BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 15172290)

  • 1. Clinical experience with the mini-extracorporeal circulation system: an evolution or a revolution?
    Remadi JP; Marticho P; Butoi I; Rakotoarivelo Z; Trojette F; Benamar A; Beloucif S; Foure D; Poulain HJ
    Ann Thorac Surg; 2004 Jun; 77(6):2172-5; discussion 2176. PubMed ID: 15172290
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prospective randomized study comparing coronary artery bypass grafting with the new mini-extracorporeal circulation Jostra System or with a standard cardiopulmonary bypass.
    Remadi JP; Rakotoarivelo Z; Marticho P; Benamar A
    Am Heart J; 2006 Jan; 151(1):198. PubMed ID: 16368318
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Combined coronary artery bypass grafting and aortic valve replacement with minimal extracorporeal closed circuit circulation versus standard cardiopulmonary bypass.
    Yilmaz A; Sjatskig J; van Boven WJ; Waanders FG; Kelder JC; Sonker U; Kloppenburg GT
    Interact Cardiovasc Thorac Surg; 2010 Dec; 11(6):754-7. PubMed ID: 20847068
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement.
    Castiglioni A; Verzini A; Pappalardo F; Colangelo N; Torracca L; Zangrillo A; Alfieri O
    Ann Thorac Surg; 2007 Feb; 83(2):586-91. PubMed ID: 17257992
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Beating-heart coronary artery bypass grafting using a miniaturized extracorporeal circulation system.
    Reber D; Fritz M; Tossios P; Buchwald D; Lindstaedt M; Klak K; Marks P; Laczkovics A
    Heart Surg Forum; 2008; 11(5):E276-80. PubMed ID: 18948240
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: a randomized prospective trial.
    Remadi JP; Rakotoarivello Z; Marticho P; Trojette F; Benamar A; Poulain H; Tribouilloy C
    J Thorac Cardiovasc Surg; 2004 Sep; 128(3):436-41. PubMed ID: 15354105
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement: a randomized study.
    Castiglioni A; Verzini A; Colangelo N; Nascimbene S; Laino G; Alfieri O
    Interact Cardiovasc Thorac Surg; 2009 Jul; 9(1):37-41; discussion 41. PubMed ID: 19342389
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Minimal extracorporeal circulation: an alternative for on-pump and off-pump coronary revascularization.
    Puehler T; Haneya A; Philipp A; Wiebe K; Keyser A; Rupprecht L; Hirt S; Kobuch R; Diez C; Hilker M; Schmid C
    Ann Thorac Surg; 2009 Mar; 87(3):766-72. PubMed ID: 19231386
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Four years' experience with a miniaturized extracorporeal circulation system and its influence on clinical outcome.
    Wiesenack C; Liebold A; Philipp A; Ritzka M; Koppenberg J; Birnbaum DE; Keyl C
    Artif Organs; 2004 Dec; 28(12):1082-8. PubMed ID: 15554936
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Minimal versus conventional cardiopulmonary bypass: assessment of intraoperative myocardial damage in coronary bypass surgery.
    Immer FF; Pirovino C; Gygax E; Englberger L; Tevaearai H; Carrel TP
    Eur J Cardiothorac Surg; 2005 Nov; 28(5):701-4. PubMed ID: 16221550
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Totally minimized extracorporeal circulation: an important benefit for coronary artery bypass grafting in Jehovah's witnesses.
    Vaislic C; Bical O; Farge C; Gaillard D; Ponzio O; Ollivier Y; Abdelmoumen Y; Robine B; Souffrant G; Bouharaoua T
    Heart Surg Forum; 2003; 6(5):307-10. PubMed ID: 14721799
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Minimal extracorporeal circulation and off-pump compared to conventional cardiopulmonary bypass in coronary surgery.
    Panday GF; Fischer S; Bauer A; Metz D; Schubel J; El Shouki N; Eberle T; Hausmann H
    Interact Cardiovasc Thorac Surg; 2009 Nov; 9(5):832-6. PubMed ID: 19671581
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Arrested coronary artery bypass grafting with modified percutaneous cardiopulmonary support circuit (mini-pump system)].
    Takai H; Eishi K
    Kyobu Geka; 2006 Jul; 59(8 Suppl):625-30. PubMed ID: 16910505
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prospective randomized comparison of coronary bypass grafting with minimal extracorporeal circulation system (MECC) versus off-pump coronary surgery.
    Mazzei V; Nasso G; Salamone G; Castorino F; Tommasini A; Anselmi A
    Circulation; 2007 Oct; 116(16):1761-7. PubMed ID: 17875971
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Minimal extracorporeal circulation is a promising technique for coronary artery bypass grafting.
    Immer FF; Ackermann A; Gygax E; Stalder M; Englberger L; Eckstein FS; Tevaearai HT; Schmidli J; Carrel TP
    Ann Thorac Surg; 2007 Nov; 84(5):1515-20; discussion 1521. PubMed ID: 17954055
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mini-cardiopulmonary bypass system: results of a prospective randomized study.
    Beghi C; Nicolini F; Agostinelli A; Borrello B; Budillon AM; Bacciottini F; Friggeri M; Costa A; Belli L; Battistelli L; Gherli T
    Ann Thorac Surg; 2006 Apr; 81(4):1396-400. PubMed ID: 16564279
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Early experience with the minimal extracorporeal circulation system (MECC) during thoracoabdominal aortic aneurysm repair.
    Palombo D; Valenti D; Gaggiano A; Lupo M; Borin P
    Eur J Vasc Endovasc Surg; 2004 Mar; 27(3):324-6. PubMed ID: 14760604
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Coronary artery bypass surgery using the mini-extracorporeal circulation system: a Spanish unit's experience].
    Zamora E; Delgado L; Castro MA; Fernández M; Orrit J; Romero B; Cámara ML; Ruyra X
    Rev Esp Cardiol; 2008 Apr; 61(4):376-81. PubMed ID: 18405518
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Miniaturized cardiopulmonary bypass and acute kidney injury in coronary artery bypass graft surgery.
    Benedetto U; Luciani R; Goracci M; Capuano F; Refice S; Angeloni E; Roscitano A; Sinatra R
    Ann Thorac Surg; 2009 Aug; 88(2):529-35. PubMed ID: 19632407
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimal access aortic valve replacement using a minimal extracorporeal circulatory system.
    Yilmaz A; Rehman A; Sonker U; Kloppenburg GT
    Ann Thorac Surg; 2009 Mar; 87(3):720-5. PubMed ID: 19231379
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.