These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
288 related articles for article (PubMed ID: 15188796)
1. Reproducibility of the study of placental vascularization by three-dimensional power Doppler. Mercé LT; Barco MJ; Bau S J Perinat Med; 2004; 32(3):228-33. PubMed ID: 15188796 [TBL] [Abstract][Full Text] [Related]
2. Reproducibility of regional placental vascularity/perfusion measurement using 3D power Doppler. Lai PK; Wang YA; Welsh AW Ultrasound Obstet Gynecol; 2010 Aug; 36(2):202-9. PubMed ID: 20201118 [TBL] [Abstract][Full Text] [Related]
3. Placental vascular sonobiopsy using three-dimensional power Doppler ultrasound in normal and growth restricted fetuses. Noguchi J; Hata K; Tanaka H; Hata T Placenta; 2009 May; 30(5):391-7. PubMed ID: 19327824 [TBL] [Abstract][Full Text] [Related]
4. Assessment of placental vascularization by three-dimensional power Doppler "vascular biopsy" in normal pregnancies. Merce LT; Barco MJ; Bau S; Kupesic S; Kurjak A Croat Med J; 2005 Oct; 46(5):765-71. PubMed ID: 16158469 [TBL] [Abstract][Full Text] [Related]
5. Alteration of vascularization in preeclamptic placentas measured by three-dimensional power Doppler ultrasound. Chen CY; Wang KG; Chen CP J Matern Fetal Neonatal Med; 2013 Nov; 26(16):1616-22. PubMed ID: 23565968 [TBL] [Abstract][Full Text] [Related]
6. Vascularization of the placenta and the sub-placental myometrium: feasibility and reproducibility of a three-dimensional power Doppler ultrasound quantification technique. A pilot study. Morel O; Grangé G; Fresson J; Schaaps JP; Foidart JM; Cabrol D; Tsatsaris V J Matern Fetal Neonatal Med; 2011 Feb; 24(2):284-90. PubMed ID: 20476879 [TBL] [Abstract][Full Text] [Related]
7. Reproducibility of placental volume and vasculature indices obtained by 3-dimensional power Doppler sonography. Huster KM; Haas K; Schoenborn J; McVean D; Odibo AO J Ultrasound Med; 2010 Jun; 29(6):911-6. PubMed ID: 20498465 [TBL] [Abstract][Full Text] [Related]
8. Reproducibility of first trimester three-dimensional placental measurements. Cabezas López E; Martínez-Payo C; Engels Calvo V; San Frutos Llorente L; Pérez-Medina T Eur J Obstet Gynecol Reprod Biol; 2016 Jun; 201():156-60. PubMed ID: 27136382 [TBL] [Abstract][Full Text] [Related]
9. Placental three-dimensional power Doppler indices in mid-pregnancy and late pregnancy complicated by gestational diabetes mellitus. Surányi A; Kozinszky Z; Molnár A; Nyári T; Bitó T; Pál A Prenat Diagn; 2013 Oct; 33(10):952-8. PubMed ID: 23740806 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of the utero-placental circulation by three-dimensional Doppler ultrasound in the second trimester of normal pregnancy. Zalud I; Shaha S J Matern Fetal Neonatal Med; 2007 Apr; 20(4):299-305. PubMed ID: 17437237 [TBL] [Abstract][Full Text] [Related]
11. Quantitative analysis of placental vasculature by three-dimensional power Doppler ultrasonography in normal pregnancies from 12 to 40 weeks of gestation. de Paula CF; Ruano R; Campos JA; Zugaib M Placenta; 2009 Feb; 30(2):142-8. PubMed ID: 19073343 [TBL] [Abstract][Full Text] [Related]
12. A technique for the estimation of fractional moving blood volume by using three-dimensional power Doppler US. Stevenson GN; Collins SL; Welsh AW; Impey LW; Noble JA Radiology; 2015 Jan; 274(1):230-7. PubMed ID: 25117590 [TBL] [Abstract][Full Text] [Related]
13. Is three-dimensional power Doppler ultrasound useful in the assessment of placental perfusion in normal and growth-restricted pregnancies? Guiot C; Gaglioti P; Oberto M; Piccoli E; Rosato R; Todros T Ultrasound Obstet Gynecol; 2008 Feb; 31(2):171-6. PubMed ID: 18254148 [TBL] [Abstract][Full Text] [Related]
14. 3D power Doppler ultrasound in early diagnosis of preeclampsia. Neto RM; Ramos JG Pregnancy Hypertens; 2016 Jan; 6(1):10-6. PubMed ID: 26955765 [TBL] [Abstract][Full Text] [Related]
15. Are there any differences in three-dimensional placental vascular indices obtained using conventional power Doppler and high-definition flow imaging? Rizzo G; Pietrolucci ME; Aiello E; Dijmeli E; Bosi C; Arduini D J Matern Fetal Neonatal Med; 2012 Sep; 25(9):1664-7. PubMed ID: 22272917 [TBL] [Abstract][Full Text] [Related]
16. Quantitative assessment of placental vasculature and placental volume in normal pregnancies with the use of 3D Power Doppler. Pomorski M; Zimmer M; Fuchs T; Florjanski J; Pomorska M; Tomialowicz M; Milnerowicz-Nabzdyk E Adv Med Sci; 2014 Mar; 59(1):23-7. PubMed ID: 24797969 [TBL] [Abstract][Full Text] [Related]
17. Spatiotemporal image correlation-derived volumetric Doppler impedance indices from spherical samples of the placenta: intraobserver reliability and correlation with conventional umbilical artery Doppler indices. Welsh AW; Hou M; Meriki N; Martins WP Ultrasound Obstet Gynecol; 2012 Oct; 40(4):431-6. PubMed ID: 22302650 [TBL] [Abstract][Full Text] [Related]
18. Reliability of First-Trimester Ultrasonic Biopsy for the Evaluation of Placental and Myometrial Blood Perfusion and the Prediction of Preeclampsia. Markey S; Demers S; Girard M; Tétu A; Gouin K; Bujold E J Obstet Gynaecol Can; 2016 Nov; 38(11):1003-1008. PubMed ID: 27969552 [TBL] [Abstract][Full Text] [Related]
19. Three-dimensional power Doppler ultrasound evaluation of placental blood flow in normal monochorionic diamniotic twin pregnancies. Sun W; Yin S; Wei Q; Zhang Y; Yang Z; Cai A; Wang Y; Lei W BMC Pregnancy Childbirth; 2018 Nov; 18(1):443. PubMed ID: 30428855 [TBL] [Abstract][Full Text] [Related]
20. Validation of placental vascular sonobiopsy for obtaining representative placental vascular indices by three-dimensional power Doppler ultrasonography. Tuuli MG; Houser M; Odibo L; Huster K; Macones GA; Odibo AO Placenta; 2010 Mar; 31(3):192-6. PubMed ID: 20060583 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]