These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 15172290)

  • 41. Initial experience with a minimized extracorporeal bypass system: is there a clinical benefit?
    Abdel-Rahman U; Ozaslan F; Risteski PS; Martens S; Moritz A; Al Daraghmeh A; Keller H; Wimmer-Greinecker G
    Ann Thorac Surg; 2005 Jul; 80(1):238-43. PubMed ID: 15975373
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Microbubble activity in miniaturized and in conventional extracorporeal circulation.
    Camboni D; Schmidt S; Philipp A; Rupprecht L; Haneya A; Puehler T; Arlt M; Hilker M; Schmid C
    ASAIO J; 2009; 55(1):58-62. PubMed ID: 19092669
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Beneficial effects of modern perfusion concepts in aortic valve and aortic root surgery.
    Kutschka I; Skorpil J; El Essawi A; Hajek T; Harringer W
    Perfusion; 2009 Jan; 24(1):37-44. PubMed ID: 19567547
    [TBL] [Abstract][Full Text] [Related]  

  • 44. First experiences with a new miniaturised life support system for mobile percutaneous cardiopulmonary bypass.
    Arlt M; Philipp A; Zimmermann M; Voelkel S; Hilker M; Hobbhahn J; Schmid C
    Resuscitation; 2008 Jun; 77(3):345-50. PubMed ID: 18308452
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Mini-extracorporeal circulation minimizes coagulation abnormalities and ameliorates pulmonary outcome in coronary artery bypass grafting surgery.
    Zeitani J; Buccisano F; Nardella S; Flaminio M; Prati P; Chiariello G; Venditti A; Chiariello L
    Perfusion; 2013 Jul; 28(4):298-305. PubMed ID: 23411504
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Aortic surgery using total miniaturized cardiopulmonary bypass.
    Issitt RW; Mulholland JW; Oliver MD; Yarham GJ; Borra PJ; Morrison P; Dimarakis I; Anderson JR
    Ann Thorac Surg; 2008 Aug; 86(2):627-31. PubMed ID: 18640344
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Survival of cardiorespiratory arrest after coronary artery bypass grafting or aortic valve surgery.
    Ngaage DL; Cowen ME
    Ann Thorac Surg; 2009 Jul; 88(1):64-8. PubMed ID: 19559193
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Impact of miniaturization of cardiopulmonary bypass circuit on blood transfusion requirement in neonatal open-heart surgery.
    Kotani Y; Honjo O; Nakakura M; Ugaki S; Kawabata T; Kuroko Y; Osaki S; Yoshizumi K; Kasahara S; Ishino K; Sano S
    ASAIO J; 2007; 53(6):662-5. PubMed ID: 18043142
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Mini extracorporeal circuit cardiopulmonary bypass system: a review.
    Curtis N; Vohra HA; Ohri SK
    Perfusion; 2010 May; 25(3):115-24. PubMed ID: 20581025
    [TBL] [Abstract][Full Text] [Related]  

  • 50. A propensity score analysis on the effect of eliminating cardiopulmonary bypass for coronary artery bypass grafting.
    Crescenzi G; Landoni G; Romano A; Boroli F; Giardina G; Bignami E; Fochi O; Aletti G; Rosica C; Zangrillo A
    Minerva Anestesiol; 2007 Mar; 73(3):135-41. PubMed ID: 17384571
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Coronary revascularization with extracorporeal circulation, aortic clamping or OPCAB: does the method's choice influence the results?].
    Coelho P; Gomes V; Silva ND; Fragata I; Ramos JS; Fragata J
    Rev Port Cir Cardiotorac Vasc; 2005; 12(1):15-9. PubMed ID: 15895122
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Multiple valve surgery with beating heart technique.
    Ricci M; Macedo FI; Suarez MR; Brown M; Alba J; Salerno TA
    Ann Thorac Surg; 2009 Feb; 87(2):527-31. PubMed ID: 19161773
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Mini re-sternotomy for aortic valve replacement in patients with patent coronary bypass grafts.
    Dell'Amore A; Del Giglio M; Calvi S; Pagliaro M; Fedeli C; Magnano D; Tripodi A; Lamarra M
    Interact Cardiovasc Thorac Surg; 2009 Jul; 9(1):94-7. PubMed ID: 19376803
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A closed perfusion system with heparin coating and centrifugal pump improves cardiopulmonary bypass biocompatibility in elderly patients.
    Lindholm L; Westerberg M; Bengtsson A; Ekroth R; Jensen E; Jeppsson A
    Ann Thorac Surg; 2004 Dec; 78(6):2131-8; discussion 2138. PubMed ID: 15561050
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Intraoperative red blood cell transfusion during coronary artery bypass graft surgery increases the risk of postoperative low-output heart failure.
    Surgenor SD; DeFoe GR; Fillinger MP; Likosky DS; Groom RC; Clark C; Helm RE; Kramer RS; Leavitt BJ; Klemperer JD; Krumholz CF; Westbrook BM; Galatis DJ; Frumiento C; Ross CS; Olmstead EM; O'Connor GT
    Circulation; 2006 Jul; 114(1 Suppl):I43-8. PubMed ID: 16820613
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Biocompatibility of heparin-coated cardiopulmonary bypass circuits in coronary patients with left ventricular dysfunction is superior to PMEA-coated circuits.
    Kutay V; Noyan T; Ozcan S; Melek Y; Ekim H; Yakut C
    J Card Surg; 2006; 21(6):572-7. PubMed ID: 17073955
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Is there really a clinical benefit of using minimized extracorporeal circulation for coronary artery bypass grafting?
    Schöttler J; Lutter G; Böning A; Soltau D; Bein B; Caliebe D; Haake N; Schoeneich F; Cremer J
    Thorac Cardiovasc Surg; 2008 Mar; 56(2):65-70. PubMed ID: 18278679
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Inflammatory response after coronary revascularization: off-pump versus on-pump (heparin-coated circuits and poly2methoxyethylacrylate-coated circuits).
    Hazama S; Eishi K; Yamachika S; Noguchi M; Ariyoshi T; Takai H; Odate T; Matsukuma S; Onohara D; Yanatori M
    Ann Thorac Cardiovasc Surg; 2004 Apr; 10(2):90-6. PubMed ID: 15209550
    [TBL] [Abstract][Full Text] [Related]  

  • 59. The CentriMag: a new optimized centrifugal blood pump with levitating impeller.
    Mueller JP; Kuenzli A; Reuthebuch O; Dasse K; Kent S; Zuend G; Turina MI; Lachat ML
    Heart Surg Forum; 2004; 7(5):E477-80. PubMed ID: 15802261
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Minimizing cardiopulmonary bypass attenuates myocardial damage after cardiac surgery.
    Skrabal CA; Steinhoff G; Liebold A
    ASAIO J; 2007; 53(1):32-5. PubMed ID: 17237646
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.