; 13(21):2151-9. PubMed ID: 10523774
    [TBL] [Abstract][Full Text] [Related]  

  • 26. High-throughput quantitation of nefazodone and its metabolites in human plasma by high flow direct-injection LC-MS/MS.
    Mao Y; Huang MQ; Xia YQ; Jemal M
    J Pharm Biomed Anal; 2007 Apr; 43(5):1808-19. PubMed ID: 17236738
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Quantitation of Armillarisin A in human plasma by liquid chromatography-electrospray tandem mass spectrometry.
    Wang Y; Wang Y; Li P; Tang Y; Fawcett JP; Gu J
    J Pharm Biomed Anal; 2007 Apr; 43(5):1860-3. PubMed ID: 17250987
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A monolithic-phase based on-line extraction approach for determination of pharmaceutical components in human plasma by HPLC-MS/MS and a comparison with liquid-liquid extraction.
    Naxing Xu R; Fan L; Kim GE; El-Shourbagy TA
    J Pharm Biomed Anal; 2006 Feb; 40(3):728-36. PubMed ID: 16289933
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Microdose clinical trial: quantitative determination of fexofenadine in human plasma using liquid chromatography/electrospray ionization tandem mass spectrometry.
    Yamane N; Tozuka Z; Sugiyama Y; Tanimoto T; Yamazaki A; Kumagai Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Oct; 858(1-2):118-28. PubMed ID: 17804306
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Development and validation of a selective and robust LC-MS/MS method for high-throughput quantifying rizatriptan in small plasma samples: application to a clinical pharmacokinetic study.
    Chen Y; Miao H; Lin M; Fan G; Hong Z; Wu H; Wu Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Dec; 844(2):268-77. PubMed ID: 16899417
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Rapid quantitative analysis of oxiracetam in human plasma by liquid chromatography/electrospray tandem mass spectrometry.
    Son J; Lee J; Lee M; Lee E; Lee KT; La S; Kim DH
    J Pharm Biomed Anal; 2004 Sep; 36(1):183-7. PubMed ID: 15351064
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Parallel ultra-high flow rate liquid chromatography with mass spectrometric detection using a multiplex electrospray source for direct, sensitive determination of pharmaceuticals in plasma at extremely high throughput.
    Bayliss MK; Little D; Mallett DN; Plumb RS
    Rapid Commun Mass Spectrom; 2000; 14(21):2039-45. PubMed ID: 11085416
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A general screening method for doping agents in human urine by solid phase extraction and liquid chromatography/time-of-flight mass spectrometry.
    Kolmonen M; Leinonen A; Pelander A; Ojanperä I
    Anal Chim Acta; 2007 Feb; 585(1):94-102. PubMed ID: 17386652
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Potentials of ion trap collisional spectrometry for liquid chromatography/electrospray ionization tandem mass spectrometry determination of buprenorphine and nor-buprenorphine in urine, blood and hair samples.
    Favretto D; Frison G; Vogliardi S; Ferrara SD
    Rapid Commun Mass Spectrom; 2006; 20(8):1257-65. PubMed ID: 16550495
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A 96-well single-pot protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of muraglitazar, a novel diabetes drug, in human plasma.
    Xue YJ; Liu J; Pursley J; Unger S
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Feb; 831(1-2):213-22. PubMed ID: 16388995
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Simultaneous determination of rosuvastatin and fenofibric acid in human plasma by LC-MS/MS with electrospray ionization: assay development, validation and application to a clinical study.
    Trivedi RK; Kallem RR; Mullangi R; Srinivas NR
    J Pharm Biomed Anal; 2005 Sep; 39(3-4):661-9. PubMed ID: 15970417
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Determination of Cloretazine (VNP40101M) and its active metabolite (VNP4090CE) in human plasma by liquid chromatography electrospray tandem mass spectrometry (LC-ESI-MS/MS).
    Bai F; Minkin P; Fraga CH; O'Shaughnessy MA; Gururangan S; Stewart CF
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 853(1-2):97-104. PubMed ID: 17446145
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Determination of a novel gamma-secretase inhibitor in human plasma and cerebrospinal fluid using automated 96 well solid phase extraction and liquid chromatography/tandem mass spectrometry.
    Matthews CZ; Woolf EJ
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Feb; 863(1):36-45. PubMed ID: 18249589
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A 96-well single-pot liquid-liquid extraction, hydrophilic interaction liquid chromatography-mass spectrometry method for the determination of muraglitazar in human plasma.
    Xue YJ; Liu J; Unger S
    J Pharm Biomed Anal; 2006 Jun; 41(3):979-88. PubMed ID: 16533587
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Determination of ranolazine in human plasma by LC-MS/MS and its application in bioequivalence study.
    Bhaumik U; Ghosh A; Sarkar AK; Bose A; Selvan PS; Sengupta P; Chakraborty US; Ghosh D; Pal TK
    J Pharm Biomed Anal; 2008 Dec; 48(5):1404-10. PubMed ID: 18986788
    [TBL] [Abstract][Full Text] [Related]  